SUPERIOR TRUST is a 1979 offshore supply vessel. The Coast Guard has recorded 18 inspections since 2016, most recently in June 2026, along with 50 deficiencies and 1 casualty investigation in 2017.

Records from 2016 to 2026. Most recent: inspection, 4 June 2026.

Built
1979
Last inspected
4 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM9430
167758
Flag
UNITED STATES
Maury page id
psix-167758

Documentation record

Registered dimensions (L × B × D)60.0 ft × 30.0 ft × 6.6 ft
Registered tonnagegross 79 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOASTAL CONSTRUCTION AND SHIPYARD INC · GALLIANO, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it79 - Simplified, Gross Ton
63 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

4 June 2026 Hull Examination · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8394768
24 July 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7966221
8 June 2023 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7709302
29 August 2022 Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7540640
10 May 2022 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7447843
8 May 2022 Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7559593
28 April 2022 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7442335
16 September 2021 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7313800
29 April 2021 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7184874
11 March 2021 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7155213
28 September 2020 Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7072004
20 July 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7011662
30 May 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6704994
8 March 2018 Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6368573
15 February 2017 Damage Survey · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6089955
15 February 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6103671
15 January 2017 Administrative Inspection · Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6220197
16 February 2016 Drydock Exam · Internal Structural Exam · Deficiency Check · COI Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5813355

