KIMMSWICK
KIMMSWICK is a 2006 towing vessel. The Coast Guard has recorded 5 inspections since 2021, most recently in June 2025, along with 24 deficiencies.
Records from 2021 to 2025. Most recent: inspection, 11 June 2025.
- Built
- 2006
- Last inspected
- 11 June 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
AENA
1657661
Flag
UNITED STATES
—
Maury page id
psix-1657661
Inspections, by type
Years with a record
3 calendar years (2021–2025)
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it55 - Simplified, Gross Ton
37 - Simplified, Net Ton
37 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 5
11 June 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8129918
5 March 2025
Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8076173
4 May 2023
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7681915
15 March 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7640738
2 June 2021
Deficiency Check · Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7163555
Deficiency record · 24
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 March 2025
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.(b) Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. 03 fuel leaks were noted during inspection. Including a leak that was identified in 2023 (port main engine piping). Repair prior to movement
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 March 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High bilge levels and Low hydraulic steering fluid levels. The above alarms were inoperable during inspection. Repair prior to movement
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 March 2025
Resolved
An existing vessel may be deemed by the OCMI to be in compliance with this subpart provided that the vessel has been in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the [name withheld] discovered in the stern
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 March 2023
Resolved
General alarm (and alternative as described in 46 CFR 143.235(b)(4)) must have a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station”. Sign was missing in engine room.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 June 2021
Resolved
Vessel required to be fitted with general alarm (GA) or public address (PA) system meeting 46 CFR 143.235(b)(2)&(3). Vessel was not equipped with a GA or PA system meeting minimum requirements. Install proper GA or PA system meeting minimum requirements.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 June 2021
Resolved
Vessel required to be fitted with a fire pump. Fixed fire pump was incapable of delivering a stream of water meeting 46 CFR 142.325(a)(1). Repair and prove proper operation of fire pump.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 June 2021
Resolved
Fire alarm horn/strobe (high decibel audio & visual strobe light) located at operating station has potential to significantly distract master's ability to operate vessel in a safe manner during an emergency. Remove horn/strobe from operating station.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 June 2021
Resolved
Fire detection system required to be inspected or tested once every 12 months IAW 46CFR142.240(a). Vessel's system not serviced annually. Provide technician's report showing system properly serviced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 June 2021
Resolved
Fixed fire suppression system required to be inspected or tested once every 12 months IAW 46CFR142.240(a). Vessel's system not serviced annually. Provide technician's report showing system properly serviced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2021
Resolved
IAW definition of fixed fire suppression system the system is required to meet 46 CFR 76.15. 46 CFR 76.15(h) requires complete but simple instructions located near all pull boxes, stop valve controls, and in CO2 cylinder storage room. Instructions were not post. Post instructions as required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2021
Resolved
Portable fire extinguishers are required to be inspected or tested once every 12 months IAW 46CFR142.240(a). One CO2 portable fire extinguisher not tested/inspected annually. Extinguisher removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 June 2021
Resolved
Each integral fuel tank must have a vent fitted with a 30-by-30-mesh corrosion-resistant flame screen. Port side fuel tank vent flame screen was damaged. Repair or replace vent flame screen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 June 2021
Resolved
Auxiliary generator engines must be equipped with an RPM gauge at the machinery location. The vessel's generators were not equipped with RPM gauges. Properly install RPM gauges for each generator engine at machinery location.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 June 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency light in engine room failed to energize during inspection. Prove proper operation of engine room light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2021
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Shore tie connection (disconnected at time of inspection) did not have a cover to enclose outlet when not in use AND junction box (upper ER, port side) missing cover exposing wires. Install junction box cover and have cover available and in use when shore tie not connected.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 2 June 2021
Resolved
Piping for flammable or combustible liquid, seawater cooling, or firefighting systems must be fitted with isolation valves that are clearly marked by labeling or color coding that enables the crew to identify its function. Valves were not labeled nor piping marked. Properly label valves or mark piping.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 June 2021
Resolved
Portable, battery-powered lights must be located in the pilothouse and at the access to the engine room. Vessel did not have portable lights at these locations. Make portable lights available at these locations.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 June 2021
Resolved
Testing required for main propulsion engines and generator engines (high temperature and low lube oil pressure alarm set points), low hydraulic steering fluid level, day tank low fluid level, and air receiver relief valves. Testing not performed. Perform testing in presence of a USCG Marine Inspector and record in Towing Vessel Record.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 June 2021
Resolved
Work vest required to be approved by the Commandant under 46 CFR 160.053. Lifejacket worn by crew as a work vest did not meet 46 CFR 160.053. Remove from servcie lifejackts that are not approved for wear on board vessel (OCMI request for special consideration will be considered).
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2021
Resolved
Vessel does not operate under a stability document and must show satisfactory stability via history, operation tests, or through assessment.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 2 June 2021
Resolved
Employee assistance program (EAP) program requires training for crew member and supervisors. Records were not available to show completion of training. Make training records available for review.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 June 2021
Resolved
Illuminated magnetic compass required on vessel. Vessel not equipped with a magnetic compass. Install an illuminated magnetic compass (or swing meter) at the operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 June 2021
Resolved
Health and Safety plan required to include Falls Overboard information. Plan omitted Falls Overboard information. Include Falls Overboard information in the plan. (Corrected)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 June 2021
Resolved
Towing Vessel Record (TVR) required to include: personnel records, safety orientation, drills & instruction, examinations and tests, health and safety plan training, exams & tests, navigational assessments, navigational safety training, inspection of towing gear, lifesaving inspections, readiness & testing. Records have not been made in TVR. Make entries and show compliance with TVR requirements. Certain records may be kept on DREDGE POTTER if OCMI special consideration is requested in writing and approved.