Records from 1991 to 2017. Most recent: inspection, 31 August 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
31 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6256174
20 July 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5190477
19 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4822498
1 February 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3937058
18 January 2011
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3928050
19 January 2010
Ballast Water Examination · Examination of Repairs · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3666042
16 January 2009
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3395158
5 August 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3289930
5 March 2008
Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3158594
6 February 2007
Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2867971
23 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2860310
20 April 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2629008
23 January 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2571349
2 March 2005
Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2301922
9 September 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2191214
18 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2008386
24 March 2003
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1761857
30 July 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1663440
20 February 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457919
11 April 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1048750
16 March 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421817
7 April 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 3360
5 January 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472236
16 September 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388567
20 June 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932915
23 March 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446188
12 August 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669636
11 July 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213002
11 July 1994
Re-Inspection · Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398095
24 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 859581
19 March 1993
Inclining Experiment · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393915
11 March 1991
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217494
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 January 2011
Resolved
Latch for stove needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 January 2011
Resolution: Crew installed a securing device to stove.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 18 January 2011
Resolved
E/R ladder needs repaired. Top right support is cracked.
Action required: 705 - Other - as specified
Resolved 26 January 2011
Resolution: Shipyard repaired ladder.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 18 January 2011
Resolved
MSD approval plate placard is missing. Vessel advised to procure new approval plate.
Action required: 705 - Other - as specified
Resolved 26 January 2011
Resolution: New plate was installed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 18 January 2011
Resolved
Replace hydraulic hoses as indicated by inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 January 2011
Resolution: Hoses were replaced.
Construction/Loadline › Hull › Bracket
Issued 18 January 2011
Resolved
Replace cracked gussets as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 26 January 2011
Resolution: Gussets were replaced.
Construction/Loadline › Hull › Stiffener
Issued 18 January 2011
Resolved
Replace wasted angles near rudders.
Action required: 705 - Other - as specified
Resolved 26 January 2011
Resolution: Angles were replaced.
Engineering › Steering Gear System › Piping
Issued 18 January 2011
Resolved
Provide report of hydraulic system after identifying several areas chaffed from metal to metal contact. Replace all chaffing material. Provide support for lines as indicated. Remove unions and replace with bolted flanges if under pressure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2011
Resolution: Report provided, supports were welded in to prevent vibration, and unions were replaced with bolted flanges.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 January 2011
Resolved
Battery boxes contain water. Crew instructed to remove.
Action required: 705 - Other - as specified
Resolved 26 January 2011
Resolution: Crew removed water.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 18 January 2011
Resolved
Audible bilge alarm was inop. Found several loose wires inside alarm box. Crew to repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2011
Resolution: Bilge audible alarm was cut. Crew repaired.
Engineering › Lubricating Oil Service System › Hose
Issued 6 February 2007
Resolved
Demonstrate compliance with 46 CFR 56 & 58.30 as required by NVIC 8-91, all components of jacking system meet system operating pressures and system is "fail safe".
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 29 April 2008
Resolution: Letter provided documenting compliance (attached to case).
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 January 2006
Resolved
Vessel operated outside the terms of COI in that carried more persons on board than authorized by vessel's COI, issued NOV.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 5 August 2008
Resolution: Cleared
Construction/Loadline › Hull › Hull Plating
Issued 24 March 2003
Resolved
Crop and renew as original wasted hull plate in way of deck and side shell as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2003
Resolution: Plate renewed and completed satisfactory dye pen test.
Lifesaving › Lifebuoys
Issued 24 March 2003
Resolved
Replace worn life ring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2003
Resolution: Life ring replaced.
Stability › Watertight Integrity
Issued 24 March 2003
Resolved
Adjust watertight escape hatches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2003
Resolution: Hatches adjusted.
Fire Fighting › Ventilation Systems
Issued 24 March 2003
Resolved
Renew gasket in vent closures on main deck. LEGACY COMPONENT DESC: Duct Hatches
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2003
Resolution: Gaskets replaced.
Accommodation/Occupational Safety
Issued 11 March 1991
Resolved
PROVIDE DECK DISCHARGE, 3/4 FULL INDICATOR FOR SEWAGE HOLDING TANK, AND CHAIN LOCK BYPASS VALVE. STENCIL "DO NOT OPEN VALVE IN U.S. WATERS".
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Documentation
Issued 11 March 1991
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEG AND LEG TOWER SUPPORTS TO [name withheld].
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Documentation
Issued 11 March 1991
Resolved
SUBMIT STABILITY CALCULATIONS TO THE COAST GUARD MARINE SAFETY CENTER FOR ISSUANCE OF A STABILITY LETTER.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Documentation
Issued 11 March 1991
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE PARTS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991