Records from 1990 to 2016. Most recent: inspection, 27 June 2016.
Inspection history · 35
27 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5921342
12 August 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5214146
2 June 2014
Annual Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4879203
9 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4241232
5 January 2012
Hull Examination · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4219322
7 December 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3645775
1 April 2008
Annual Inspection · Examination of Repairs · Damage Survey · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3179834
9 August 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2741466
8 August 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2739719
16 March 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2598079
16 December 2004
Ballast Water Examination · Re-Inspection · MTSA Verification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2268526
17 December 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1965679
12 December 2002
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1717094
2 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1599804
13 February 2002
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1486082
10 December 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410711
9 December 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395308
5 May 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1127222
12 April 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 787937
12 March 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384070
30 June 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1127350
27 June 1998
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 793247
26 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 5395
20 January 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372155
21 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460934
15 February 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359062
22 February 1995
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385374
23 February 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356524
1 June 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1148949
23 March 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407130
30 January 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1257491
13 June 1991
Re-Inspection · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231933
30 October 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212312
1 June 1990
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233884
16 May 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 908060
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 June 2014
Resolved
A/C electrical box on 3rd deck was waisted and needs to be replaced
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2014
Resolved
Ensure all wiring in engine room is supported every 24"
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2014
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 2 June 2014
Resolved
Metal bowls under fuel strainers have plastic plugs. Plugs need to be replaced with metal plugs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2014
Engineering › Lubricating Oil Service System › Gauge
Issued 5 January 2012
Resolved
Lub oil pressure guage was non-operational at the operating station
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2012
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 January 2012
Resolved
Clip on securing strap buckle is manufactured to long and the clip will not secure to the O ring. Manufacturer's defect is the cause of the issue.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2012
Fire Fighting › Fire Pumps › Pressure
Issued 16 December 2004
Resolved
Provide 50psi fire pump as required.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2005
Resolved 20 December 2004
Resolution: Provided
Documentation › Manuals/Policy Documentation
Issued 17 December 2003
Resolved
Provide approved operations amanual.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2004
Resolved 17 December 2004
Electrical › Electrical Distribution System (service)
Issued 17 December 2003
Resolved
Provide new stbd main engine lube oil gage at pilothouse operating station. LEGACY COMPONENT DESC: gage
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2004
Resolved 17 December 2004
Lifesaving › Lifebuoys
Issued 17 December 2003
Resolved
Renew all retro tape on all liferings and lifefloats. LEGACY COMPONENT DESC: Retro tape
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2004
Resolved 17 December 2004
Lifesaving › Buoyant Apparatus
Issued 17 December 2003
Resolved
Provide proper weaklinks for both lifefloats. LEGACY COMPONENT DESC: Lifefloats
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2004
Resolved 17 December 2004
Engineering › Fuel Oil Service System › Hose
Issued 17 December 2003
Resolved
Renew 3 fuel oil hoses on hydraulic engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2004
Resolved 17 December 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 December 2003
Resolved
Renew hose on co2 fire extinguisher on port side engineroom.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2004
Resolved 17 December 2004
Stability › Watertight Integrity
Issued 17 December 2003
Resolved
Adjust dogs on watertight door leading into laundry room. LEGACY COMPONENT DESC: Watertight door
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2004
Resolved 17 December 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 17 December 2003
Resolved
Rearrange electrical disconnect for deep fat fryer. LEGACY COMPONENT DESC: Deep fat fryer
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2004
Resolved 17 December 2004
Navigation › Collision/Grounding Avoidance
Issued 12 December 2002
Resolved
Install restricted in ability to manuver lights IAW nav rule 27 of 1972 colregs. LEGACY COMPONENT DESC: Navigation Lights
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 February 2003
Resolved 7 January 2003
Resolution: Installed.
Accommodation/Occupational Safety
Issued 10 December 2001
Resolved
INSTALL SEA RAILS ON THE GALLEY STOVE.
Condition: Unknown
Due 10 January 2002
Resolved 13 February 2002
Electrical
Issued 10 December 2001
Resolved
REPLACE A/C BREAKER BOX ON WEATHER DECK.
Condition: Unknown
Due 10 January 2002
Resolved 13 February 2002
Navigation
Issued 10 December 2001
Resolved
INSALL RUDDER ANGLE INDICATOR SYSTEM AS PER 46 CFR 113.40 (1976 EDITION)_x001C_ TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 10 February 2002
Resolved 13 February 2002
Engineering › Shafting/Propeller Arrangements
Issued 10 December 2001
Resolved
Port propeller missing LEGACY COMPONENT DESC: Propeller (fixed pitch)
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2001
Resolved 10 December 2001
Resolution: propeller installed
Engineering › Shafting/Propeller Arrangements
Issued 10 December 2001
Resolved
port shaft not installed. LEGACY COMPONENT DESC: Propeller Shaft
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2001
Resolved 10 December 2001
Resolution: port shaft installed
Engineering › Steering Gear System
Issued 10 December 2001
Resolved
port rudder removed LEGACY COMPONENT DESC: Rudder
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2001
Resolved 10 December 2001
Resolution: rudder installed
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 December 2001
Resolved
Starboard MDE shut down switch did not function.
