SFL ALBANY is a tank ship. The Coast Guard has recorded 8 inspections since 2021, most recently in April 2026, along with 3 deficiencies and 1 operational control.
Records from 2021 to 2026. Most recent: inspection, 17 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it81466 - Convention (Subpart B), Gross Ton 158060 - Dead Weight, Ton 182557 - Displacement, Ton 50994 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 December 2024Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO DISCOVERED BROKEN HOUSING FOR AND IMPROPERLY REPAIRED THIRD PHASE (BLACK) ON NO.1 BLOWER MOTOR CIRCUIT. BLOWER IS UNABLE TO PROPERLY READ RPM'S FOR OVERCLOCK CONTROL LOCALLY. CORRECTIVE ACTION TAKEN TO REPAIR POWER CONNECTOR FOR NO.1 BLOWER IS CREATING AN ELECTRICAL HAZARD. CURRENT TRANSFORMER FOR BOTH NO.1 AND NO.2 BLOWERS NOT OPERATIONAL. VESSEL MAY NOT USE NO.1 BLOWER PRIOR TO RECTIFICATION.
74 SOLAS (20) II-1/45.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2024
Resolved 26 February 2025
Resolution: VESSEL REPLACED BOTH CURRENT TRANSFORMERS, TESTED BOTH OVERCURRENT PROTECTIONS, AND PROVIDED PROOF OF RECTIFICATION ALONG WITH MASTERS ATTESTATION OF REPAIRS.
The condition of the ship and its equipment shall be maintained to conform with the provisions of regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed flange between OP-250 and OP-256 valves leaking crude oil cargo. This flange is in line with Cargo Pump #2 at bottom of Cargo Pump Room. Leak has been determined to be from expansion due to temperature and it is estimated to be approximately 0.2 m3 that leaked from flange. OP-250 is a non-return valve and was closed due to cargo operations being secured prior to PSCO attendance. Vessel is restricted from using Cargo Pump #2 for cargo operations.
SOLAS 74(20) I/11(a) 17a,c
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2023
Resolved 12 June 2023
Resolution: Vessel provided class report attesting to the retification of the deficiency to the satsifaction of class and CG.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 September 2022Resolved
EACH VESSEL VAPOR CONNECTION FLANGE FACE MUST HAVFE A PERMANENT STUD PROJECTING OUTWARD THAT HAS A 12.7 MILLIMETER (0.5 INCH) DIAMETER AND IS AT LEAST 25.4 MILLIMETERS (1 INCH) LONG. VESSEL REMOVED THE VAPOR STUD ON THE PORT FORWARD MANIFOLD TO MAKE FULL CONTACT WITH THE FACILITY FLANGE. STUD MUST BE REATTACHED BY PERMANENT MEANS
46 CFR 39.2001(j)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2023
Resolution: 30MAY2023: Received photos and proper documentation from vessel stating all outstanding deficiencies have been rectified. Photos are attached.