CAJOLE is a 1978 towing vessel. The Coast Guard has recorded 37 inspections since 1995, most recently in May 2025, along with 14 deficiencies, 1 operational control and 8 casualty investigations between 2004 and 2024.
Records from 1995 to 2025. Most recent: inspection, 28 May 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)60.7 ft × 23.0 ft × 6.5 ft
Registered tonnagegross 96 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUPERIOR BOAT WORKS INC · GREENVILLE, MS, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton 47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 4 June 2024Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. Crew could not conduct drills due to air starter on stbd engine not operating. Marine inspector must witness drills prior to operation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2024
Resolved 11 June 2024
Resolution: MI witnessed MOB adn Firefighting drills. Crew was extremely proficient with drills. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 June 2024Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Air starter inoperable when starting starboard engine. Diagnose cause of inoperable air starter and plan for repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2024
Resolved 11 June 2024
Resolution: MI verified that the started was replaced. Verified full operation of plant. All sat.
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. RPM, oil pressure, jacket water alarms not communicating with pilot house if there were an emergency. Diagnose cause of inoperable alarms to pilot house and plan for repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2024
Resolved 11 June 2024
Resolution: Verified operation of RPM, MDE oil pressure, and jacketwater alarms on the bridge. verified visual and audible alarms. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 June 2024Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot tube pressure of at least 50 psi and a flow rate of at least 80 gallons per minute. The fire pump gauge is broken and fire main is leaking. Must have a way to verify psi and secure leak on fixed fire pump.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 11 June 2024
Resolution: MI verified that fire pump has a gauge verifying proper PSI. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2024Resolved
Machinery must be designed and maintained to provide safe operation of the towing vessel under normal and emergency conditions. Vessel reported a failure to the starboard main engine resulting in a loss of propulsion. Troubleshoot and diagnose cause of failure to the satisfaction of attending USCG Inspector prior to further towing operations.
Action required: 705 - Other - as specified
Due 27 January 2024
Resolved 6 February 2024
Resolution: Engine repaired. Intermittent shut down caused by bad fuel and a safety sensor. Fuel changed out and sensor replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 May 2023Resolved
Alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location.
Marine Observed high bilge level alarm not visible or audible at operating station on bridge. Repair alarm to satisfactory condition. 46CFR132.230(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 May 2023
Resolution: Received satisfactory video evidence of fully operational bilge alarm.
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Observed wasted and missing pieces of rubber seal on watertight door leading from main deck to galley. Replace damaged seal.46CFR140.610(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 31 May 2023
Resolution: Received photos of newly adjusted WT door and new gasket. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2021Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Openings access to wiring within the distribution panels were observed in the wheelhouse and storage room distribution panels, install covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 17 August 2021
Resolution: Received photographs of covering installed on both distribution panel openings.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 13 August 2021Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Excessive oily film was observed on the engine room blowers and surrounding area, clean and remove oily film.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 17 August 2021
Resolution: Received photographs of engine room blowers cleaned of oily residue.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 July 2021Resolved
If the Master or Officer in charge of a Navigational watch believes it is unsafe for the vessel to procede, that an operation endangers the vessel or crew, or that an unsafe condition exist, he or she must ensure that adequate corrective action is taken and must not proceed until it is safe to do so. 46 CFR 140.210(b)
Vessel allided with M/V MARTHA IVO Convent Marine terminal. Master of the vessel is required to provide USCG with statement attesting to: no damage occured to vessel or the barges, that a nav assessment was completed and that he feels the vessel is safe to transit for the intended voyage.
THe vessel is also required to provide the USCG with a copy of the Marine surveyor report, before or when vessel arrives at MM 120.
Action required: 60 - Rectify deficiencies prior to movement
Due 28 July 2021
Resolved 28 July 2021
Resolution: 28Jul21: Received statement from master. see attachment
Communications › Alarms/Indicators › General Alarm
Issued 29 September 2006Resolved
Vessel did not have red light in Engine room for general alarm
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 6 June 2012
29 June 2004Routine · role: Involved in a Marine Casualty · activity 2127109
7 September 2006Routine · role: Involved in a Marine Casualty · activity 2773723
2 September 2007Routine · role: Involved in a Marine Casualty · activity 3045889
22 October 2007Routine · role: Involved in a Marine Casualty · activity 3092001
21 July 2013Routine · role: Involved in a Marine Casualty · activity 4729080
25 June 2022Routine · role: Involved in a Marine Casualty · activity 7535967
21 January 2024Routine · role: Involved in a Marine Casualty · activity 7852706
12 June 2024Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7933737
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
TOBIE K DEVALL (2004–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.