Records from 1990 to 2011. Most recent: inspection, 9 September 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
9 September 2011
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4140043
15 April 2008
Ballast Water Examination · Hull Examination · Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3184356
15 March 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2888763
10 October 2006
Ballast Water Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2797153
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539937
15 April 2005
Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2339519
23 November 2004
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2246825
16 November 2004
Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2241791
15 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2242821
25 March 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2030939
8 April 2003
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1771376
30 May 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626638
10 July 2001
Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401508
1 March 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381814
27 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 796468
3 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774479
26 April 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453604
24 February 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433303
6 May 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383541
27 December 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 764440
23 November 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 202060
1 March 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469456
16 February 1995
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357019
14 July 1994
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 669638
24 May 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854207
21 May 1994
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 66102
4 March 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379923
3 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151706
3 June 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669631
20 April 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422226
13 August 1992
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356146
19 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1009562
25 April 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240833
2 April 1991
Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1234407
31 January 1990
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927444
Engineering › Compressed Air System (control) › Compressor
Issued 9 September 2011
Resolved
Information on air compressor data plate not legible. Remove paint on air compressor data plate.
Action required: 705 - Other - as specified
Resolved 13 September 2011
Lifesaving › Lifefloat › Markings
Issued 9 September 2011
Resolved
Re-stencil name on lifefloat where faded.
Action required: 705 - Other - as specified
Resolved 13 September 2011
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 September 2011
Resolved
Engine room emergency light inop. Replace light and demonstrate proper operation.
Action required: 705 - Other - as specified
Resolved 13 September 2011
Fire Fighting › Fire Pumps › Pressure
Issued 9 September 2011
Resolved
Demonstrate proper pressure of fire pump.
Action required: 705 - Other - as specified
Resolved 13 September 2011
Electrical › Electric Generation Source (service) › Generator
Issued 9 September 2011
Resolved
Demonstrate overspeeds of generator primemover.
Action required: 705 - Other - as specified
Resolved 13 September 2011
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 10 October 2006
Resolved
Per NAVIC-8-91 vessel hydraulic systems must substantially meet the requirements of 46CFR 58.30 and 56.30. Provide third party inspection of all system components, to identify systems with or without counter balance valves, and any components not rated for maximum system operating pressure. Repair/replace all identified components.
Action required: 705 - Other - as specified
Due 10 October 2007
Resolved 14 August 2007
Construction/Loadline › Hull › Weld
Issued 16 November 2004
No resolution recorded
Prior to cargo operations or carriage of persons in addition to the crew, vessel is to proceed directly to Bollinger Amilia, LA for repairs. All repairs to be completed to the satisfaction of the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 December 2004 — due date passed with no resolution recorded
Resolution: Repairs complete.
Fire Fighting › Fire Pumps
Issued 30 May 2002
Resolved
Port submersible fire pump inop. LEGACY COMPONENT DESC: Power Source
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2002
Resolution: Renewed pump.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 30 May 2002
No resolution recorded
Jacking system hydraulic level alarm inop.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Repaired.
Construction/Loadline › Structures › Machinery Space Opening
Issued 30 May 2002
Resolved
Newly installed e/r escape scuttles need adjusting.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2002
Resolution: Adjusted.
Lifesaving
Issued 26 April 1999
Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's policy "Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Documentation
Issued 20 April 1993
Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER OR IF ISSUED BY ABS,SUBMIT ABS ISSUED STABILITY LETTER TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Documentation
Issued 20 April 1993
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Documentation
Issued 20 April 1993
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORT TO [name withheld].
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Engineering
Issued 2 April 1991
Resolved
PROVIDE AND PROVE OPERATION OF OVERSPEED TRIPS ON BOTH MAIN ENGINES AS PER 46 CFR 176. 25-1(C).
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Documentation
Issued 31 January 1990
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Lifesaving
Issued 31 January 1990
Resolved
SUBMIT FOR APPROVAL A SUITABLE MEANS OF ESCAPE TO [name withheld].
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Fire Fighting
Issued 31 January 1990
Resolved
INSTALL OR REPAIR FIRE PUMP TO PROVIDE SUFFICIENT PRESSURE FOR TWO (2) EFFECTIVE STREAMS TO ALL PARTS OF THE VESSEL.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Documentation
Issued 31 January 1990
Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER OF IF ISSUED BY ABS, SUBMIT ABS ISSUED STABILITY LETTER TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Deck/Cargo
Issued 31 January 1990
Resolved
PROPERLY INSTALL BOOM ANGLE INDICATOR ON CRANE.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Engineering
Issued 31 January 1990
Resolved
PROVIDE VISUAL INDICATOR ON BILGE ALARM SYSTEM FOR EACH MACHINERY SPACE.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Unknown
Issued 31 January 1990
Resolved
PROVIDE VISUAL INDICATOR FOR LOW HYDRAULIC LEVEL ALARM FOR JACKING SYSTEM.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Documentation
Issued 31 January 1990
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Documentation
Issued 31 January 1990
Resolved
PLACE A U.S. COAST GUARD CERTIFICATE OF DOCUMENTATION ON BOARD AND MAIL A COPY TO [name withheld].
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990