MAURY USCG vessel records Sign in
← All vessels

TRIUMPH III

TRIUMPH III is a 1979 passenger vessel (inspected). The Coast Guard has recorded 99 inspections since 1986, most recently in April 2026, along with 104 deficiencies, 1 operational control and 8 casualty investigations between 2004 and 2025.

Records from 1986 to 2026. Most recent: inspection, 3 April 2026.

Built
1979
Last inspected
3 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBF3346
167182
Flag
UNITED STATES
367177670
Maury page id
psix-167182

Inspections, by type

…with no type recorded10
Years with a record 37 calendar years (1986–2026)
The 99 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.2 ft × 13.8 ft × 6.4 ft
Registered tonnagegross 25 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBF3346MMSI 367177670 · active · compulsorily equipped · granted 24 January 2017, expires 10 April 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 99

3 April 2026 Deficiency Check · Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8341566
17 December 2025 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8284951
15 December 2025 Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8284042
15 December 2025 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8291699
10 December 2025 Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8282096
27 October 2025 DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8257206
4 April 2025 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8105295
14 January 2025 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8064511
28 August 2024 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7991528
29 January 2024 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7857424
17 November 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7826429
15 November 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7825453
19 February 2023 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7638870
10 November 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7592404
7 June 2022 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7471091
11 October 2021 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7330609
27 September 2021 Damage Survey · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7321600
27 September 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7331466
6 August 2021 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7279394
3 August 2021 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7274995
16 March 2021 Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7205881
25 August 2020 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7049121
30 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7042422
21 November 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6860342
22 April 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6672954
2 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6654165
30 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6495543
14 May 2018 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6414247
5 April 2018 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6385244
7 September 2017 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6265380
20 June 2017 Simplified Stability Test
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6182570
23 May 2017 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6153483
12 April 2017 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6124091
30 January 2017 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6080004
18 October 2016 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6026308
12 September 2016 Examination of Repairs · Administrative Inspection · Damage Survey · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5998825
26 April 2016 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5863073
16 March 2016 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5834576
11 February 2016 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5814617
18 August 2015 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5221630
17 August 2015 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5221775
20 July 2015 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5161970
30 July 2012 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4395286
16 May 2012 Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4313209
13 May 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4311541
28 February 2012 Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4252187
24 January 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4211698
8 December 2011 Simplified Stability Test
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4203150
2 December 2011 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4200180
27 September 2011 Plan Review "T" Boat · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4155405
12 August 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4177248
2 August 2011 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4072727
9 September 2010 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3827524
7 December 2009 Damage Survey · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3646461
22 January 2009 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3403941
16 January 2009 Examination of Repairs · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3394777
15 January 2009 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3397934
3 January 2009 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3391590
24 July 2008 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3276819
24 July 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3290114
4 May 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2998682
5 April 2007 Deficiency Check · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2899996
20 January 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2875662
1 June 2006 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2664321
25 January 2006 Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2574722
16 June 2005 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2367341
16 August 2004 Simplified Stability Test · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2168132
3 August 2004 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2114331
28 June 2004 Examination of Repairs · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2088579
23 May 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2235728
18 June 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1846442
7 May 2003 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1785157
29 April 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1779092
18 October 2002 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1692010
17 April 2002 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1600822
1 June 2001 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1391571
1 June 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1049540
1 May 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1389069
13 July 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1100169
4 June 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 805959
3 May 1999 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 802633
1 May 1998 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1388533
28 May 1997 Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1112437
5 May 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1435922
20 August 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1087200
8 July 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1088402
25 June 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1084879
20 June 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1079783
28 May 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1430209
2 June 1995 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1420976
15 June 1994 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1439517
21 May 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1393953
23 July 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 955325
29 June 1992 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1256101
23 April 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1263132
30 May 1989 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1230774
1 July 1988 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1208049
27 May 1987 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1334572
30 May 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293465

Deficiency record · 104

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2026 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. The vessel reported colliding with a log. Vessel is required to haul out and rectify any damage satisfaction of the attending Marine inspector.
