Records from 2021 to 2026. Most recent: inspection, 5 February 2026.
Inspection history · 17
5 February 2026
COC-CHEM & TVE Renew · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8305141
11 November 2025
COE-Administrative · Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8267002
13 August 2025
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8214290
4 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8201997
10 April 2025
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8109739
15 November 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8033179
29 October 2024
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8026199
19 July 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7961837
7 April 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7891194
14 December 2023
COC-CHEM & TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7837530
8 December 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7836731
29 January 2023
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7628592
8 September 2022
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7553487
10 June 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7473767
30 September 2021
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7324206
26 September 2021
PSC A · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7317151
25 September 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7320152
14 - Pollution Prevention › 148 - Ballast Water › Alternative Management Method
Issued 10 June 2022
Resolved
To discharge ballast water into waters of the United States, the master, owner, operator, agent, or person in charge of a vessel subject to § 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standard as defined in § 151.2030(a), use an AMS as described in § 151.2025(a)(3) or ballast exclusively with water from a U.S. public water system, as described in § 151.2025(a)(2), according to the schedule in paragraph (b) of this section.
Subject vessel, of keel laid date 21Jan14 and ballast water capacity of 20,051 m3, is past its compliance date per the implementation schedule in 33 cfr 151.2035(b). Currently, vessel's installed BWTS is inoperative
Vessel is NOT authorized to discharge untreated ballast into the waters of the US without prior written authorization from the local COTP under the provisions of 33CFR151.2040 (b)
33CFR151.2035
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 14 June 2022
Resolved 14 June 2022
Resolution: Received tech report with repairs.