Tonnage as PSIX records it53688 - Dead Weight, Ton 18825 - Convention (Subpart B), Net Ton 19726 - Displacement, Ton 46789 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 8
9 March 2026PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8323392
22 September 2024COC-GAS Annual · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7999303
28 August 2023COC-GAS Renew · PSC B · Administrative Inspection
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 March 2026Resolved
Electrical installations should be such as to minimize risk of fire and explosion from flammable products.
PSCO observed 05 cracked lights in cargo compressor room and 01 light installed without proper packing glands for wiring. Additionally, observed loose wiring on light at tank top #3.
74SOLAS(20) III/13.1
IGC(93) 10.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2026
Resolution: Received class report from vessel stating all repairs were conducted to satisfaction of class and was sufficient evidence for our office to clear deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 September 2024Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLWOING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS.
PSCO OBSERVED ATOMIZED FUEL SPRAYING FROM #1 GENERATOR FUEL SUPPLY LINE.
74SOLAS(20)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 23 September 2024
Resolution: RECEIVED CLASS SURVEYOR REPORT ATTESTING TO SATISFACTORY REPAIRS OF #1 GENERATOR FUEL LINE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 September 2024Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO HOT SURFACES AND OTHER HAZARDS.
PSCO OBSERVED EXCESSIVE OIL LEAKING FROM THE #3 GENERATOR OIL COOLER INTO A CATCH PAN BENEATH THE LUBE OIL COOLER.
74SOLAS(20)II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 December 2024
Resolved 23 September 2024
Resolution: RECEIVED CLASS SURVEYOR REPORT ATTESTING TO SATISFACTORY REPAIR OF #3 GENERATOR LUBE OIL COOLER.
THE DOORS SHOULD BE SELF-CLOSING AND WITHOUT ANY HOLDBACK ARRANGEMENTS. THE MOTOR ROOM'S AIRLOCK DOORS SELF-CLOSING DEVICE WAS INOPERATIVE AND UNAUTHORIZED HOLDING DEVICE WAS INSTALLED.
74 SOLAS (20) VII/13.1
IGC CODE (93) 3.6.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 June 2021
Resolved 19 June 2021
Resolution: Class Report.