Action required: 10 - Deficiency Rectified
Due 3 April 2026
Resolved 3 April 2026
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 December 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. On December 15, 2025 vessel reported while conducting mooring operations they allided with the slip causing approximately a 2-3 inch hole in their port bow about 4 feet above the waterline. Vessel is required to repair hole to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2025
Resolved 17 December 2025
Resolution: Vessel repaired to the satisfaction of the Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 27 October 2025 Resolved
47 CFR 80.903 Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2025
Resolved 3 November 2025
Resolution: Vessel Operator provided a valid FCC Radio Safety Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 January 2025 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was found overdue for its annual COI. Vessel must recieve inspection prior to commercial operations.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 14 January 2025
Resolved 14 January 2025
Resolution: Vessel scheduled and recieved annual COI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 January 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. On January 28, 2024 the vessel reported colliding with a log. Vessel is required to haul out, and remain available for a complete inspection of the underwater body and appendages to the satisfaction of the attending Marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2024
Resolved 30 January 2024
Resolution: Replace port and starboard propeller.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2023 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Logs were not maintained to prove that monthly inspections were taking place. Perform maintenance IAW NFPA 10 and log to the satisfaction of the Marine Inspector. 46 CFR 176.810(b)
Action required: 10 - Deficiency Rectified
Due 17 November 2023
Resolved 17 November 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 November 2023 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Observed two holes in fwd bulkhead of engine room. Repair holes to the satisfaction of the Marine Inspector. 46 CFR 176.25-50(a) (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2023
Resolved 10 January 2024
Resolution: Proof of temporary repair until next drydock was provided. Moving this item to special note.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 November 2023 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Observed and marked two popped welds in lazarette where aft bulkhead meets the deck plating. Repair welds to the satisfaction of the Marine Inspector. To be corrected at earliest drydock. 46 CFR 176.25-50(a)(Old T)
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Weld were repaired to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel has 14 life jackets on board. Add enough life jackets to fulfill the requirements of the COI. Vessel is currently restricted to a maximum of 12 passengers until rectified. 46 CFR 180.71(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2023
Resolved 14 December 2023
Resolution: Verssel added new lifejackets fulfilling COI requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 November 2023 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Vessel has not received or requested annual inspection within allowable time-frame. Submit application for inspection to local OCMI. **This vessel is restricted from further operations under the authority of the COI until the Coast Guard has completed the required inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2023
Resolved 17 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2022 Resolved
Shutoff valves shall be installed so as to close against the fuel flow. Observed inoperable fuel shutoff valve. Repair or replace to satisfaction of attending marine inspector. 46 CFR 182.455 (b)(4)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2022
Resolved 10 November 2022
Resolution: VSL repaired fuel shutoff vlave, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2022 Resolved
Steering gear shall be of adequate strength and capable of steering the vessel at all service speeds. Observed improper instillation of steering gear with missing bushing and loose hydraulic ram. Repair or replace to satisfaction of attending marine inspector.46 CFR 182.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2022
Resolved 21 November 2022
Resolution: Rcvd photos of fixed steering system bushings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2022 Resolved
Breaker for the generator in the engine room has no visible markings to identify amperage rating or UL489 areal standard. Conductors must be protected in accordance with their current carrying capacities. Each circuit breaker must meet UL 489. Provide verification the installed breaker meets these requirements or replace with one that does. Vessel shall not operate with passengers and cargo while running generator.46 CFR 111.54-1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 December 2022
Resolved 21 November 2022
Resolution: Proof of UL489 listing was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 October 2022 Resolved
Supply and return fuel hoses on new generator installation are USCG Type A1, but exceed the 30 inch limitation of use. Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 or be specifically approved by the Commandant. Replace with SAE J-1942 hoses.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2022
Resolution: VSL installed compliant hoses to satisfaction of attending marine inspector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 October 2022 Resolved
