Records from 2021 to 2025. Most recent: inspection, 6 December 2025.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 20.0 ft × 4.8 ft
Registered tonnagegross 16 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSENTINEL BOAT LLC · WETUMKA, AL, UNITED STATES · built 2021
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portNORTH MYRTLE BEACH, SC
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationCase Pending · issued 3 May 2021
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
6 December 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8278526
28 October 2025
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8259129
23 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8257469
8 May 2025
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8123771
12 March 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8092391
31 January 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8072914
6 January 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8058984
5 December 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8043955
4 June 2024
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7927527
11 January 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7871357
28 February 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7643482
30 November 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7600579
24 June 2022
Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7486038
9 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7408781
25 May 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7206115
10 May 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7193733
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 6 December 2025
No resolution recorded
Employers must ensure that they and their crew members meet the requirements of this part.
Vessel was found near Bahia Mar without all crew members enrolled in a chemical testing program. Voyage terminated and restricted from carrying passengers until CG verifies list of crew are in good standing and on the covered employees list.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 March 2025
Resolved
Vessels with engines powered by gasoline must not be constructed with general purpose resin, except for vessels powered by outboard engines with portable fuel tanks stored in an open area aft, if, as determined by the cognizant OCMI, the arrangement does not produce an unreasonable hazard. Vessel was constructed with general purpose resin and has a permanently installed 200 gallon aluminum gasoline tank on the stern deck of the vessel. Submit written plans for approval prior to the carriage of passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 April 2025
Resolution: Received objective evidence of 2 installed 40-B:C fire extinguishers.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 13 February 2025
Resolved
The marine employer must have sufficient number of alcohol testing devices readily accessible... Testing devices need not be carried on board each vessel if obtaining the devices and conducting the required alcohol tests can be accomplished within 2 hours from the time of occurrence of SMI. Alcohol swabs at office found expired, owner/operator to replace and provide proof of replacements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 27 February 2025
Resolution: Received receipts of new alcohol swab purchase and verbal confirmation replaced at office w/i two hours of testing capability.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 February 2024
Resolved
Rail courses or the equivalent must be installed between a top rail required of this section, and the deck so that no open space exists that is more than 4" between bars, slats, rail courses, or an equivalent on a vessel on an excursion trip. Marine Inspector observed a bar on the forward railing on the tope deck to be broken. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 12 April 2024
Resolution: Vessel rep supplied picture evidence of repaired rail. Marine Inspector examined and found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 February 2024
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel. Marine Inspector observed mounting screws holding the railing to the deck to be loose. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 12 April 2024
Resolution: Vessel rep supplied picture evidence of repaired rail. Marine Inspector examined and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2023
Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided... Vessel is missing 2 child size lifejackets. Vessel is permitted to carry only 4 children.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 March 2023
Resolution: Received photographic evidence of proper number of lifejackets onboard.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 February 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Emergency fuel shutoff handles wasted. Replacement required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2023
Resolution: Received video of replaced and operable fuel shutoff valve handles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Port bow bilge pump is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2023
Resolution: Received video footage of operable bilge pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 February 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking. Vessel missing marking denoting maximum number of persons allowed on upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2023
Resolution: Max pax label installed.