Records from 2023 to 2025. Most recent: inspection, 23 September 2025.
Inspection history · 5
23 September 2025
COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8238074
14 September 2024
PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7987682
13 September 2024
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8002165
14 September 2023
COC-CVE Initial · PSC A · Polar Code Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7794731
15 May 2023
COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 7688441
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 September 2025
Resolved
74SOLAS20 II-2/9.4.1.1.5.2 10C 07105
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. Fire doors 3020 and 3024 closed too rapidly, they closed in 06 seconds.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 September 2025
Resolved 23 September 2025
Resolution: Rectified during exam.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 September 2025
Resolved
74SOLAS20 II-2/9.2.2.3.2.2 10C 07101
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevent category having the most stringent boundary requirements. Combustible materials were found in AC room 3030, which is categorized as a Cat 10 space.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 September 2025
Resolved 23 September 2025
Resolution: Rectified during exam.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 September 2023
Resolved
In interior locations in passenger ships, fire hoses shall be connected to the hydrants at all times. PSCO observed hoses not connected at: hydrant 813V104, 813V173 and 813V148.
74 SOLAS 20 II-2/10.2.3.1.1 (10c) Code 07110
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 September 2023
Resolved 21 September 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 September 2023
Resolved
The means olf escape shall be marked with light or photoluminescent strip indicators placed along an escape door. PSCO observed there was no photoluminescent strip in the escape door, deck 7 forward port and starbord leading to the bridge. 74 SOLAS 20 II-2/13.3.2.5.1(50c) Code 04103
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2023
Resolved 13 September 2024
Resolution: Recieved rectification documenation from master. No further CG action.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 21 September 2023
Resolved
Safety managment objectives of the company should provide for safe practices in ship operation and a safe working environment. PSCO observed a plastic tie around the door sensor which indicates that a water tight hatch door is closed on the bridge. Hatch was dogged open but indicating closure on the bridge. 74 SOLAS 20 IX/3.1(10c) Code 15101
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 September 2023
Resolved 21 September 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 21 September 2023
Resolved
A load line corresponding to the approved subdivision draught shall be assigned and marked on the ships sides. PSCO observed deckline was present but not marked in contrasting colors. 74 SOLAS 20 II-1/18.1 (10c) Code 03102
Action required: 10 - Deficiency Rectified
Due 21 September 2023
Resolved 21 September 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 September 2023
Resolved
The following functional requirements shall be met. Escape routes shall be maintained in safe condition, clear of obsticles. PSCO observed stairway on deck 3 had a table tennis game secured to the stairway rail.
74 SOLAS 20 II-2/13.1.2(10c) Code 07120
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 September 2023
Resolved 21 September 2023