The engine room generator breaker box is grounded via jumper to generator grounding cable. Electrical equipment on a vessel must be installed and maintained to Provide services necessary for safety under normal and emergency conditions.... Remove jumper cable and provide repair proposal for grounding breaker box.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2022
Resolution: cleared and reissued to allow for operation while generator is not running
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 June 2022 Resolved
Breaker for the generator in the engine room has no visible markings to identify amperage rating or UL 489 approval standard. Conductors must be protected in accordance with their current carrying capacities. Each circuit breaker must meet UL 489. Provide verification the installed breaker meets these requirements or replace with one that does.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2025
Resolution: During annual examination found the main breaker to be compliant with UL listing and had all circuits labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2021 Resolved
The port side shaft sheered due to an installation error of the propeller.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2021
Resolved 14 October 2021
Resolution: Propeller bored to fit up to the end of the taper, and a spacer installed between propeller and the locking nuts.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 July 2020 Resolved
SM01: Vessel is required to have on board a valid FCC Safety certificate for each VHF radio, as per 47 CFR 80.401. Vessel does not have FCC Safety certificate onboard. Obtain FCC safety certificate for vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2020
Resolved 24 September 2020
Resolution: Provided photocopy of Safety Radio Certificate
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 July 2020 Resolved
SM02: Vessel is required to have on board a valid FCC station license for each VHF radio, as per 47 CFR 80.405. Vessel does not have a FCC station license on board. Obtain FCC station license.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2020
Resolved 4 September 2020
Resolution: Provided copy of Radio Station Authorization, which was issued on 24JAN2017.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 July 2020 Resolved
SM03: Each life jacket must be marked with Type I retroreflective material. 01 life jacket's retroreflective material is partially torn from the seams. Replace retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2020
Resolved 29 August 2020
Resolution: Received photo of the replacement of the life jacket with excessively worn retroreflective material.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 July 2020 Resolved
SM04: Vessel must have operable masthead light. Masthead light is inoperable. Make masthead light operable prior to operating at night or low visibility conditions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2020
Resolved 31 July 2020
Resolution: Photo of operable masthead light emailed to inspector. Deficiency cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 30 July 2020 Resolved
SM05: Waste receptacles must be constructed of non combustible materials. 02 trash cans on vessel must be replaced with non combustible waste receptacles.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2020
Resolved 25 August 2020
Resolution: Received photo from master of replaced trash can.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 July 2020 Resolved
SM06: Wiring must be installed with metal supports spaced not more than 24 inches apart. Bilge alarm wiring in 2nd space from the bow must be properly installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2020
Resolved 25 August 2020
Resolution: Received photos from master of installed supports for bilge alarm wiring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019 Resolved
CR01: 02 SAE J-1942 hoses worn and require replacement.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 22 April 2019
Resolution: Verified new hoses had been installed in engine compartment to resolve CG-835 item CR01
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 2 April 2019 Resolved
CR02: FCC Operator License expired and requires renewal.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 21 November 2019
Resolution: Recieved proof of FCC licenses.
Documentation › Certificates/Documents › FCC SSL
Issued 5 April 2018 Resolved
KK01- FCC Station License expired and requires renewal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 July 2018
Resolution: Received satisfactory copy of certificate.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 April 2018 Resolved
KK02- FCC Safety Certificate expired and requires renewal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 July 2018
Resolution: Received satisfactory copy of certificate.
Engineering › Sea-water System (primary cooling) › Pump
Issued 7 September 2017 Resolved
01ERH: Vessel experienced high temp alarm on port engine while underway. Complete repairs to port engine prior to operating passengers. Underway operational test required in presence of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2017
Resolution: Raw water impeller replaced on the port engine and operational test completed. All sat.
Construction/Loadline › Hull › Hull Plating
Issued 23 May 2017 Resolved
Make vessel available for inspection (shaft and propeller), post striking submerged object.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2017
Resolved 24 May 2017
Resolution: Marine Inspectors attended the vessel out of the water. Propellers replaced, no other damage noted. Operator conducted sea trials and provided written statement as to the satisfactory operation of the vessel. (Included in documents).
