GRAND TOWER is a 2001 towing vessel. The Coast Guard has recorded 6 inspections since 2022, most recently in May 2026, along with 13 deficiencies.

Records from 2022 to 2026. Most recent: inspection, 19 May 2026.

Built
2001
Last inspected
19 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 19 May 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2022–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1673856
Flag
UNITED STATES
Maury page id
psix-1673856

Documentation record

Tonnage as PSIX records it89 - Simplified, Net Ton
111 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

19 May 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8373245
12 November 2025 In-Service Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8267522
8 May 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8130808
5 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8121602
12 December 2023 COI Inspection · Administrative Inspection · Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7838186
15 March 2022 Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412904

Deficiency record · 13

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 November 2025 Resolved
Machinery must be designed and maintained to provide for safe operation of the vessel under normal and emergency conditions. It was reported that one of the generators lost power which caused a momentary loss of power throughout the vessel. Prove proper operation prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 November 2025
Resolution: 835 cleared
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 May 2025 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The high bilge audible alarm was inoperable in the pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 8 May 2025
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 12 December 2023 Resolved
46 CFR 143.235 (b)(3) Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station”; No signage next to the general alarm flashing light in the engine room.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI completed def check on item, all sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 December 2023 Resolved
46 CFR 143.260 Fuel shutoff required to stop the flow of fuel in the event of a fire or break in the fuel line. must be operable from a safe place outside the space where the valve is installed; must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. 1. Fuel shut off valves labels were not 1 inch in height 2. Tool to operate shut off valve needs to be in the vicinity of the valves.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI completed def check on item, all sat.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 12 December 2023 Resolved
46 CFR 136.212 The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. Fire drill, Man over board, abandon ship drill to be completed in presence of a marine inspector prior to the issuance of a COI.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attneding MI conducted MOB and Fire Drills, All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 December 2023 Resolved
46 CFR 142.330 (a)(7) The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience, to comply with paragraphs (a)(1) through (6) of this section. 1. installed fire detection system and panel design and installation hasn't been approved by a PE. 2. When 12 Volt backup supply is disconnected, no alarm 3. Galley Sensor does not activate system. The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Quick-acting water tight door in FWD storage room is not water-tight.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI completed def check on item, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 December 2023 Resolved
46 CFR 140.610 (b) The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Quick-acting water tight door in FWD storage room is not water-tight.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI witnessed proper operation of QAWTD.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 December 2023 Resolved
46 CFR 140.605 (a) The vessel's operation or a history of satisfactory service does not cause the stability of the vessel to be questioned by either the Coast Guard or a TPO engaged to perform an audit or survey. 1. There is no letter attesting to the vessels stability.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI completed def check on item, all sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 12 December 2023 Resolved
46 CFR 143.230 (a)(5) Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (5)Click to open paragraph tools High bilge levels High level bilge alarm for forward starboard void – visual light does not operate.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI witnessed proper operation of fwd stbd void bilge alarm, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 December 2023 Resolved
46 CFR 143.400(a) Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. 1. Electronics room has exposed dead end wire(s)
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI completed def check on item, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 December 2023 Resolved
46 CFR 140.435 Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. 1. First aid kit at operator’s station contains expired items
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI completed def check on item, all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 12 December 2023 Resolved
33 CFR 164.72 Each VHF radio operator must hold a restricted operator's license or higher. 1. Army issued radio station license not available for inspection.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI completed def check on item, all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 December 2023 Resolved
46 CFR 142.240 Fixed fire-extinguishing system maintenance receipts and other records generated by these inspections and tests must be retained for at least 1 year and made available upon request. 1. unable to provide fixed fire-extinguishing annual maintenance and testing records.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI completed def check on item, all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.