Deficiency record · 50

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 August 2024 Resolved
Fire Pump shall be 50 gallons per minute at a pressure of not less than 60 PSI at the pump outlet. During fire drill, fire pump was displaying 42 psi. Repair/adjust submersible fire pump to output 60 psi from gauge or nozzle.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 September 2024
Resolution: 62 psi noted. Sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 August 2024 Resolved
Electrical equipment vital to safe navigation will be given special consideration shall be subject to req. from OCMI; Each vessel that relies on electrical power must be arranged so that the loads can be energized from 2 sources of electricity: vital systems, interior lighting, comms systems including PA system, navigation equipment and lights. Vessel did not have back up power for PA system or navigation systems and lights. Vessel shall install back up power for PA system and navigation system and lights that will maintain power for 03 hours after vessel loses ship's power.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2024
Resolution: Backup power installed, sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 August 2024 Resolved
Marine Inspector shall require that all observed unsafe practices and hazardous situation be corrected. Emergency lights shall be in each accommodation space (01 room did not contain an emergency light) and the lights shall be directed towards each exit of the space (port aft room emergency light was not directed toward aft exit). Cite: 46 CFR 176.25-50 OLD T
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2024
Resolution: 02 emergency lights installed, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2024 Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration. Fuel line in machinery space noted to not have chafing gear. Vessel shall install with chafing gear on fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2024
Resolved 3 September 2024
Resolution: Chafing gear installed, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 August 2024 Resolved
Hatches must be made weathertight. Hatch going from accommodation space to engine room was noted to utilize a non marine grade gasket. Vessel shall install a weathertight, marine grade gasket.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2024
Resolved 3 September 2024
Resolution: Weathertight, marine grade material installed, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2024 Resolved
Cable and wires must be installed with metal supports spaced not more than 24 inches apart and in a manner to avoid chafing. Vessel noted to have metal support on one wire for interconnected fire detection but plastic ties for the rest. Wires going throughout the vessel must be install with metal supports (not metal or plastic ties, but supports that are with the overhead, a beam, etc).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2024
Resolved 3 September 2024
Resolution: Cable supports installed, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 August 2024 Resolved
The COI issued to a vessel describes the vessel routes, minimum manning requirements, etc. and any equivalencies accepted or authorized by the OCMI. Vessel went underway/in transit without meeting minimum manning requirements (logged 03 members when in transit when COI states minimum of 04). Vessel shall maintain minimum manning when in transit and any other manning requirements as stated on COI.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 28 August 2024
Resolved 29 August 2024
Resolution: Educated crew on purpose of minimum manning. Special Note create on MISLE.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 July 2024 Resolved
At inspection for certification of a vessel, owner /operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Vessel's engine rooms contained excessive oil on deck and a shaft seal was noticed to be worn out, allowing water intake. Inspection of all machinery spaces and units were halted. All oil, water, known damage to machinery and cause of spill are to be properly packaged, offloaded, cleaned, repaired and made ready for operation and inspection. No operations of machinery will be allowed and vessel is to remained tied to the pier until satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 August 2024
Resolution: Engine room inspection sat.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 25 July 2024 Resolved
Vessel must have an interconnected detection and alarm system. Vessel is to install interconnected fire and smoke detection system and the appropriate type of detection system in specific location as discussed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2024
Resolved 28 August 2024
Resolution: Interconnected fire detection system insatlled and tested, sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 July 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in bilges. No switch is permitted to silence or disable any functions of the high bilge alarms. Switches that have the capability to do so are to be disconnected.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2024
Resolution: Silence switch isolated to only tilt alarm. Bilge Alarm is no longer silenced. Sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 July 2024 Resolved
For intended voyage, vessel must carry adequate and up-to-date charts of large enough scale for safe navigation. Chart corrections must be recorded and performed so all charts to be up-to-date.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2024
Resolved 28 August 2024
Resolution: Log created, sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 July 2024 Resolved
A person may not employ or engage in a position required to hold an MMC unless the individual maintains a current medical card. Licensed mate is to have a valid medical card and TWIC with them while onboard and engaged in operations and inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2024
Resolved 28 August 2024
Resolution: Valid medical card present, sat.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 25 July 2024 Resolved
Crew accommodation and work space must be with suitable equipment for the protection and accommodation of the crew while in modes of operation of the vessel. Directv box was held up by a rubber strap, must be placed in a secured location to prevent injury of crew.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2024
Resolved 28 August 2024
Resolution: Box installed in sat location, sat
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 July 2024 Resolved
Each survival craft equipment must be of good quality and efficient for it purpose. Both lifefloat's plugs were puncture/damage and will need to be repaired/replaced to be in original factory condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2024
