MAURY USCG vessel records
← All vessels

PATHFINDER

PATHFINDER is a 1995 towing vessel. The Coast Guard has recorded 5 inspections since 2022, most recently in May 2026, along with 32 deficiencies.

Records from 2022 to 2026. Most recent: inspection, 20 May 2026.

Built
1995
Last inspected
20 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 20 May 2026
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2022–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1673857
Flag
UNITED STATES
Maury page id
psix-1673857

Documentation record

Tonnage as PSIX records it103 - Simplified, Net Ton
103 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 5

20 May 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8373231
5 May 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8121595
19 August 2024 Excursion Permit · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7984634
25 September 2023 Initial Certification · COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7834095
15 March 2022 Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412912

Deficiency record · 32

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 May 2025 Resolved
Each towing vessel must have a fire detection system installed to detect engine room fires. The heat sensing probe in the lower ER wasn't working during testing. Prove proper operation prior to movement
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2025 Resolved
Pressure vessels must be equipped with one or more spring loaded relief valves. Repair existing relief valve and place new relief valves on each bottle within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2025
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 May 2025 Resolved
Each watertight door must be marked on both sides "WATERTIGHT DOOR-KEEP CLOSED" Mark both sides of the watertight door within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 5 December 2023 Resolved
46 CFR 144.905(b) Means must be provided to ensure that windows immediately forward of the operating station in the pilothouse allow for adequate visibility to ensure safe navigation regardless of weather conditions. Inoperable FWD center windshield wiper.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI witnessed proper operation of wiper.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 5 December 2023 Resolved
46 CFR 140.410(b)/ 46 CFR140.645 Prior to getting underway for the first time on a particular towing vessel, each crew member must receive a safety orientation. Unable to provide documentation that Safety Orientation for all crew and navigational training.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI reviewed proper documentation, all sat.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 5 December 2023 Resolved
46 CFR 142.245/ 46 CFR 140.420 The master of a towing vessel must ensure that each crew member participates in fire-fighting drills and receives instruction at least once each month, and ensure proper record keeping Crew not conducting monthly fire-fighting drills.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI reviewed proper documentation, all sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 December 2023 Resolved
46 CFR 143.245 Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. No record of general alarm, pressure vessel relief valves, alarm set points, and other essential systems (such as emergency fuel shut downs).
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI reviewed proper documentation, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2023 Resolved
46 CFR 142.240 All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section, or more frequently if otherwise required by the TSMS applicable to the vessel. Fire Detection system hasn't been serviced in the past 12 months.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI reviewed proper documentation, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2023 Resolved
46 CFR 142.230(b) Towing vessels of more than 65 feet in length must carry the proper amount of portable fire extinguishers. Vessel is required to carry (2) 40-B portable fire extinguishers in the engine room, and (3) 40-B:C Throughout the vessel.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI verified fire extinguishers, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2023 Resolved
46 CFR 143.300 Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. Pressure relief valves need to be installed on each tank to ensure MAWP is not exceed.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI reviewed installation of relief valves, all sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 December 2023 Resolved
46 CFR 143.235 (b)(2) Each towing vessel must be fitted with a general alarm that: (2) Is capable of notifying persons in any accommodation, work space, and the engine room. Alarms above fridge in galley were obstructed.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Attending MI observed unobstructed alarm above fridge.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 August 2022 Resolved
Vessel must be equipped with a fixed firefighting system FFS (if not equipped with semi-portable 160-B extinguisher). IAW 46 CFR 136.110 FFS required to be approved by Commandant; Approval based on Installation IAW USCG approved manufacture's manual. FFS missing 2nd control (stop) valve as required for systems with more than 300 lbs of CO2.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: MI conducted initial Certificate of Inspection, All sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 August 2022 Resolved
FFS must be serviced every 12 months. Record not available showing FFS had been serviced w/in last 12 mo.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: MI conducted initial Certificate of Inspection, All sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 August 2022 Resolved
FFS must be tested as required by 46 CFR 147.60; Cylinders required to be tested every 12 years. Last test date stamped on cylinders head was in 2008.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: MI conducted initial Certificate of Inspection, All sat.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 August 2022 Resolved
A vessel must be operated in such a manner as to afford protection against hazards to life, property, and the environment. Fire alarm horn/strobe (high decibel audio & visual strobe light) located at operating station has potential to significantly distract master's ability to operate vessel in a safe manner during an emergency.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Crew disconnected fire alarm enuciator in pilot house. Fire alarm panel still functioning properly.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 August 2022 Resolved
Fuel shutoff required to stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator or prime mover; must be installed in the fuel piping directly outside of the fuel oil supply tank; must be operable from a safe place outside the space where the valve is installed; must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. The vessel's remote fuel shut off: a. Location of remote operation for forward fuel tank inaccessible. b. Inboard fuel supply line; remotely operated valve has disconnected reach rod. c. No remotely operated valve for aft fuel tank. d. Location of remote operation for forward fuel tank not labeled with purpose of operating instructions.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: MI conducted initial Certificate of Inspection, All sat.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 10 August 2022 Resolved
Engine Alarm set points required to be tested. Not tested. Test in the presences of a marine inspector.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Tested engine alarm set points, All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 August 2022 Resolved
Closure devices for hull penetrations. Exterior deck hatches (all) wasted compromising watertight integrity.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Replaced all exterior deck hatches, watertight test SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 August 2022 Resolved
Radio station license (U.S. Army issued) not on board.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Radio station license on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 10 August 2022 Resolved
Each VHF radio operator must hold a restricted operator's license or higher. Operator not licensed.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: MI conducted initial Certificate of Inspection, All sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 August 2022 Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry and maintain for ready reference, a copy of these Rules. Copy not on board.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Copy on board.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 August 2022 Resolved
A vessel must be operated in such a manner as to afford protection against hazards to life, property, and the environment. Bilge alarm for sensor located in forward peak STBD, void #1 Port, and aft center (steering room) were inoperable.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: MI conducted initial Certificate of Inspection, All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 August 2022 Resolved
Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS”. Container not labeled as required.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Pyro in proper watertight container.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 August 2022 Resolved
For towing vessels with berthing aboard, a sufficient number of additional lifejackets must be carried so that a lifejacket is immediately available for persons at each normally manned watch station. There was no lifejacktet at the operator's station.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Lifejacket is now at the operator's station
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 August 2022 Resolved
Each towing vessel must be operated in compliance with 33 CFR 155 & 156 (Prevention of oil pollution). Vessel does not have oil transfer procedures, equipment not tested, and Declaration of Inspections not incorporated.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Vessel is now in complaince.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 August 2022 Resolved
A vessel must be operated in such a manner as to afford protection against hazards to life, property, and the environment. First aid kit contained expired items.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: New first aid kit on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2022 Resolved
All portable fire extinguishers must be approved by the Commandant (CG-ENG) Approval includes use of a suitable bracket (46 CFR 162.028-3). Engine Room extinguishers were not in approved brackets.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Fire extinguishers in proper brackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 August 2022 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge. Forward pressure vessel's gauge not suitable for application.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Pressure vessels had gauges installed on them.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 August 2022 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Second deck aft corner not equipped with protection.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Safety chains in place.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 August 2022 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. a. Generator engines pulleys not protected. b. Steering rudder arms/connector bar not protected.
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Guards are in place.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 August 2022 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room vent louvers missing connecting rod(s).
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Witness proper operation of vent louvers.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 10 August 2022 Resolved
The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. Fire drill, Man over board, abandon ship drill to be completed in presence of a marine inspector prior to the issuance of a COI.
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Conducted MOB Drill, All SAT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.