VIKING VENUS

VIKING VENUS is a 2021 passenger vessel (inspected). The Coast Guard has recorded 5 inspections since 2021, most recently in May 2026, along with 15 deficiencies.

Records from 2021 to 2026. Most recent: inspection, 17 May 2026.

Built
2021
Last inspected
17 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9833175
1655617
Flag
NORWAY
Maury page id
psix-1655617

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 3 calendar years (2021–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it47842 - Convention (Subpart B), Gross Ton
3640 - Dead Weight, Ton
25774 - Displacement, Ton
18858 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

17 May 2026 PSC A · Polar Code Examination · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8373247
13 May 2025 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8133361
7 May 2025 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8130542
29 April 2025 PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8120109
17 March 2021 COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 7157759

Deficiency record · 15

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 May 2026 Resolved
The stored energy shall be maintained at all times, as follows: compressed air starting systems may be maintained by the main or auxiliary compressed air receivers through a suitable non-return valve or by an emergency air compressor which, if electrically driven, is supplied from the emergency switchboard. While testing the secondary means of starting the emergency generator via air start, PSCO observed failure of the starting system resulting in overheating and damage to associated electrical wiring, rendering the emergency generator inoperable.74 SOLAS 20 II-1/44.3.2
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2026
Resolution: Repaired on the spot and retested. Found to be satisfactory after retest.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 May 2026 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. Fire doors A.2.13, 1.2.11 and 3.4.08 were observed not latching when released. Cite: 74 SOLAS 20 11-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2026
Resolution: Repaired on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 May 2026 Resolved
The Load Line ring, lines and letters shall be painted white or yellow on a dark background or in black on a light background. They shall also be permanently marked. PSCO observed the deck line was not painted black. ICLL 8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2026
Resolution: Painted on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2026 Resolved
Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler of an approved type complying with the requirements of the Fire Safety Systems Code in all control stations, accommodation and service spaces, including corridors and stairways. A gauge indicating the pressure in the system shall be provided at each section stop valve and at a central station. PSCO observed gauge on section valve A-47 inoperable, as well as multiple inoperable gauges on deck 7 zone 2 outside of World Café. Cite: 74 SOLAS 20 11-2/10.6.1.1, FSS 8.2.4.2.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2026
Resolved 14 June 2026
Resolution: Vessel replaced all gauges for all section valves.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 May 2026 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. PSCO observed fire door 3.2.09 closed in 04 seconds. Cite: 74 SOLAS 20 II-2/9.4.1.1.5.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2026
Resolution: Repaired on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 May 2026 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed 02 sprinkler ampules in the emergency generator room to be of a non-standard type. 74 SOLAS 20 11-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2026
Resolution: Repaired on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 May 2026 Resolved
Furniture in stairway enclosures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, be of restricted fire risk determined in accordance with the Fire Test Procedures Code, and shall not restrict the passenger escape route. The Administration may permit additional seating in the main reception area within a stairway enclosure if it is fixed, non-combustible and does not restrict the passenger escape route. Furniture shall not be permitted in passenger and crew corridors forming escape routes in cabin areas. In addition to the above, lockers of non-combustible material, providing storage for non-hazardous safety equipment required by these regulations, may be permitted. Drinking water dispensers and ice cube machines may be permitted in corridors provided they are fixed and do not restrict the width of the escape routes. This applies as well to decorative flower or plant arrangements, statues or other objects of art such as paintings and tapestries in corridors and stairways. Identified crew stairwells with rubbish bins or housekeeping items stored. Cite: 74 SOLAS 20 11-2/5.3.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2026
Resolution: Items moved on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 May 2026 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, double-leaf doors equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. Fire door B.4.09 did not close one of the leaf's upon fire door release. Cite: 74 SOLAS 20 11-2/9 4.1.1.5.12
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2026
Resolution: Repaired on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 April 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. Fire door 5.2.11 on deck 5 closed faster than 10s. 74SOLAS20 II-2/9.4.1.1.5.2 16 A, B, C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 14 May 2025
Resolution: Received video showing fire door closing in appropriate time.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 April 2025 Resolved
Openings in bulkhead and decks in passenger ships. The following fire door listed below failed to indicate closed. A.1.2.1, A.2.01, 1.1.07, 1.1.08, 1.1.16, 2.2.05, 2.2.11, 2.3.06, 2.4.05, 3.2.11, 4.1.07, 4.1.08, 4.2.05, 4.3.08, 4.4.07, 4.4.05, 6.3.06, 6.3.07, 6.4.05, 6.4.09, 7.2.06, 7.2.08, 7.3.03, 7.4.02, 7.4.08, 8.4.01, 8.4.09 74SOLAS20 II-2/9.4.1 16 A, B, C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 13 May 2025
Resolution: Listed doors indicate closed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 April 2025 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. Sliding B door, deck 2, main vertical zone 4, port side near pantry and projectin room is not self closing and appears to have a broken cable. 74SOLAS20 II-2/9.4.1.2.1 16 A, B, C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 14 May 2025
Resolution: Received video showing pocket door closing properly.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 April 2025 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevent category having the most stringent boundary requirements. Storage items were found in 02 category 10 spaces. Emergency electrical locker 7.3.02 and emergency electrical locker 5.1.04 74SOLAS20 II-2/9.2.2.3.2.2 16 A, B, C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 13 May 2025
Resolution: Storage items have been taken out of the spaces.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2025 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Waste receptacles in crew smoking deck 9 and galley deck 7 aft made from combustible material. 74SOLAS20 II-2/4.4.2 16 A, B, C
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 13 May 2025
Resolution: Non-combustible waste recepticals are now placed in the spaces.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 April 2025 Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. Multiple pieces of galley equipment and a chair were on deck 7 aft service stair. 74SOLAS20 II-2/13.1.2 16 A, B, C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 14 May 2025
Resolution: Obstacles in the space were cleared.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 April 2025 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. Three mess cooks in seperate galley spaces were not familiar with the deep fryer fire extinguishing system and how and where it is activated. 74SOLAS20 II-2/15.2.2.1 16 A, B, C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 13 May 2025
Resolution: Training was conducted and verified.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.