MAURY USCG vessel records
← All vessels

PERTAMINA GAS 1

PERTAMINA GAS 1 is a 2013 tank ship. The Coast Guard has recorded 5 inspections since 2021, most recently in July 2025, along with 6 deficiencies.

Records from 2021 to 2025. Most recent: inspection, 25 July 2025.

Built
2013
Last inspected
25 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 July 2025
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2021–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9643348
1660680
Flag
INDONESIA
Maury page id
psix-1660680

Documentation record

Tonnage as PSIX records it48917 - Convention (Subpart B), Gross Ton
48917 - Regulatory (Subpart C or D), Gross Ton
54627 - Dead Weight, Ton
48917 - Displacement, Ton
16576 - Convention (Subpart B), Net Ton
16576 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

25 July 2025 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8187418
29 January 2024 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7848684
20 November 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7597413
18 November 2022 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7593895
23 July 2021 COC-GAS Renew · PSC A · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7246948

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2025 Resolved
A gas carrier shall comply with the requirements of the International Gas Carrier Code and shall, in addition to the requirements of regulation I/8, I/9, and I/10, as applicable, be surveyed and certified as provided for in that Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. Electrical installations should be such as to minimize the risk of fire and explosion from flammable products*. Electrical installations complying with this chapter need not be considered as a source of ignition for the purposes of chapter 3. PSCO Observed over 90% of explosion proof lighting in the cargo compressor room having cracked covers, explosion proof light above above compressor room port side entrance door missing appropriate hardware.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2025
Resolved 26 July 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 25 July 2025 Resolved
A gas carrier shall comply with the requirements of the International Gas Carrier Code and shall, in addition to the requirements of regulation I/8, I/9, and I/10, as applicable, be surveyed and certified as provided for in that Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. Gas detection equipment should be so designed that it may readily be tested. Testing and calibration should be carried out at regular intervals. Suitable equipment and span gas for this purpose should be carried on board. Where practicable, permanent connections for such equipment should be fitted. PSCO observed crew test fixed gas detection from compressor room and produced LEL % reading of over 100% thus indicating equipment is not properly calibrated. Crew conducted calibration on 08 July 2025 however crew certification could not be produced.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 August 2025
Resolved 26 July 2025
14 - Pollution Prevention › 148 - Ballast Water › Ballast water discharge
Issued 25 July 2025 Resolved
To discharge ballast water into waters of the United States, the master, owner, operator,agent, or person in charge of a vessel subject to § 151.2025 of this subpart must either ensurethat the ballast water meets the ballast water discharge standard as defined in § 151.2030(a),use an AMS as described in § 151.2025(a)(3) or ballast exclusively with water from a U.S.public water system, as described in § 151.2025(a)(2), according to the schedule in paragraph(b) of this section. Subject Vessel (keel laid date 20DEC2012) and capacity of 23512.1 m3 remains inoperable, per vessels self-report.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 September 2025
Resolution: BV issued survey statement and completion of repairs.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 18 November 2022 Resolved
Airlock doors should be self-closing and without any holdback arrangements. PSCO observed holdback arrangements and a non-operational self-closing device on the motor room door. 50ac SOLAS (09CONSED) CH VII regulation 13.1 IGC Code (93ED) CH 3.6.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2022
Resolved 20 November 2022
Resolution: Vessel provided pictures of self closing device on motor room replaced with new device and holdback arrangement cut from bulkhead
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 18 November 2022 Resolved
Gas detection equipment should be so designed that it may be readily tested. Crew members unable to demonsonstrate to PSCO satisfactory L.E.L. test on vessel's installed fixed gas sampling system. 17ac SOLAS (09 CONSED) Ch VII Regulation 13.1 IGC Code (93ED) CH 13.6.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2022
Resolution: Received tech report. Def closed
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 July 2021 Resolved
PRESSURE RELIEF VALVES SHOULD BE SET AND SEALED BY A COMPETENT AUTHORITY ACCEPTABLE TO THE ADMINISTRATION. PSCO FOUND TWO MARVS THAT HAD BROKEN SEALS. 74 SOLAS (20) VII/13.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 July 2021
Resolved 10 September 2021
Resolution: Reviewed class report attesting repair.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.