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 12 April 2017 Resolved
It was reported that the vessel struck a log and is experiencing vibrations while underway. Pull the vessel out of the water to inspect propeller and conduct runout readings of shaft in presence of marine inspector. 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2017
Resolved 13 April 2017
Resolution: Completed satisfactory run out readings of both shafts. Both propellers were replaced.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 30 January 2017 Resolved
HO01: Make hull available, in dry-dock status, to attending Marine Inspector in order to conduct post casualty survey prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 31 January 2017
Resolution: Witnessed new propellers installed on vessel & received documentation attesting to a satisfactory function test.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 October 2016 Resolved
The FCC Safety Radiotelephony Certificate onboard is out of date. Obtain valid FCC Radiotelephony Certificate and email proof of complaince to [email withheld] as per 47CFR80.903.
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 30 January 2017
Resolution: Recieved notification from operator that the FCC radiotelephony certificate was updated and onboard the vessel.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 12 September 2016 Resolved
SUBMIT REPAIR PROPOSAL FOR PROP AND SHAFT DAMAGE. COMPLETE ALL REPAIRS IAW APPROVED REPAIR PROPOSAL. PROVE PROPER OPERATION OF PROPULSION AND STEERING TO SATISFACTION OF USCG MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2016
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 26 April 2016 Resolved
Damage to propeller, stern tube, stern bearing from log strike. Also identified damaged starboard clevis, potential leak in fuel tank, delamination on port stern bearing, and cracked welds on starboard transom stiffiner.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 13 May 2016
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 16 March 2016 Resolved
Vessel's port propeller severly damaged and needs to be replaced in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2016
Resolved 16 March 2016
Resolution: Replaced stbd propeller.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 11 February 2016 Resolved
Vessel's port propeller severly damaged and needs to be replaced in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2016
Resolved 11 February 2016
Resolution: Replaced port and stbd propellers.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 August 2015 Resolved
Vessels starboard shaft broke and needs to be replaced like in kind - 46CFR176.670
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2015
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 July 2012 Resolved
HO 02 Ensure engine room and steering room bilge alarms have separate indicating lights. 46 CFR 182.530 30 Aug 12
Action required: 705 - Other - as specified
Due 30 August 2012
Resolved 31 August 2012
Engineering › Fuel Oil Service System › Filter
Issued 30 July 2012 Resolved
HO 01 Add flame impingment shileds or metal bowls to engine fuel filters (QTY of 4) 46 CFR 182.455(b)(6)
Action required: 705 - Other - as specified
Due 30 August 2012
Resolved 20 September 2012
Resolution: Flame shields have been added.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 16 May 2012 Resolved
GG-01 Replace STBD propulsion shaft. 46 CFR 182.200 Note: On voyage from Multnomah Yacht Yard to home berth note speed limitations resulting from bent shaft and report to H. O'Sullivan/USCG. [phone withheld]
Action required: 705 - Other - as specified
Due 26 May 2012
Resolved 31 August 2012
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 20 December 2011 Resolved
RG01. Provide proof of valid operator's license for all operators to marine inspector. (02 operatros total)
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received all documentation by mail.
Documentation › Certificates/Documents › FCC SSL
Issued 20 December 2011 Resolved
RG03. Provide proof of valid FCC operator license for all operatos to marine inspector. (3 total) 47CFR13
Due 20 January 2012
Resolved 24 January 2012
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 2 August 2011 Resolved
RG01. Provide proof of valid operator's license for all operators to marine inspector. (3 operatros total)
Due 2 September 2011
Resolved 2 December 2011
Resolution: Received a copy of of operator''s license by mail.
Documentation › Certificates/Documents › FCC SSL
Issued 2 August 2011 Resolved
RG03. Provide proof of valid FCC operator license for all operatos to marine inspector. (3 total) 47CFR13
Due 2 September 2011
Resolved 2 December 2011
Resolution: Received a copy of the FCC operator license via email.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 December 2009 Resolved
Identify cause of vibration on the Port shaft & propeller, make repairs prior to returning vessel to service. All repairs are to be made to the satisfaction of attending CG marine inspector.
