Records from 2021 to 2025. Most recent: inspection, 21 October 2025.
Documentation record
Registered dimensions (L × B × D)40.6 ft × 16.5 ft × 2.2 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS INC · CHRISTIANSTED, VI, UNITED STATES · built 2021
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portCHRISTIANSTED, VI
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
21 October 2025
Annual Inspection · Examination of Repairs · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8255942
11 June 2025
Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8150603
10 February 2025
Examination of Repairs · In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8077993
19 August 2024
Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7982898
25 October 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7801831
24 July 2023
Drydock Exam · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7747481
10 April 2023
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7666319
10 April 2023
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7672343
2 November 2022
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7588132
13 October 2022
Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7572593
5 October 2021
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7326943
24 May 2021
Administrative Inspection · Deadweight Survey · Drydock Exam · Construction Oversight · COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7205034
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 October 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a bilge well. The vessel's four bilge high level alarms were found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2025
Resolution: New switches were installed on each of the vessel's four bilge high level alarms.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 October 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wiring was noted under the operating station console.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 18 December 2025
Resolution: The open wires have been cut and closed off.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 October 2025
Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06 and must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a Serious Marine Incident. Alcohol testing devices were not available for inspection.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 8 December 2025
Resolution: Three alcohol test strips were made available for inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 October 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. The two flashlights were inoperable due to dead batteries.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 29 October 2025
Resolution: New batteries have been installed in the lights and they are operational.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 21 October 2025
Resolved
Abandon ship, man overboard, and fire fighting drills, conducted every three months, and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training and a general description of the drill scenario and training topics. The vessel has not logged fire fighting drills and other drill logs do not contain detailed information.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 29 October 2025
Resolution: Appropriate logs have been made for drills conducted on 22OCT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 October 2025
Resolved
Each EPIRB must be tested monthly, which shall be logged or otherwise documented. Vessel representative could not provide a log or documentation of EPIRB tests.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 8 December 2025
Resolution: EPIRB tests are being documented in the vessel's log.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 21 October 2025
Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates to be issued by the FCC in 47 CFR Part 80. Vessel is required to have a crewmember with a valid FCC operator permit. Keyinde McIntosh does not possess a permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2025
Resolved 17 December 2025
Resolution: Key provided proof of his marine radio operator permit.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 21 October 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not mounted or otherwise available on the vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 29 October 2025
Resolution: The existing copy of emergency instructions has been posted on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets, with an attached lanyard, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. The fire buckets maintained on board were all in excess of the required size.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2024
Resolved 5 September 2024
Resolution: Operator provided pictures of large holes drilled in the fire buckets at the 2.5gallon mark.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 October 2023
Resolved
A vessel required to have an EPIRB must have a FCC
type accepted category 1, 406 MHz EPIRB, installed
to automatically float free and activate. Hydrostatic
release had expired the previous month.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2023
Resolved 26 October 2023
Resolution: Owner replaced hydrostatic release with a new unit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 April 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel must prove to marine inspector that cause has been repaired and repairs are satisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2023
Resolved 11 April 2023
Resolution: Vessel has gotten a new hydraulic hose. Conducted sat sea trial.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 October 2022
Resolved
Certification or licensing by a state or local jurisdiction as a fire extinguishing servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirement of NFPA 10 for annual maintenance and recharging of extinguishers. Current inspection stickers or paperwork must be provided to OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 14 October 2022
Resolution: Vessel has received fire extinguisher inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021
Resolved
Vessel was not documented nor had a the proper state registration.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2021
Resolved 5 October 2021
Resolution: State regristration has been provided during inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021
Resolved
Vessel has not recieved it's stability letter.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2021
Resolved 16 August 2021
Resolution: Vessel recieved Stability letter from MSC.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 May 2021
Resolved
Vessel's crew must perform drills for CG inspectors.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2021
Resolved 5 October 2021
Resolution: Vessel crew conducted fire, man over board and abandon ship drills.