MAURY USCG vessel records Sign in
← All vessels

GAS HUSKY

GAS HUSKY is a tank ship. The Coast Guard has recorded 1 inspection in 2021, along with 2 deficiencies.

Records in 2021. Most recent: inspection, 23 March 2021.

Built
Not recorded
Last inspected
23 March 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9507764 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1652934
Flag
LIBERIA
—
Maury page id
psix-1652934

Inspections, by type

Years with a record 1 calendar year (2021)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5910 - Convention (Subpart B), Gross Ton
5910 - Regulatory (Subpart C or D), Gross Ton
7218 - Dead Weight, Ton
10984 - Displacement, Ton
2081 - Convention (Subpart B), Net Ton
2081 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

23 March 2021 COC-GAS Renew · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7159305

Deficiency record · 2

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 March 2021 Resolved
High pressure alarm should be activated befor the set pressures are reached. The #1 Tank pressure senseor could not be tested in order to demonstrate that it functions properly. Cargo Tank #1 is restricted from being loaded. -SOLAS 76/78 (14) VII/13.1 IGC Code (93) 13.4.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 23 March 2021
Resolved 23 March 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 March 2021 Resolved
Pressure relief valves should be set and sealed by a competent authority and a record of this action, including the values of set pressures should be retained aboard the vessel. Tank #2 aft MARV is missing a serial number and pressure setting and therefore can't be verified to match the se and seal certificates. Tank #2 is restricted from being loaded. SOLAS 76/78 (14)VII/13.1 IGC Code(93)8.2.5
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 29 March 2021

Ownership record