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: replaced defective switch
Communications › Radio Communications
Issued 10 December 2001
Resolved
SSB inop LEGACY COMPONENT DESC: Radiotelephone Transveiver (2-4 MHz)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2001
Resolved 10 December 2001
Engineering › Compressed Air System (start air) › Piping
Issued 10 December 2001
Resolved
MDE start air piping required additional bracing.
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: installed additional bracing.
Engineering › Fuel Oil Service System › Piping
Issued 10 December 2001
Resolved
PMDE fuel supply line leaking.
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: Replaced defective piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 December 2001
Resolved
PMDE missing exhaust lagging.
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: installed missing lagging.
Lifesaving › Buoyant Apparatus
Issued 10 December 2001
Resolved
lifefloat pendants not secured.
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: secured pendants
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 10 December 2001
Resolved
Fuel tank vent screens were clogged
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: replaced vent screens.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 December 2001
Resolved
electrical wiring in port and starboard engine rooms not properly secured
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: installed cable retainers.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 December 2001
Resolved
microwave oven and milk machine not secured. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2001
Resolved 10 December 2001
Accommodation/Occupational Safety › Occupational Safety
Issued 10 December 2001
Resolved
starboard E/R emergency exit hatch safety chain not attached to the vessel.
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: attached safety chain.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 December 2001
Resolved
Light in 0-3 deck head not secured.
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: secured light
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 December 2001
Resolved
lifering water light inoperable.
Condition: Improper/Lack of Maintenance
Due 10 December 2001
Resolved 10 December 2001
Resolution: replaced light
Lifesaving › Hand Flares
Issued 10 December 2001
Resolved
missing 3 visual distress signals.
Condition: Unknown
Due 10 December 2001
Resolved 10 December 2001
Resolution: replaced missing signals.
Documentation › Certificates/Documents
Issued 10 December 2001
Resolved
official document missing the current renewal sticker. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 10 December 2001
Resolved 13 February 2002
Lifesaving
Issued 12 March 1999
Resolved
ATTACH WATER LIGHTS TO NEW PFD'S.
Condition: Unknown
Due 12 April 1999
Resolved 15 March 1999
Construction/Loadline
Issued 12 March 1999
Resolved
PROPERLY INSTALL BILGE HIGH LEVEL ALARMS IAW 46 CFR 182.530.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Deck/Cargo
Issued 12 March 1999
Resolved
PROPERLY SECURE SOAP TANK TO VESSEL.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Fire Fighting
Issued 12 March 1999
Resolved
REPLACE THE TWO FORWARD HOSES ON THE PORT SIDE PTO.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Lifesaving
Issued 12 March 1999
Resolved
PROVIDE REGISTRATION FOR EPIRB.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Accommodation/Occupational Safety
Issued 12 March 1999
Resolved
INSTALL METALLIC DRYER EXHAUST HOSE.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Navigation
Issued 12 March 1999
Resolved
PROPERLY SECURE PACKING GLANDS ON RUDDER STOCKS.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Electrical
Issued 12 March 1999
Resolved
INSTALL ELECTRICAL MATTING IN FRONT OF SWITCH BOARDS.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Accommodation/Occupational Safety
Issued 12 March 1999
Resolved
PROPERLY SECURE LOCKERS IN ACCOMMODATION SPACES.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Lifesaving
Issued 12 March 1999
Resolved
PROPERLY REPLACE NETTING IN BUOYANT APPARATUS STBD SIDE.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Accommodation/Occupational Safety
Issued 12 March 1999
Resolved
REPLACE RELIEF VALVE ON WATER HEATER WITH 100 PSI RELIEF VALVE OF LESS.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Engineering
Issued 12 March 1999
Resolved
PROPERLY REPAIR PACKING GLAND ON STBD MDE.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Engineering
Issued 12 March 1999
Resolved
REMOVE ALL PETCOCKS FROM RAYCOR FUEL FILTER BOWLS AND INSTALL STAINLESS STEEL OR BRASS PLUGS.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Construction/Loadline
Issued 27 June 1998
Resolved
MAKE PROPER AND PERMANENT REPAIRS IN WAY ON DAMAGE OF THE PORTSIDE AFT CORNER (18"X18"X40). VESSEL IS NOT PERMITTED BACK INTO SERVICE UNTIL REPAIRS ARE INSPECTED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 27 June 1998
Resolved 27 June 1998
Documentation
Issued 1 June 1990
Resolved
PROVIDE ONBOARD A ROUGH COPY OF A OPERATIONS MANUAL MEETING THE APPLICABLE SECTION OF 46 CFR 109.121.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990
Resolved
PROVIDE ONBOARD A FIRE CONTROL PLAN.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGENMENT, INBOARD AND OUTBOARD PROFILE, AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWERS SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE COAST GUARD MARINE SAFETY CENTER FOR ISSUANCE OF A STABILITY LETTER.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990