Action required: 705 - Other - as specified
Due 7 January 2010
Resolved 11 December 2009
Resolution: Identified and renewed sheared engine mount bolt.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 July 2008 Resolved
Fix leaking packing gland on main fuel supply valve located in the steering compartment. Also, remove excess fuel from the bilge. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2008
Resolved 22 January 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 24 July 2008 Resolved
Provide safety covers on overhead light fixtures in fwd accomodation space. 46 CFR 183.410
Condition: Improper Installation
Due 24 August 2008
Resolved 22 January 2009
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 July 2008 Resolved
Provide replacement cover on electrical outlet located above A/C generator in the engine compartment. 46 CFR 183.210
Condition: Improper/Lack of Maintenance
Due 24 August 2008
Resolved 22 January 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 July 2008 Resolved
Replace one adult size CG approved Type I PFD to bring total on board count to 17. Vessel is limited to NMT 16 persons until completed. 46 CFR 180.71
Condition: Unknown
Due 24 August 2008
Resolved 22 January 2009
Operations/Management › Drills/Instruction › Fire
Issued 24 July 2008 Resolved
Provide Anchorage Launch Service Co. written policy outlining how often man-overboard and fire drills are to be carried out on all boats and how drills are to be documented. 46 CFR 185.520
Condition: Unknown
Due 24 August 2008
Resolved 22 January 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 24 July 2008 Resolved
Provide proof of FCC Radiotelephony Certificate renewal. 47 CFR 80
Condition: Improper/Lack of Maintenance
Due 24 August 2008
Resolved 22 January 2009
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 5 April 2007 Resolved
Provide FCC Operators permit for each Master.
Due 5 May 2007
Resolved 4 May 2007
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 April 2007 Resolved
Inventory and update first aid kit.
Due 5 May 2007
Resolved 4 May 2007
Resolution: Corrected
Lifesaving › Rescue Boat › Boarding Ladder
Issued 5 April 2007 Resolved
Add rung below rescue platform to facilitate man overboard retrieval.
Due 5 May 2007
Resolved 4 May 2007
Resolution: Corrected
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 5 April 2007 Resolved
Make permanent repairs to rescue platform bracket fracture.
Due 5 May 2007
Resolved 4 May 2007
Resolution: Corrected
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 July 2006 Resolved
Remove all diesel from bilge of steering compartment. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Due 26 August 2006
Resolved 5 April 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 26 July 2006 Resolved
Install proper metal hangers on all electrical cable runs (and hoses) installed in over head in all compartments. 46 CFR 183.340
Condition: Improper Installation
Due 26 August 2006
Resolved 5 April 2007
Engineering › Fuel Oil Service System › Filter
Issued 26 July 2006 Resolved
Replace all pet cock drains on the 3 Racor fuel filters with either (1) a solid body valve with cap, or (2) a solid metal plug. Note, main engine filter bowls were found nearly fuilled with accumulated water. 46 CFR 182.455(a)(9)
Condition: Improper Installation
Due 26 August 2006
Resolved 5 April 2007
Electrical › Electric Generation Source (service) › Generator
Issued 26 July 2006 Resolved
Prove properly operation and installation of the new Koehler A/C generator. 46 CFR 183.320
Due 26 August 2006
Resolved 5 April 2007
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 26 July 2006 Resolved
Provide a copy of the service/inspection report for both props (were not available at time of drydock inspection). 46 CFR 176.610
Due 26 August 2006
Resolved 20 January 2007
Resolution: Received report from [name withheld]
Engineering › Bilge Water Management System › Pump
Issued 16 June 2005 Resolved
Prove that the bilge pump operates at the required ouput of 10 gallons per minute. 46 CFR 182.25-10
Due 23 June 2005
Resolved 24 June 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 16 June 2005 Resolved
Renew the Emergency Broadcast Placard. 46 CFR 184.506
Due 23 June 2005
Resolved 24 June 2005
Documentation › Certificates/Documents › Stability Letter
Issued 16 June 2005 Resolved
Provide and post stability letter. 46 CFR 176.306
Due 23 June 2005
Resolved 24 June 2005
Stability › Incline Test › General
Issued 3 August 2004 Resolved
Provide and post stability letter. 46 CFR 176.306
Due 3 September 2004
Resolved 16 August 2004
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 August 2004 Resolved
Provide one additional type I PFD. Total persons allowed is reduced to 16 until this item is completed. 46 CFR 180.71
Due 3 September 2004
Resolved 9 August 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 August 2004 Resolved
Renew ring buoy water light battery. This item must be completed prior to operation at night.
