MAURY USCG vessel records Sign in
← All vessels

BOX ENDURANCE

BOX ENDURANCE is a freight ship. The Coast Guard has recorded 15 inspections since 2021, most recently in April 2026, along with 4 deficiencies and 8 operational controls.

Records from 2021 to 2026. Most recent: inspection, 8 April 2026.

Built
Not recorded
Last inspected
8 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9733820 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1676392
Flag
LIBERIA
—
Maury page id
psix-1676392

Inspections, by type

…with no type recorded8
Years with a record 4 calendar years (2021–2026)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it17907 - Convention (Subpart B), Gross Ton
21718 - Dead Weight, Ton
29904 - Displacement, Ton
8103 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

8 April 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8344566
5 December 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8043523
29 November 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8041252
28 November 2024 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8040993
25 November 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8039857
20 October 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8021765
12 September 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8001150
11 September 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8000618
25 March 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7884776
11 February 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7863913
6 February 2024 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7861594
8 October 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7805158
7 October 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7804807
3 October 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7802358
9 September 2021 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7298251

Deficiency record · 4

09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 8 April 2026 Resolved
The machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The design shall have regard to the working conditions to which it will be subject and the environmental conditions on board. A saltwater cooling pipe located on the second deck of the engine rool starboard side appears damages and is leaking saltwater in the vacinity of heat exchanger. 74SOLAS(24) II-1/26.1 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 May 2026
Resolution: Class report attesting to repairs to the pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 September 2024 Resolved
Boilers shall have suitable means to preclude, as far as practicable, the entry of oil which may affect the boiler. PSCO found 1 inch of oil in the cascade tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 20 October 2024
Resolution: Sector Miami received survey report attesting def.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 8 February 2024 Resolved
All ships of 3,000 gross tons and upwards shall, in addition to meeting the requirements of paragraph 2.5, have: A 3 GHz radar or, where considered appropriate by the administration, a second 9 GHz radar. PSCO was advised by the Vessel's master that the 3 GHz, S-Band Radar, is inoperable. 74S0LAS(20)v/19.2.7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 March 2024
Resolution: Technician replaced radar with new unit.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 October 2023 Resolved
3 GHZ S-BAND RADAR INOP BEYOND 6NM
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 8 November 2023
Resolution: S-band radar fully operational, technician repairs satisfactory

Ownership record