Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it115338 - Convention (Subpart B), Gross Ton 88907 - Dead Weight, Ton 124590 - Displacement, Ton 34602 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
2 May 2025COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8118454
29 March 2024COC-GAS Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7884109
17 August 2022COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7534241
17 November 2021PSC A · Deficiency Check · COC-GAS Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7352632
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 17 November 2021Resolved
08199- A continuous reading oxygen content meter shall be fitted to the inert gas supply from the equipment and shall be fitted with an alarm set at a maximum of 5% oxygen content by volume. The crew was unable to demonstrate proper operation of the oxygen content alarm.
74SOLAS(20)VII/13/1
IGC Code (2016)9.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 November 2021
Resolution: PSCO witnessed successful operation of the oxygen content alarm while onboard.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 17 November 2021Resolved
15109- Detailed instructions shall be provided on board, covering the operations, safety and maintenance requirements, and occupational health hazards relevant to the inert gas system. The vessel was unable to provide procedures for the testing of the oxygen content alarm for the nitrogen generator.
74SOLAS(20)II-2/4.5.5.3.2
FSS Code 15.2.2.5
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2021
Resolution: Recieved documentation of procedures in place for testing the O2 alarm on the nitrogen generator.