Records from 2021 to 2025. Most recent: inspection, 23 June 2025.
Inspection history · 8
23 June 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8165035
8 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8107939
24 June 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7941048
4 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7681025
29 March 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7658630
18 April 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7433321
1 April 2021
Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7167211
17 February 2021
Deadweight Survey · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7160992
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2025
Resolved
The number and identification of the items stowed inside and their sizes must be clearly marked in legible letters and numbers on each container for lifejackets... Operator did not label the number of lifejackets for each container/area ensure all lifejacket stowage areas are labelled.
46 CFR 185.604
Action required: 705 - Other - as specified
Due 30 June 2025
Resolved 9 July 2025
Resolution: Vsl sent photo proof of properly labeled lifejacket stowage areas.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 May 2023
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place.
COI was not posted.
46 CFR 175.302, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 11 May 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 May 2023
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Stability letter was not posted.
46 CFR 176.306, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 11 May 2023
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and (5) Current tables
Required references were not provided.
46 CFR 184.420(a), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 11 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 4 May 2023
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
First aid kit contained expired items.
46 CFR 184.710, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 11 May 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 4 May 2023
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: [VERBIAGE STATED IN 33 CFR 155.450(a)]
Vessel did not have "discharge of oil prohibited" placard posted.
33 CFR 155.450(a), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 11 May 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 May 2023
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
No portable extinguishers are being subjected to monthly inspection.
46 CFR 176.810(b), 10c
Action required: 10 - Deficiency Rectified
Resolved 4 May 2023