MAURY USCG vessel records
← All vessels

KORI BELL

KORI BELL is a 1978 offshore supply vessel. The Coast Guard has recorded 11 inspections since 2016, most recently in July 2026, along with 39 deficiencies and 1 casualty investigation in 2005.

Records from 2005 to 2026. Most recent: inspection, 15 July 2026.

Built
1978
Last inspected
15 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDE6851
165517
Flag
UNITED STATES
Maury page id
psix-165517

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)63.2 ft × 24.1 ft × 4.8 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUPERIOR LIFT BOATS INC · LAFAYETTE, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBAYTOWN, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 July 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 11

15 July 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8438958
3 April 2025 Drydock Exam · Internal Structural Exam · Annual Inspection · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8104780
16 July 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7959591
16 September 2021 Deficiency Check · COI Inspection · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7313430
29 September 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7067992
29 October 2019 Examination of Repairs · COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6844854
26 April 2019 Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6672664
12 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6538829
7 June 2017 Annual Inspection · MTSA Verification · DAPI Audit · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6168704
3 June 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5896628
7 January 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5921655

Deficiency record · 39

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2025 Resolved
The fixed power bilge pump shall be self-priming and may be driven off the main engine or other source of power. It shall be permanently connected to the bilge main and may also be connected to the fire main. If of sufficient capacity the power bilge pump may also serve as a fire pump. Bilge pump unable to self-prime. Affect satisfactory repairs/replacement of bilge pump to produce self-priming capabilities. No vessel movement until witnessed by USCG Inspectors and satisfactory underway drills are conducted.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2025
Resolution: Self-priming pump replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 June 2025 Resolved
All hand portable fire extinguishers and semi-portable fire extinguishing systems shall be checked as noted in Table 176.25-25(a). MIs observed expired portable extinguisher inspection in accommodation space near galley. Conduct required inspection of portable fire extinguisher. 46 CFR 176.25-25 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 7 July 2025
Resolution: Updated inspection completed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 June 2025 Resolved
The minimum number of portable fire extinguishers required on each vessel shall be as determined by the Officer in Charge, Marine Inspection, in accordance with Table 181.30-1(a) and other provisions of this subpart. MIs observed missing fire extinguisher in accommodation space. Provide appropriate fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 7 July 2025
Resolution: Missing fire extinguisher replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 26 June 2025 Resolved
A vessel must comply with the applicable requirements for any radio...installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission. MIs observed FCC Radiotelephony Certificate displaying previous vessel name of "Oppertunity". Update documentation to reflect current name of vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Radiotelephony certificate received.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2024 Resolved
A suitable rescue boat shall be required except when, in the opinion of the Officer in Charge, Marine Inspection, the vessel is of such design and operating characteristics that the vessel itself provides a fully satisfactory rescue platform. Rescue boat engine was not installed on boat. 46 CFR 180.10-35
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
Resolution: New outboard engine installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2024 Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and a float-free link. Life float was connected to stbd rail with zip ties. 46 CFR 180.20-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
Resolution: New lif float properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2024 Resolved
Each life float shall be fitted with a life line and shall be equipped with two paddles, a water light and a painter. Life float was missing all required equipment. 46 CFR 180.15-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
Resolution: Life float outfitted with required equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2024 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel is short 01 lifejacket. 46 CFR 180.25-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
Resolution: New lifjacket on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2024 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Vessels main bilge pump is inoperable. 46 CFR 182.25-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2024
Resolution: Installed bilge system operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 July 2024 Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered. Emergency exit in crew berthing was seized shut. 46 CFR 177.15-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2024
Resolution: Emergency exit repaired and in good working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline. Vessels bilge alarms were inoperable. 46 CFR 182.530(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
Resolution: Bilge alarms working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2024 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Hydraulic lifting system was low on oil/ Level Alarm on bridge is inoperable. Repair replace to satisfaction of CG Marine Inspector. 46 CFR 182.10-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
Resolution: Hydrolic tank topped off and Level alarm working properly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 July 2024 Resolved
A vessel at anchor shall exhibit where it can best be seen:(i) In the fore part, an all-round white light or one ball;(ii) At or near the stern and at a lower level than the light prescribed in paragraph (i) of this Rule, an all-round white light. All-round white light was inoperable. Repair prior to anchoring between sunset and sunrise. 33 CFR 83.30(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
Resolution: Light working properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 July 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Dead end wires forward of pilot house. 46 CFR 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 July 2024
Resolution: Dead end wires removed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 July 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Missing guard on port side shaft. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2024
Resolution: Safety guard installed on port shaft.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 July 2024 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. In addition. Multiple lights in machinery space were inoperable. 46 CFR 183.10-20
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2024
Resolution: All lights in machinery space working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 September 2021 Resolved
Service use of distress signals shall be limited to a period of 3 years. Distress signals were expired.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Provided new flares
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 September 2021 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up to date charts, sailing directions, coast pilots, light lists, and tide tables. There were no current charts or pubs onboard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Provided new charts
