Records from 2021 to 2026. Most recent: inspection, 26 March 2026.
Documentation record
Registered dimensions (L × B × D)52.3 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA&M MANUFACTURING INC · CHIEFLAND, FL, UNITED STATES · built 2022
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portISLAMORADA, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 8 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Net Ton
9 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 7
26 March 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8331379
9 January 2026
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 8294360
1 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8082152
23 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8048662
2 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7888911
10 July 2023
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7740176
16 August 2021
Initial Certification · Construction Oversight · Deficiency Check · DAPI Audit · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7288759
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2026
Resolved
6 Adult life jackets need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 March 2026
Resolved
Distress signals need to be in a water tight container.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2025
Resolved
Vessel has a white life ring. According to the vessels routes and conditions a orange ring buoy is required.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2025
Resolved
High water alarms are backwards at helm. Label the alarms so crew members will be able to know exactly which alarm is going off.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2025
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 1 April 2025
Resolved
Fire buckets need to be labeled correctly with "FIRE BUCKET" written on each bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 1 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2025
Resolved
6 life jackets have been found to be dilapidated and need to be replaced. Passenger count is lower to 37 until new jackets are purchased and on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 April 2025
Resolved
Helm fire extinguisher needs to be mounted with bracket at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 3 April 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 April 2024
Resolved
Annual servicing of portable fire extinguishers had expired back in NOV 2023. Annual service of all portable fire extinguishers must be conducted prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2024
Resolved 2 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2024
Resolved
Both life floats are worn and cracked. Must conduct repairs/repaint with [name withheld] approved paint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 7 June 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 April 2024
Resolved
Must log monthly EPIRB test, quarterly fire and MOB drills.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 7 June 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 January 2023
Resolved
EPIRB came with none float free bracket. Owner chose to swap out EPIRB with new EPRIB with float free bracket. Must register new EPRIB and mount. Vessel is restricted to 1 mile from shore until cleared.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 23 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2023
Resolved
Vessel only had 42 adult life jackets. Vessel is required 45 Adult life jackets. Vessels passenger count is reduced by 3 until cleared.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 23 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2023
Resolved
Life ring floating light and both life floats floating lights did not have batteries. Install batteries and test to the satisfaction of attending CG Marine Inspector. Vessel is limited to day light hours only until cleared.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 23 February 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2023
Resolved
Vessel is missing draft/load marks. Vessel must place draft or load marks on both port and starboard sided stern and bow in accordance with thier stability letter.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 23 February 2023