BBC ICELAND is a 2013 public freight. The Coast Guard has recorded 9 inspections since 2022, most recently in September 2025, along with 8 deficiencies and 1 operational control.
Records from 2022 to 2025. Most recent: inspection, 20 September 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it18567 - Convention (Subpart B), Gross Ton 24935 - Dead Weight, Metric Ton 33568 - Displacement, Metric Ton 8204 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
20 September 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8237926
31 May 2024PSC B · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7921357
30 May 2024Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7922913
30 May 2024Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7923089
27 May 2024COE-Administrative
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7922891
23 October 2023PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7809345
12 October 2023Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7807268
17 December 2022Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7610398
28 November 2022PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7600515
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 October 2023Resolved
Firefighting systems and appliances shall be kept in good order and readily available for immediate use. PSCO observed that the CO2 cyclinders valve safety pins were not removed per manufacture instruction. The safety pins should be taken out after delivery from shipyard.
74 SOLAS II-2/14.2.1.2
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2023
Resolved 12 October 2023
Resolution: Received Class(BV) report stating thatsafety pins were removed from the automatic release bottles.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 October 2023Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed leaks on MDG's purifers, oil accummulation around #1, #2, and #3 MDE Cyclinder heads. Additionally, fuel samples containers in the steering gear room. The fuel samples were also leaking and fuel oil accumulation was observed around the samples and on the steering gear room deck.
74 SOLAS (20) II-2/4.1.1
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2023
Resolved 12 October 2023
Resolution: Received Class(BV) report stating that the purifier gasket replaced and no further leakage. noted
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 October 2023Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed several 55 gallon lube oil drums and 5 gallon buckets stored in the stearing gear room blocking access to the firefighting equipment.
74 SOLAS II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2023
Resolved 12 October 2023
Resolution: Received Class(BV) report stating that FO Samples relocated to paint locker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 October 2023Resolved
Provision shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery including boilers and pressure vessels. PSCO observed #2 boiler welder pump actively leaking and #1 boiler pump with corrosion and evidence of leaks.
74 SOLAS (20) II-I/26.7
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2023
Resolved 12 October 2023
Resolution: Received Class(BV) report stating that No2 boiler pump o ring replaced, no1 boiler pump shaft seal was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 October 2023Resolved
The machinery, boiler and other pressure vessels associated piping shall be of a design and construction adequate for the service they are intended and so installed and protected to reduce any dangers to persons onboard, due regard being paid to moving parts. PSCO observed missing covers on all service pumps, ballast pumps and fire pumps.
74 SOLAS (20) II-I/26.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2023
Resolved 31 May 2024
Resolution: PSCO VERIFIED RECTIFICATION TO CLOSE OPEN DEF
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 October 2023Resolved
Each survival craft shall be stowed in a state of continuous readiness so that 2 crew members shall carry out preparations for embarkation and launching in less than 5 minutes. PSCO observed 02 crew members failed to comply with the 5 minute time requirement.
74 SOLAS (20) III/13.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 28 November 2022Resolved
A general emergency alarm system shall be aubible throughout all the accommodation and normal crew working spaces. PSCOs observed an inoperable general alarm system while conducting drills.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2022
Resolved 30 November 2022
Resolution: Vessel surveyor determined the cause to be a defective relay switch. Vessel replaced the switch and issued a statement proclaiming audible alarm functions properly.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 November 2022Resolved
The Master, owner, operator, agent, or PIC of any vessel equipped with ballast water tanks that operates in the waters of the United States must maintain a BWM plan. The Plan must include actions for implementing mandatory BWM requirements and practices. Currently, vessel does not have an installed and approved BW treatment system nor does the onboard ballast management plan address not conducting ballast water exchanges within U.S. waters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2022
Resolved 30 November 2022
Resolution: Vessel recieved an extension for the implimentation of an approved Ballast Water Treatment System.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National