SEABOURN VENTURE
SEABOURN VENTURE is a 2022 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2022, most recently in September 2025, along with 9 deficiencies and 2 operational controls, 2 with no removal date recorded.
Records from 2022 to 2025. Most recent: inspection, 10 September 2025.
- Built
- 2022
- Last inspected
- 10 September 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- 2 with no removal date recorded
Identity
9862023 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6EL7
1653235
Flag
BAHAMAS, THE
—
Maury page id
psix-1653235
Inspections, by type
…with no type recorded2
Years with a record
4 calendar years (2022–2025)
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it23615 - Convention (Subpart B), Gross Ton
7155 - Convention (Subpart B), Net Ton
4200 - Dead Weight, Metric Ton
16572 - Displacement, Metric Ton
7155 - Convention (Subpart B), Net Ton
4200 - Dead Weight, Metric Ton
16572 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
10 September 2025
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8231160
27 August 2025
COC-CVE Annual · Polar Code Examination · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8213522
3 October 2024
COC-CVE Annual · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8011584
19 September 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7795284
17 September 2023
COC-CVE Annual · PSC A · Polar Code Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7790351
11 September 2023
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7790394
26 August 2023
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7796919
8 October 2022
Deficiency Check · COC-CVE Initial · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7563029
1 February 2022
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7388724
Deficiency record · 9
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 August 2025
Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. Identified pumps under the crew stairway on deck 3 main vertical zone 2 stored for emergencies. 07120- 74 SOLAS 20 II-2/13.1.2 16abc
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 October 2024
Resolved
Except for hatches between cargo, special category, store, an baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed that the vessels fire screen door (3.3.06) was incapable of closing all the way.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 October 2024
Resolved
Fire doors in the MVZ bulkheads, galley boundaries and stairway enclosures, except those for emergency escape trunks, shall be capable of remote release from the continuously manned central control station., either simultaneously or in groups, and shall be capable of release also individually from a position at both sides of the door. Release switches shall have an on-off function to prevent automatic resetting of the system. POSC observed galley roller fire door (5.2.05) would no close upon activation of local release mechanism.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 October 2024
Resolved
Spaces are classified according to their fire risk as shown in categories (1) to (14). The vessel's server room and electrical locker is a category (10) space where storage of combustibles is prohibited. PSCO observed that deck 4 storage room and deck 5 electrical locker was being used for storage of combustible materials.
74 SOLAS 20 II-2/9.2.2.3.2.2
10c
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 8 October 2022
Resolved
No manufacturer may manufacture for sale, sell, offer for sale, or distribute for sale or resale any vessel equipped with an installed toilet facilities unless it is equipped with an operable Type II or III device that has a label on it under 33CFR159.16 or that is certified under 33CFR159.12 or 33CFR159.12a. The black water system did not have an approval plate attached. This is item #49 on the ICOC worklist.
33CFR159.5(b)
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 8 October 2022
Resolved
Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the Fire Safety Systems Code. The vessel did not have an international shore connection onboard. This is item #44 on the ICOC Worklist.
74SOLAS(20) II-2/10.2.1.7.1
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 8 October 2022
Resolved
The frequency of the tests and inspections required by this section must be; for vessels, annually or as part of the biennial and mid-period inspections. Transfer hoses used for vessel tenders have not been hydrostatically tested. This is item #42 on the ICOC worklist.
33CFR156.170(f)(3)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 October 2022
Resolved
Fire-extinguishing arrangments in machinery spaces of category A, in addition to the fixed fire-extinguishing system, must be protected by an approved type of fixed water-based or equivalent local application fire-fighting system, based on the guidelines developed by the Organization. In the case of periodically unattended machiner spaces, the fire-fighting system shall have both automatic and manual release capabilities. The vessel was not constructed with a means of activating the local fixed fire-extinguishing system in Deck 2 for the FWD and AFT boiler. This is item #36 on the ICOC worklist.
74SOLAS(20)II-2/10.5.6.2
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 October 2022
Resolved
Drills shall, as far as practicable, be conducted as if there were an actual emergency. During the abandon ship drill, the vessel deployed a 16 passenger training life raft when the vessel carries 35 passenger life rafts. The vessel is required to use and train with the same size life raft as is carried.
74SOLAS(20)III/19.3.1