← All vessels
PATHFINDER
PATHFINDER is a 1995 towing vessel. The Coast Guard has recorded 5 inspections since 2022, most recently in May 2026, along with 32 deficiencies.
Records from 2022 to 2026. Most recent: inspection, 20 May 2026.
- Built
- 1995
- Last inspected
- 20 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 32 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
AEBQ
1673857
Flag
UNITED STATES
—
Maury page id
psix-1673857
Inspections, by type
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it103 - Simplified, Net Ton
103 - Simplified, Gross Ton
103 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 5
20 May 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8373231
5 May 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8121595
19 August 2024
Excursion Permit · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7984634
25 September 2023
Initial Certification · COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7834095
15 March 2022
Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412912
Deficiency record · 32
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 May 2025
Resolved
Each towing vessel must have a fire detection system installed to detect engine room fires. The heat sensing probe in the lower ER wasn't working during testing. Prove proper operation prior to movement
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2025
Resolved
Pressure vessels must be equipped with one or more spring loaded relief valves. Repair existing relief valve and place new relief valves on each bottle within 30 days.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 May 2025
Resolved
Each watertight door must be marked on both sides "WATERTIGHT DOOR-KEEP CLOSED" Mark both sides of the watertight door within 30 days.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 5 December 2023
Resolved
46 CFR 144.905(b)
Means must be provided to ensure that windows immediately forward of the operating station in the pilothouse allow for adequate visibility to ensure safe navigation regardless of weather conditions. Inoperable FWD center windshield wiper.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 5 December 2023
Resolved
46 CFR 140.410(b)/ 46 CFR140.645
Prior to getting underway for the first time on a particular towing vessel, each crew member must receive a safety orientation.
Unable to provide documentation that Safety Orientation for all crew and navigational training.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 5 December 2023
Resolved
46 CFR 142.245/ 46 CFR 140.420
The master of a towing vessel must ensure that each crew member participates in fire-fighting drills and receives instruction at least once each month, and ensure proper record keeping
Crew not conducting monthly fire-fighting drills.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 December 2023
Resolved
46 CFR 143.245
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section.
No record of general alarm, pressure vessel relief valves, alarm set points, and other essential systems (such as emergency fuel shut downs).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2023
Resolved
46 CFR 142.240
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section, or more frequently if otherwise required by the TSMS applicable to the vessel.
Fire Detection system hasn't been serviced in the past 12 months.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2023
Resolved
46 CFR 142.230(b)
Towing vessels of more than 65 feet in length must carry the proper amount of portable fire extinguishers. Vessel is required to carry (2) 40-B portable fire extinguishers in the engine room, and (3) 40-B:C Throughout the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2023
Resolved
46 CFR 143.300
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves.
Pressure relief valves need to be installed on each tank to ensure MAWP is not exceed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 December 2023
Resolved
46 CFR 143.235 (b)(2)
Each towing vessel must be fitted with a general alarm that: (2) Is capable of notifying persons in any accommodation, work space, and the engine room.
Alarms above fridge in galley were obstructed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 August 2022
Resolved
Vessel must be equipped with a fixed firefighting system FFS (if not equipped with semi-portable 160-B extinguisher). IAW 46 CFR 136.110 FFS required to be approved by Commandant; Approval based on Installation IAW USCG approved manufacture's manual. FFS missing 2nd control (stop) valve as required for systems with more than 300 lbs of CO2.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 August 2022
Resolved
FFS must be serviced every 12 months. Record not available showing FFS had been serviced w/in last 12 mo.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 August 2022
Resolved
FFS must be tested as required by 46 CFR 147.60; Cylinders required to be tested every 12 years. Last test date stamped on cylinders head was in 2008.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 August 2022
Resolved
A vessel must be operated in such a manner as to afford protection against hazards to life, property, and the environment. Fire alarm horn/strobe (high decibel audio & visual strobe light) located at operating station has potential to significantly distract master's ability to operate vessel in a safe manner during an emergency.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 August 2022
Resolved
Fuel shutoff required to stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator or prime mover; must be installed in the fuel piping directly outside of the fuel oil supply tank; must be operable from a safe place outside the space where the valve is installed; must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. The vessel's remote fuel shut off:
a. Location of remote operation for forward fuel tank inaccessible.
b. Inboard fuel supply line; remotely operated valve has disconnected reach rod.
c. No remotely operated valve for aft fuel tank.
d. Location of remote operation for forward fuel tank not labeled with purpose of operating instructions.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 10 August 2022
Resolved
Engine Alarm set points required to be tested. Not tested. Test in the presences of a marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 August 2022
Resolved
Closure devices for hull penetrations. Exterior deck hatches (all) wasted compromising watertight integrity.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 August 2022
Resolved
Radio station license (U.S. Army issued) not on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 10 August 2022
Resolved
Each VHF radio operator must hold a restricted operator's license or higher. Operator not licensed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 August 2022
Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry and maintain for ready reference, a copy of these Rules. Copy not on board.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 August 2022
Resolved
A vessel must be operated in such a manner as to afford protection against hazards to life, property, and the environment. Bilge alarm for sensor located in forward peak STBD, void #1 Port, and aft center (steering room) were inoperable.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 August 2022
Resolved
Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS”. Container not labeled as required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 August 2022
Resolved
For towing vessels with berthing aboard, a sufficient number of additional lifejackets must be carried so that a lifejacket is immediately available for persons at each normally manned watch station. There was no lifejacktet at the operator's station.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 August 2022
Resolved
Each towing vessel must be operated in compliance with 33 CFR 155 & 156 (Prevention of oil pollution). Vessel does not have oil transfer procedures, equipment not tested, and Declaration of Inspections not incorporated.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 August 2022
Resolved
A vessel must be operated in such a manner as to afford protection against hazards to life, property, and the environment. First aid kit contained expired items.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2022
Resolved
All portable fire extinguishers must be approved by the Commandant (CG-ENG) Approval includes use of a suitable bracket (46 CFR 162.028-3). Engine Room extinguishers were not in approved brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 August 2022
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge. Forward pressure vessel's gauge not suitable for application.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 August 2022
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Second deck aft corner not equipped with protection.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 August 2022
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail.
a. Generator engines pulleys not protected.
b. Steering rudder arms/connector bar not protected.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 August 2022
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room vent louvers missing connecting rod(s).
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 10 August 2022
Resolved
The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. Fire drill, Man over board, abandon ship drill to be completed in presence of a marine inspector prior to the issuance of a COI.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.