Resolution: Life floats replaced, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 July 2024 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use. Retro reflective tapes must be replaced on all lifefloats, rescue boat including an additional strip on the bottom side, and life rings.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2024
Resolution: Retro tape replaced on rescue boat, life float, and life rings, sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2022 Resolved
All electrical installations shall be to the satisfaction of the OCMI; wiring for submersible pump was frayed and spliced without proper covering. Replace submersible pump prior to departure. 46 CFR 183.01-15(a) Old "T"
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2022
Resolution: Pump replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 August 2022 Resolved
Vessels with power-driven fire pump shall also be provided with fire main system; fire main system in deficient condition, pipe leaked when running due to heavy corrosion. Replace piping prior to departure. 46 CFR 181.15-1 Old "T"
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2022
Resolution: Corroded piping cropped and renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 August 2022 Resolved
Scantlings and material of each vessel are to be such as to provide for safe operation; ballast water vent had significant corrosion, compromising watertight integrity of vessel. Renew vent. 46 CFR 177.01-5(a) Old "T"
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2022
Resolution: Cropped and renewed
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 28 April 2022 Resolved
The inspection and maintenance of launching appliances shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel recently changed managing operator and inspection could not determine when workboat's lifting strap was inspected. Lifting strap's condition was questionable with mold and UV damage. If replaced, strap shall have a design safety factor of 6 times maximum working load. 46 CFR 185.702(d), District 8 Policy Ltr 98-13, Rescue Boat Requirements on OSVs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2022
Resolution: New workboat lifting strap was provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 April 2022 Resolved
Each hatch used as a means of escape, must be capable of being opened by one person, from either side. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Engine room escape hatch spring had wasted and broke making hatch more difficult to open from below deck. 46 CFR 177.500(h)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2022
Resolution: Engine room escape hatch was replaced with new.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 28 April 2022 Resolved
A vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material as cargo must have a mechanical means of closing each drain and scupper in the container or enclosed deck area. Vessel's fuel vent containments and deck scuppers were missing closure devices. 46 CFR 184.702, 33 CFR 155.310 (a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2022
Resolution: Containment plugs and deck scupper closures were provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2020 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Port engine fuel return line was discovered leaking diesel fuel above engine at shut off valve between flexible hose and hard piping shut off valve. Vessel shall secure fuel leak prior to operating port engine. 46CFR176.25-50(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2020
Resolution: Valve removed and fuel line replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 July 2020 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition and fit for the service for which they are intended: Engine starting system. Alternate methods of starting shall be checked. Device/actuation spring on port and stbd engines used for operating station engine shutdowns was discovered altered with zip ties to function properly. Repair/replace as per manufacturer requirements. 46CFR176.25-10(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2020
Resolution: Vessel replaced spring to actuator and installed and metal bracket to hold spring to allow proper function.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2020 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended: (4) Generators. All generators, motors, lighting fixtures and circuit interrupting devices located in spaces or areas which may contain flammable vapors shall be checked. Starboard generator would not start at time of inspection. Vessel was able to get generator to properly function prior to marine inspector’s departure from vessel. 46CFR176.25-15(a)
Action required: 10 - Deficiency Rectified
Resolved 20 July 2020
Resolution: Company engineer repaired generator to allow for starting prior to marine inspector departure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2020 Resolved
A vessel must have one or more ring life buoys as follows: (c) At least one ring life buoy must be fitted with a lifeline. The lifeline bag attached to two of the life buoys onboard had a zip tie to secure the lifeline from slipping out of the bag. The rendered the ability for the line to readily release from the bag. Vessel shall stow lifeline with a different arrangement which does not prevent the lifeline from being casted rapidly. 46CFR180.70(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2020
Resolution: Vessel removed zip tie and replaced with breakaway tie.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2020 Resolved
All life preservers shall be of an approved type. Three lifejackets onboard had worn retroreflective material attached. Vessel shall replace retroreflective material to meet 46CFR180.25-25 or replace with new lifejackets. 46CFR180.25-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2020
Resolution: Vessel replaced all 3 lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 July 2020 Resolved
Each survival craft required on a vessel by this part must meet one of the following: (2) For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Each buoyant apparatus must have type II retroreflective material meeting subpart 164.018 of this chapter on each side and on each to be placed in accordance with this section. The majority of the retroreflective material on both lifefloats were worn with some areas covered with paint overspray rendering its ability to function as necessary. Vessel shall replace all retroreflective material. 46CFR180.200(a)(2), 46CFR160.027, 46CFR160.010-4(p)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2020
Resolution: Vessel replaced retroreflective tape.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 July 2020 Resolved
Vessels Operations Manual requires actions based upon wind speed. Vessels anemometer would not read wind speed, only wind direction, at time of inspection. Vessel shall ensure a proper functioning anemometer is onboard prior to jacking operations. CG 543 Policy Letter 07-02 Enclosure (1)11.C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2020
