Records from 1995 to 2025. Most recent: inspection, 28 May 2025.
Documentation record
Registered dimensions (L × B × D)60.7 ft × 23.0 ft × 6.5 ft
Registered tonnagegross 96 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUPERIOR BOAT WORKS INC · GREENVILLE, MS, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
28 May 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8146259
12 June 2024
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7933731
12 June 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7933737
28 May 2024
COI Inspection · MTSA Verification · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7907594
27 January 2024
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7856642
21 January 2024
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7852706
31 May 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7689786
18 July 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7499893
25 June 2022
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7535967
13 August 2021
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7272482
28 July 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7270192
26 April 2021
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7183264
15 April 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6939650
3 May 2019
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6675906
15 July 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6213083
21 July 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4729080
6 June 2012
DAPI Audit · Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4340657
22 October 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3092001
2 September 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3045889
2 November 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2813277
29 September 2006
Uninspected Other · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2789843
7 September 2006
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2773723
9 November 2005
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2646390
24 May 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2366795
19 April 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2337982
16 March 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2314054
30 January 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2283676
29 June 2004
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2127109
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979105
5 January 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 273397
19 August 1998
Uninspected Towing Vessel
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 802467
18 December 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 411111
18 June 1997
Uninspected Towing Vessel · MARPOL Annex V Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 781359
17 May 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 760725
14 May 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 196489
14 May 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 391246
1 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 447135
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 4 June 2024
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. Crew could not conduct drills due to air starter on stbd engine not operating. Marine inspector must witness drills prior to operation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2024
Resolved 11 June 2024
Resolution: MI witnessed MOB adn Firefighting drills. Crew was extremely proficient with drills. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 June 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Air starter inoperable when starting starboard engine. Diagnose cause of inoperable air starter and plan for repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2024
Resolved 11 June 2024
Resolution: MI verified that the started was replaced. Verified full operation of plant. All sat.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 4 June 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. RPM, oil pressure, jacket water alarms not communicating with pilot house if there were an emergency. Diagnose cause of inoperable alarms to pilot house and plan for repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2024
Resolved 11 June 2024
Resolution: Verified operation of RPM, MDE oil pressure, and jacketwater alarms on the bridge. verified visual and audible alarms. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 June 2024
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot tube pressure of at least 50 psi and a flow rate of at least 80 gallons per minute. The fire pump gauge is broken and fire main is leaking. Must have a way to verify psi and secure leak on fixed fire pump.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 11 June 2024
Resolution: MI verified that fire pump has a gauge verifying proper PSI. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2024
Resolved
Machinery must be designed and maintained to provide safe operation of the towing vessel under normal and emergency conditions. Vessel reported a failure to the starboard main engine resulting in a loss of propulsion. Troubleshoot and diagnose cause of failure to the satisfaction of attending USCG Inspector prior to further towing operations.
Action required: 705 - Other - as specified
Due 27 January 2024
Resolved 6 February 2024
Resolution: Engine repaired. Intermittent shut down caused by bad fuel and a safety sensor. Fuel changed out and sensor replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 May 2023
Resolved
Alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location.
Marine Observed high bilge level alarm not visible or audible at operating station on bridge. Repair alarm to satisfactory condition. 46CFR132.230(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 May 2023
Resolution: Received satisfactory video evidence of fully operational bilge alarm.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 31 May 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Observed wasted and missing pieces of rubber seal on watertight door leading from main deck to galley. Replace damaged seal.46CFR140.610(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 31 May 2023
Resolution: Received photos of newly adjusted WT door and new gasket. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Openings access to wiring within the distribution panels were observed in the wheelhouse and storage room distribution panels, install covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 17 August 2021
Resolution: Received photographs of covering installed on both distribution panel openings.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 13 August 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Excessive oily film was observed on the engine room blowers and surrounding area, clean and remove oily film.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 17 August 2021
Resolution: Received photographs of engine room blowers cleaned of oily residue.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 July 2021
Resolved
If the Master or Officer in charge of a Navigational watch believes it is unsafe for the vessel to procede, that an operation endangers the vessel or crew, or that an unsafe condition exist, he or she must ensure that adequate corrective action is taken and must not proceed until it is safe to do so. 46 CFR 140.210(b)
Vessel allided with M/V MARTHA IVO Convent Marine terminal. Master of the vessel is required to provide USCG with statement attesting to: no damage occured to vessel or the barges, that a nav assessment was completed and that he feels the vessel is safe to transit for the intended voyage.
THe vessel is also required to provide the USCG with a copy of the Marine surveyor report, before or when vessel arrives at MM 120.
Action required: 60 - Rectify deficiencies prior to movement
Due 28 July 2021
Resolved 28 July 2021
Resolution: 28Jul21: Received statement from master. see attachment
Communications › Alarms/Indicators › General Alarm
Issued 29 September 2006
Resolved
Vessel did not have red light in Engine room for general alarm
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 6 June 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 September 2006
Resolved
Required markings on life rings not present
Action required: 705 - Other - as specified
Resolved 29 September 2006
Resolution: corrected on the spot
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 29 September 2006
Resolved
Required lights not attached to life jackets/ on vessel
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 6 June 2012
Personnel › Certificates/Documents/Licenses › License, Master
Issued 29 September 2006
Resolved
Failure to have an uninspected towing vessel over 26 ft in length, under the control of a properly licensed individual.
Due 29 September 2006
Resolved 29 September 2006
Resolution: Removed induvidual from vessel and replaced with properly licensed induvidual