Due 3 September 2004
Resolved 9 August 2004
Documentation › Logs/Records › Drug Test Records
Issued 3 August 2004 Resolved
Prove random drug testing has been implemented IAW 46 CFR part 16.
Due 3 September 2004
Resolved 9 August 2004
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 August 2004 Resolved
Provide current light list. 46 CFR 184.420
Due 3 September 2004
Resolved 9 August 2004
Electrical › Lighting (service) › Grounding Conductor
Issued 3 August 2004 Resolved
Remove ungrounded toaster from vessel. 46 CFR 183.370(b)
Due 3 September 2004
Resolved 9 August 2004
Construction/Loadline › Hull › Hull Plating
Issued 3 August 2004 Resolved
Dry bilges in center compartment and make available for CG inspection. 46 CFR 176.404
Due 10 August 2004
Resolved 9 August 2004
Documentation › Certificates/Documents
Issued 7 May 2003 Resolved
Provide valid Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper/Lack of Maintenance
Due 7 June 2003
Resolved 18 June 2003
Documentation › Certificates/Documents › Stability Letter
Issued 7 May 2003 Resolved
Provide valid stability letter.
Condition: Unknown
Due 7 June 2003
Resolved 3 August 2004
Resolution: Reissued requirement under act. 2114331
Documentation › Certificates/Documents
Issued 7 May 2003 Resolved
Provide valid FCC Safety Radiotelephony Certificate. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Due 7 June 2003
Resolved 18 June 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 May 2003 Resolved
Provide one additional adult Type I PFD. Total persons allowed is reduced to 16 until this item is completed. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 7 June 2003
Resolved 18 June 2003
Communications › Alarms/Indicators
Issued 17 April 2002 Resolved
Provide visual auto bilge alarm indicator light for the engine room. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Placed in Improper Service
Due 17 May 2002
Resolved 18 October 2002
Documentation › Manuals/Policy Documentation
Issued 17 April 2002 Resolved
Provide emergency instructions list for area of operation and crew procedures. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Placed in Improper Service
Due 17 May 2002
Resolved 18 October 2002
Lifesaving › Lifebuoys
Issued 17 April 2002 Resolved
Provide new lanyard and throw line for ring buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 17 May 2002
Resolved 17 April 2002
Operations/Management › Passenger Operations
Issued 17 April 2002 Resolved
Provide/make available on shore a passenger count to meet the requirements of 46CFR185.504. LEGACY COMPONENT DESC: Count
Condition: Placed in Improper Service
Due 17 May 2002
Resolved 22 May 2003
Accommodation/Occupational Safety
Issued 17 April 2002 Resolved
Label emergency escape in forward accommodation space, to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Placed in Improper Service
Due 17 May 2002
Resolved 17 April 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 17 April 2002 Resolved
Provide plans for replacement or modifications to all fuel and oil hoses in engineroom. Hoses must meet SAE J 1942 specs, and have SAE J1475 fittings. LEGACY COMPONENT DESC: Fuel/oil hoses
Condition: Placed in Improper Service
Due 17 May 2002
Resolved 23 April 2003
Engineering
Issued 1 May 2000 Resolved
Make proper repairs to lagging on exhaust for both port and stbd engines.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Engineering
Issued 1 May 2000 Resolved
Install marine grade fuel filters in accordance with 46 CFR 182.455.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Lifesaving
Issued 1 May 2000 Resolved
Replace all expired material inside first aid kit.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 3 May 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN LAZARETTE AND IN VOID NUMBER 2.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Documentation
Issued 3 May 1999 Resolved
PROVIDE COPY OF NEW DOCUMENT SHOWING CORRECT OWNER ADDRESS.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Accommodation/Occupational Safety
