Records from 2000 to 2019. Most recent: inspection, 14 November 2019.
Inspection history · 48
14 November 2019
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6853637
15 April 2019
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6660649
5 April 2019
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6651061
3 April 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6655248
21 December 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6601324
21 December 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6601595
10 December 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6595255
9 December 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6594245
9 December 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6594314
24 September 2018
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6545833
11 September 2017
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6264035
14 May 2017
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6145914
25 February 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6094617
4 October 2016
COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6011370
28 August 2016
Ballast Water Examination · Administrative Inspection · COC-TVE Renew · ISPS III Exam · COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5979781
25 February 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5821805
24 February 2016
Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5818491
24 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5820608
23 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5857475
30 November 2015
PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5771960
6 October 2015
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5736897
15 July 2015
COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5178145
14 May 2012
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4311318
13 May 2012
COE-Offshore · ISPS I Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4309819
27 January 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3934097
10 March 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3430950
5 March 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3428194
26 August 2008
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3309380
13 August 2008
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3297186
20 September 2007
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3061916
20 September 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3062343
17 July 2007
ISPS II Exam · COC-TVE Renew · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2997883
12 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2886504
11 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2885715
6 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2864118
14 July 2006
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2709452
2 May 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2638586
8 July 2005
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · COC-TVE Renew · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2419414
22 February 2005
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2296725
25 January 2005
NPV Safety Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2280702
8 December 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2255696
6 July 2004
COC-TVE Annual · ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2123163
10 February 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2004111
24 November 2003
Special Interest Vessel
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1953666
9 June 2003
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1813790
19 January 2002
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1479585
22 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 275834
22 March 2000
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 816387
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2019
Resolved
13199- Other (machinery)- The machinery and associated piping and fittings shall be of a desing and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce minimum any danger to persons on board. PSCO observed fuel oil leaks on the #2 and #4 M/E cylinders. 74 SOLAS (2002 cons.) II-1/26.1 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2019
Resolution: Received, reviewed and accepted class report from LR stating the fuel pumps were overhauled and operated without visual leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2019
Resolved
13199- Other (machinery)- The machinery and associated piping and fittings shall be of a desing and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce minimum any danger to persons on board. PSCO observed active fuel oil drips/leaks coming from multiple cylinders on all three auxiliary engines. 74 SOLAS (2002 cons.) II-1/26.1 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2019
Resolved 6 April 2019
Resolution: Received, reviewed and accepted class report from LR stating the O rings throughout the fuel injection piping was renewed on multiple cylinders and all 4 A/E were testing with sat results.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 July 2007
Resolved
Soft patch (fiberglass wrap) found on sea-water cooling overboard pipe for main engine, lower level engine room. Make repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 20 September 2007
Resolution: Received Class Report testifying to the repairs being completed.
Documentation
Issued 22 March 2000
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, VESSEL MUST HAVE ON BOARD AN APPROVEDVESSEL RESPONSE PLAN. FAX COVER SHEET OF PLAN TO USCG. RECEIVED FAX ON 22MAR00. DEF CLEARED.
Condition: Unknown
Due 22 March 2000
Resolved 13 April 2000