MAURY USCG vessel records
← All vessels

GINGA LIGER

GINGA LIGER is a 2021 tank ship. The Coast Guard has recorded 6 inspections since 2021, most recently in November 2024, along with 1 deficiency.

Records from 2021 to 2024. Most recent: inspection, 29 November 2024.

Built
2021
Last inspected
29 November 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 November 2024
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2021–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9893448
9V6825
1656927
Flag
SINGAPORE
Maury page id
psix-1656927

Documentation record

Tonnage as PSIX records it15876 - Convention (Subpart B), Gross Ton
25064 - Dead Weight, Metric Ton
32311 - Displacement, Metric Ton
7369 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

29 November 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8039686
11 January 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7847013
11 January 2024 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7848122
18 December 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7610668
21 November 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7597589
17 May 2021 COC-CHEM & TVE Renew · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7195058

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 January 2024 Resolved
Testing shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. Vessel crew took an excess of 30 min to set the Emergency Fire Pump Running and another an excess of 35 min for foam monitors on deck.
Action required: 10 - Deficiency Rectified
Due 11 January 2024
Resolved 11 January 2024
Resolution: vsl provided SMS, see documents section.

Ownership record