MAURY USCG vessel records Sign in
← All vessels

MAYA

MAYA is a 1979 offshore supply vessel. The Coast Guard has recorded 23 inspections since 1990, most recently in April 2000, along with 16 deficiencies.

Records from 1990 to 2000. Most recent: inspection, 20 April 2000.

Built
1979
Last inspected
20 April 2000
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7816630 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WAJ5352
166865
Flag
UNITED STATES
366729470 (licence lapsed)
Maury page id
psix-166865

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (1990–2000)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)63.5 ft × 34.0 ft × 6.8 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHALTER MARINE INC · CHICKASAW AL, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 January 1992 · expires 31 January 2001
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAJ5352MMSI 366729470 · expired · compulsorily equipped · granted 3 February 1997, cancelled 7 April 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

20 April 2000 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 817518
25 January 2000 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070625
18 August 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777625
8 June 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360938
8 July 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1129054
7 May 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125759
30 April 1998 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460194
12 May 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451196
12 November 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 220403
6 May 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1083258
6 May 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363611
21 April 1995 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363268
5 May 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377172
1 March 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1164490
14 May 1993 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389653
1 May 1992 COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1270982
14 January 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955958
17 June 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032803
23 May 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903993
20 December 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1221031
16 November 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223603
31 August 1990 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226262
11 May 1990 Deadweight Survey · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232824

Deficiency record · 16

Lifesaving
Issued 8 June 1999 Resolved
PROVIDE CG APPROVED EMBARKATION LADDER UNDER 46 CFR 160.017 FOR EMBARKATIONINTO RESCUE BOAT.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Lifesaving
Issued 8 June 1999 Resolved
REPLACE LIFEFLOATS OR PROVIDE NEW WEBBING FOR EXISTING LIFEFLOATS. WEBBINGFOR NET SHALL BE EQUAL TO EXISTING MATERIAL.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Lifesaving
Issued 8 June 1999 Resolved
PROVIDE 2 EA ASME APPROVED POP OFF VALVES BETWEEN COMPRESSORS AND INLET VALVES ON AIR RECEIVERS. VALVES TO BE 150 PSI OR LOWER.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Deck/Cargo
Issued 30 April 1998 Resolved
PROVIDE UT REPORT ON ALL HYDRAULIC OIL LINES INSIDE VOID SPACES.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Fire Fighting
Issued 30 April 1998 Resolved
PROVIDE PROPER FIRE EXTINGUISHER BRACKETS THROUGHOUT VESSEL.
Condition: Unknown
Due 30 May 1998
Resolved 11 August 1998
Navigation
Issued 30 April 1998 Resolved
PROVE PROPER OPERATION OF NAV LIGHT PANEL.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Construction/Loadline
Issued 30 April 1998 Resolved
PROVIDE UT REPORT ON AFT BULKHEAD OF #2 VOID.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Engineering
Issued 30 April 1998 Resolved
PROVE PROPER OPERATION OF ALL ENGINE ALARMS ON BRIDGE.
Condition: Unknown
Due 30 May 1998
Resolved 13 May 1998
Navigation
Issued 23 May 1991 Resolved
REMOVE BUNKS (8 TOTAL) FROM BERTHING AREAS ON 01 DECK TO UNBLOCK TONNAGE_x001C_ OPENINGS. (BUNKS ARE ADJACENT TO TONNAGE OPENINGS)
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Navigation
Issued 23 May 1991 Resolved
PROVIDE ON BOARD CURRENT DEVIATION CARD FOR MAGNETIC COMPASS.
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Documentation
Issued 11 May 1990 Resolved
PROVIDE ON BOARD A ROUGH COPY OF AN OPERATIONS MANUAL MEETING APPLICABLE SECTIONS OF 46 CFR 109.121.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Documentation
Issued 11 May 1990 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Deck/Cargo
Issued 11 May 1990 Resolved
PROVIDE ON BOARD FOR PORT CRANE A PERMANENT LOAD CHART AND ANGLE INDICATOR.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Documentation
Issued 11 May 1990 Resolved
SUBMIT STABILITY INFORMATION FOR ISSUANCE OF STABILITY LETTER TO U.S. COAST GUARD MARINE SAFETY CENTER.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Documentation
Issued 11 May 1990 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Documentation
Issued 11 May 1990 Resolved
PROVIDE ON BOARD A READMEASUREMENT CERTIFICATE AND A COAST GUARD DOCUMENT SHOWING LOWERED TONNAGE.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.