Records in 2021. Most recent: inspection, 28 April 2021.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2021
Resolved
07106 - FIRE ALARM AND FIRE ALARM SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. MULTIPLE SMOKE DETECTORS WERE FOUND INOPERABLE INCLUDING 2 IN THE ENGINE CONTROL ROOM, 1 IN THE PURIFIER ROOM, 1 IN THE FORWARD MAIN ENGINE LOWER DECK.
74SOLAS(14)II-2/14.2.1.1.2
17AC
Action required: 60 - Rectify deficiencies prior to movement
Due 28 April 2021
Resolved 28 April 2021
Resolution: Received satisfactory class report attesting to proper operation of all noted smoke detectors.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 28 April 2021
Resolved
15106 - THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELAVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPAMY. PSCO'S OBSERVED SMOKE DETECTORS BEING TESTED WITH A CIGARETTE. THE ELECTRICIAN STATED HE GENERALLY USES CIGARETTE SMOKE TO TEST THE SMOKE DETECTORS BECAUSE IT WORKS BETTER THAN THE CANNED SMOKE. IN ACCORDANCE WITH THE FIRE DETECTION SYSTEM INSTALLATION MANUAL, "SMOKE DETECTOR TESTER" IS THE RECOMMENDED TEST EQUIPMENT FOR SMOKE DETECTORS.
74SOLAS(14)IX/3.1; ISM CODE 10.1
17AC
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2021
Resolved 28 April 2021
Resolution: Received satisfactory class report attesting to proper test procedures being followed of smoke detectors via canned smoke detector test medium prescribed by system manual.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 28 April 2021
No resolution recorded
09211 - PIPING SYSTEMS SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ONBOARD WITH DUE REGARD TO HOT SURFACES. PSCOs OBSERVED STEAM PIPELINES ON DECK WITH DETERIORATED AND MISSING LAGGING. ADDITIONALLY, THE STEAM PIPELINE HAD MULTIPLE AREAS OF PATCHES WITH TAPE AROUND THE PIPELINE. 74SOLAS(14)II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 28 April 2021
Resolved
09229 - THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. PSCO OBSERVED HYDRAULIC LEAK AT ANCHOR WINCH PUMPS, OIL POOLED WITHIN THE CONTAINMENT, AND OIL SOAKED RAGS. 74SOLAS(14)1/11(A)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 28 April 2021
Resolution: Received satisfactory class report attesting to removal of hydraulic oil accumulation and no present leaks in anchor windlass hydraulic system by ABS surveyor.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 28 April 2021
Resolved
01315 - EACH OPERATION SHALL SHALL BE FULLY RECORDED WITHOUT DELAY IN THE OIL RECORD BOOK (ORB) APPROPRIATE TO THE OPERATION COMPLETED AND EACH PAGE SHALL BE SIGNED BY THE MASTER OF THE SHIP. ON 17-27APR20 WERE NOT SIGNED BY THE MASTER SHIP. MARPOL 1/17.4
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
Resolution: CORRECTED ON THE SPOT