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2021 Resolved
Battery terminals shall be of the soldered type. Spring clips or other temporary type clamps are not permitted. Alligator clips were connected from a battery charger to the marine batteries.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Removed battery charger
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 September 2021 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Bunk room #2 watertight hatch is unable to be sealed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Adjusted hatch
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 September 2021 Resolved
Each hatch exposed to the weather must be watertight. The hatch above the port MDE is unable to be sealed properly.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Adjusted hatch
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2021 Resolved
All electrical installations shall be to the satisfaction of the OCMI. The dual generator interlock on the switchboard is inoperable and doesn't prevent inadvertent parallel of generators.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Replaced breaker with a longer switch
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 16 September 2021 Resolved
The power fire pump shall be selfpriming and of such size as to discharge an effective stream. The submersible fire pump provided while jacked up is inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Provided new sub pump
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 September 2021 Resolved
Nothing in this part shall be construed as limiting the Marine Inspector from making such tests or inspection as are reasonable and practicable to be assured of the seaworthiness of the vessel. The vessel leveling alarm did not sound when vessel was out of level.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Corrected the level alarm timing
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 September 2021 Resolved
When fire extinguishing systems or equipment are installed but not required, the installation shall meet the requirements of 46CFR181. Smoke detectors in the galley and first bunk room were not operational
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2021
Resolution: Replaced batteries in detectors
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 September 2021 Resolved
Bolt down and secure fresh water pump
Due 31 January 2023
Resolved 7 February 2023
Resolution: Pump secured.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 September 2021 Resolved
Shutoff valves installed so as to close against the fuel flow,shall be fitted in the fuel supply lines. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Marine inspector observed no remote fuel shutoff for fuel tank. Install remote fuel shutoff for fuel tank. 46 CFR 182.20-40(b)(3) 17 C
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2023
Resolved 7 February 2023
Resolution: Remote fuel shutoff valve installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 September 2021 Resolved
During an initial inspection for certification the owner or managing operator shall conduct all tests and make the vessel available for all applicable inspections discussed in this paragraph, and in Subpart H of this part, to the satisfaction of the cognizant OCMI, including the following: Tests of each rescue boat and each rescue boat launching appliance. Marine inspector observed rescue boat inoperable. Repair rescue boat to full operational condition to the satisfaction of a US Coast Guard Marine Inspector. 46 CFR 176.808 17 C
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2023
Resolved 7 February 2023
Resolution: Rescue boat repaired.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 September 2021 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments under all practical conditions. Marine Inspector discovered missing control handles on emergency bilge suction lines located in engine room. Repair/replace control handles on emergency bilge suction lines. 46 CFR 182.25-1 17 C
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2023
Resolved 7 February 2023
Resolution: New handles installed on bilge suction lines.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2020 Resolved
If a grounded distribution system is provided, there must be only one connection to ground regardless of the number of power sources. Determine type of distribution system and properly ground and provide required ground detection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 29 September 2020
Resolution: Ground detection added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2020 Resolved
ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. Vessel did not have Ammeters for measuring amperage for either generator on the switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 30 September 2020
Resolution: Ammeter installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2020 Resolved
Each switchboard must be fitted with a drip shield. - Vessel switchboard not equipped with drip shield.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 29 September 2020
Resolution: Drip shield fitted.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 June 2020 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. - Compass light inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 29 September 2020
Resolution: Compass light works.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020 Resolved
Vessel's hand rail system only had 02 rails that were more than 12 inches apart. Correct deficiency at next dry dock.
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 7 July 2025
Resolution: Cleared with satisfactory DD inspection.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 June 2020 Resolved
Vessel is a OSV Lift boat restricted in maneuverability. Provide a means to recover personnel from the water while in the raised configuration, as well as when in the lowered configuration. Current rescue boat cannot be raised with persons onboard due to crane and winch not being rated for personnel. Develop alternate means of recovering persons overboard or certify winch is rated for use to hoist personnel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 29 September 2020
Resolution: Crane was certified by International Cargo Gear Bureau
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 September 2018 Resolved
Materials and/or personnel handling equipment systems, i.e. cranes, hydraulic elevators, etc., not approved by the Commandant as fail-safe as defined in paragraph (a)(2) of this section. Vessel controls for the leg operations was not a fail-safe design.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2018
Resolution: Tested leg operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2018 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q. Starboard life buoy plug was dry rotted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2018
Resolution: Replaced in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 12 September 2018 Resolved
An existing vessel must comply with the subdivision, damage stability, and watertight integrity regulations which were applicable to the on March 10, 1996, or, as an alternative, the vessel may comply with the regulations in this part. Starboard watertight door frame for the crew accommodations was severely deteriorated. Also, a deck plug on the port side near the house was wasted away.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2018
Resolution: Cropped and renewed.
Deck/Cargo › Cargo Stowage › General
Issued 3 June 2016 Resolved
The forward leg didn't operate. Demonstrate proper operation of the forward lift leg.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 16 August 2016
Resolution: Cleared by technician's report.

Casualty record · 1

12 December 2005Routine · role: Involved in a Marine Casualty · activity 2551519
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

THE OPPORTUNITY (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.