Resolution: Vessel replaced anemometer.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 July 2020 Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Oil was discovered pooled up at engine room bilge discharge suction box, leading to a future oil discharge if bilge pump was operated. Vessel shall remove all oil in box and around area which can lead to the accumulation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2020
Resolution: Vessel removed fuel from vicinity of and bilge suction area.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 May 2019 Resolved
Vessel is required to be equipped with an adequate rescue boat. During man overboard drill rescue boat engine would not operate and crewmember found excessive water in portable gas tank. New gas tank was provided and engine would still operate sporadically. Crew to service rescue boat and prove satisfactory operation to attending MI. 46 CFR 180.210 (b)(2),Correct prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2019
Resolution: Outboard engine was serviced and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 30 May 2019 Resolved
Each lifelfoat shall be equipped with two paddles. Paddles provided for both lifefloats were cracked from exposure. 46 CFR 180.15, correct in 7 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 30 May 2019
Resolution: New Paddles were proivded and installed for each life float.
Lifesaving › Lifefloat › Float Free
Issued 8 May 2018 Resolved
The stacked lifefloats are missing spacers between each other.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2018
Resolved 8 May 2018
Resolution: Spacers were provided. All sat.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 8 May 2018 Resolved
Draft markings are noticeably incorrect.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2018
Resolved 8 May 2018
Resolution: Draft markings were redone correctly.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 May 2018 Resolved
Generator space emergency light is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 8 May 2018
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 May 2018 Resolved
Attached light is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2018
Resolved 8 May 2018
Resolution: Corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 May 2018 Resolved
Stern light lense is covered in black paint overspray.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2018
Resolved 8 May 2018
Resolution: Replaced lense. All sat.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 August 2017 Resolved
Dogs on watertight door on main deck were inoperable and need to be repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 7 September 2017
Resolution: Dogs were repaired.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 23 August 2017 Resolved
Load mark was not on the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 7 September 2017
Resolution: Load mark was painted on the hull.
Lifesaving › Lifefloat › Lifeline
Issued 23 August 2017 Resolved
Lifefloat lifeline was deteriorated and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 7 September 2017
Resolution: Lifeline was replaced with new line.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 August 2017 Resolved
Fire control plan is not current; it does not reflect the current layout of fire adn safety items onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 August 2020
Resolved 20 July 2020
Resolution: Updated.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2017 Resolved
Upon Arrival in Venice, LA and Prior to placing the vessel back into opertion or departing Venice, LA. Contact USCG Sector New Orleans.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2017
Resolved 28 February 2017
Resolution: Received Transit plan and conducted courtesy safety inspection for transit.
Lifesaving › Lifefloat › Painter
Issued 25 April 2016 Resolved
Lifefloat painter line catches in tightly packed coil. Replace coil to ensure readiness for float free arrangement.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2016
Resolved 27 April 2016
Resolution: Painter recoiled to allow float free arrangement.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 April 2016 Resolved
Lines attaching waterlights to two (2) ring buoys decaying/not in a servicable condition.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 27 April 2016
Resolution: Vessel replaced lines.
Accommodation/Occupational Safety › Ventilation › General
Issued 25 April 2016 Resolved
Ventilation on port side of engine room wasted through to above the accomodation space. crop and renew to ensure continuity of barrier beteween engine and accomodation spaces.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 2 May 2016
Resolution: Vessel cropped and renewed wasted ventilation duct and surrounding deck.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 25 April 2016 Resolved
Marine sanitation device missing approval placard and posted operating instructions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 2 May 2016
Resolution: Vessel acquired and attached identification plate and operating instructions.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 April 2016 Resolved
Engine room distribution panel missing blank and directory needs to be updated.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 2 May 2016
Resolution: Vessel installed blank and updated directory.
Stability › Watertight Integrity › General
Issued 25 April 2016 Resolved
Engine room escape hatch does not completely dog tight. Adjust dogs to ensure watertight enclosure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 27 April 2016
Resolution: Vessel adjusted dogs to facilitate watertight integrity and emergency escape.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 25 April 2016 Resolved
Port generator inoperative. Show proper operation to attending marine inspector.
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 27 April 2016
Resolution: Vessel changed starter and demonstrated proper operation.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 25 April 2016 Resolved
Shore tie breaker removed. Prove disconnection of or remove shore tie cable.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 27 April 2016
Resolution: Vessel removed shore tie cable and blanked off switchboard opening.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 25 April 2016 Resolved
Paint locker equipped with fixed fire extinguisher that does not have a closure for the vent. Demonstrate ability to acheive vapor tightness.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 2 May 2016
Resolution: Vessel installed ventilation closure.

Casualty record · 1

15 February 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6103671