Issued 3 May 1999 Resolved
MAKE REPAIRS TO PORT FWD ACCOMMODATION SPACE WINDOW.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Documentation
Issued 3 May 1999 Resolved
PROVIDE PROOF OF ENROLLEMENT IN A DRUG TESTING PROGRAM AND PROVIDE COPY OF MIS ANNUAL REPORT.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Construction/Loadline
Issued 3 May 1999 Resolved
MAKE REPAIRS TO FRACTURE IN AFT BULKHEAD STARBOARD SIDE JUST BELOW EXHAUST PIPE IN THE LAZARETTE.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Engineering
Issued 28 May 1997 Resolved
REPLACE ONE 1 INCH GATE VALVE FOR THE PORT ENGINE EXHAUST COOLING.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Electrical
Issued 28 May 1997 Resolved
INSURE BATTERY BOXES ARE LIQUID TIGHT AND INSTALL WOOD BLOCKS TO PREVENT BATTERY MOVEMENT.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Construction/Loadline
Issued 28 May 1997 Resolved
REPAIR CRACK IN ENGINE MOUNT FRAME ON STARBOARD SIDE CENTER MOUNT.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Construction/Loadline
Issued 5 May 1997 Resolved
REPAIR THE FRACTURED WELDS LOCATED IN THE LAZARETTE AFT BULKHEAD AT DECKLINE BETWEEN THE TWO VERTICAL STIFFENERS.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 5 May 1997 Resolved
PROVE PROPER OPERATION OF THE PORT AND STARBOARD BILGE PUMPS.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 5 May 1997 Resolved
PROVIDE CHECK VALVES AT THE BILGE MANIFOLD OR IN THE PIPING SYSTEM IN EACH COMPARTMENT.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 5 May 1997 Resolved
PROVIDE A CG APPROVED FIRST AID KIT OR EQUIVALENT.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Electrical
Issued 5 May 1997 Resolved
REMOVE THE WIRE NUTS IN THE ENGINE COMPARTMENT AND UNDER THE STEERING CONSOLE AND REPLACE WITH PRESSURE TYPE CONNECTORS.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 20 June 1996 Resolved
CONDUCT A SATISFACTORY MAN OVERBOARD DRILL IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Documentation
Issued 28 May 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Fire Fighting
Issued 28 May 1996 Resolved
COMPLETE HYDRO TEST ON B-II DRY CHEM EXTINGUISHER WITH 1983 DATE OF MANUFACTURE. COMPLETE 6-YEAR MAINTENANCE ON B-II DRY CHEM EXTINGUISHER WITH 1990 DATE OF MANUFACTURE.
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 28 May 1996 Resolved
PROVIDE FOUR ADDITIONAL ADULT PFD'S TO BRING TOTAL NUMBER TO 17. VESSEL ISLIMITED TO THE CARRIAGE OF 11 ADULT PASSENGERS UNTIL COMPLETION.
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 2 June 1995 Resolved
PROVIDE DOCUMENTARY EVIDENCE OF POSTING OF PFD DONNING INSTRUCTION PLACARD.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Electrical
Issued 2 June 1995 Resolved
PROVIDE PHOTOGRAPHIC EVIDENCE OF INSTALLATION OF BLANK COVERS FOR 110V RECEPTACLE BREAKER PANEL IN E/R.
Condition: Unknown
Due 9 June 1995
Resolved 8 June 1995
Documentation
Issued 2 June 1995 Resolved
PROVIDE DOCUMENTARY EVIDENCE OF CURRENT CREW DRUG TESTING PARTICIPATION.
Condition: Unknown
Due 7 June 1995
Resolved 8 June 1995
Engineering
Issued 29 June 1992 Resolved
REPLACE WORN STBD RUBBER CUTLASS BEARING.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992

Casualty record · 8

23 May 2004Routine · role: Involved in a Marine Casualty · activity 2235728
3 January 2009Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3391590
15 January 2009Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3397934
26 July 2010Routine · role: Involved in a Marine Casualty · activity 3808190
13 May 2012Routine · role: Involved in a Marine Casualty · activity 4311541
1 September 2012Routine · role: Involved in a Marine Casualty · activity 4440037
27 September 2021Routine · role: Involved in a Marine Casualty · activity 7331466
15 December 2025Routine · role: Involved in a Marine Casualty · activity 8291699
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.