MAURY USCG vessel records Sign in
← All vessels

ANKENY STREET

ANKENY STREET is a 1979 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in January 2025, along with 119 deficiencies and 4 operational controls.

Records from 1985 to 2025. Most recent: inspection, 9 January 2025.

Built
1979
Last inspected
9 January 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCD5556
167851
Flag
UNITED STATES
367411720
Maury page id
psix-167851

Inspections, by type

…with no type recorded7
Years with a record 37 calendar years (1985–2025)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.5 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portILWACO, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 9 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL9325MMSI 367411720 · active · compulsorily equipped · granted 20 January 2021, expires 20 January 2031
WCZ4458MMSI 367411720 · expired · compulsorily equipped · granted 27 May 2009, cancelled 12 October 2019
WCD5556MMSI 366555040 · expired · voluntarily equipped · granted 26 November 2008, cancelled 2 March 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

9 January 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8060561
18 January 2024 Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7850641
5 October 2023 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7802942
13 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611939
6 December 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601904
16 March 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7417585
24 January 2022 Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7384678
1 December 2020 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7103977
28 January 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6897748
14 January 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6890726
24 January 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6613758
11 January 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6336210
1 January 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6331091
6 December 2017 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6319393
6 January 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6066930
10 December 2015 Internal Structural Exam · COI Inspection · Drydock Exam · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5773485
17 March 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4817957
27 December 2011 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4214687
8 February 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3677205
9 December 2009 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3645787
12 March 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3426868
31 January 2008 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3131343
5 December 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3107514
8 February 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2869302
19 January 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2858525
18 January 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2556738
6 December 2005 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2526907
12 April 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2332154
3 March 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2294432
17 February 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2013510
6 February 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2000652
9 January 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1975250
29 January 2003 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1733428
4 February 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1483413
7 January 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1476301
5 February 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1403293
23 August 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1052765
10 August 2000 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 821856
11 July 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1052226
2 February 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 814604
1 December 1999 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1424844
30 June 1999 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1084030
14 June 1999 Type not recorded
No type recorded · Station Yaquina Bay · USCG Northwest District (CGD-NW) · Activity 1512525
30 March 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1117299
4 November 1998 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1438772
1 September 1998 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1419991
24 November 1997 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 774076
4 September 1997 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1368377
8 November 1996 Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1175933
6 September 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257273
5 September 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428673
12 September 1995 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1463919
3 July 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1387809
25 January 1995 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1134596
14 November 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 863624
7 November 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1177838
7 September 1994 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403827
6 April 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 856099
3 September 1993 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1139245
14 April 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1150630
25 February 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1150947
4 January 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1359463
5 February 1992 Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1267217
9 January 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 961122
11 April 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 909443
23 January 1991 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 913062
24 September 1990 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1211603
19 July 1990 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1225377
4 January 1990 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 919789
17 February 1989 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1348602
30 March 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 990163
17 March 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1031142
14 March 1988 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 984503
11 December 1987 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1002508
25 September 1987 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1017153
10 July 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1339439
15 June 1987 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1032006
21 May 1987 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1032005
10 April 1986 Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 999935
21 February 1986 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 986360
25 April 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1290605

Deficiency record · 119

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 January 2025 Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 46 CFR 181.405, 181.450, 181.500, 185.364, and 185.420(b), if it is not a ferry, and if it Is operating on a Coastwise or Oceans route. Vessel does not have an interconnected fore detection system and is operating on a Coastwise route. Vessel's route restricted to Limited Ccastwise until interconnected fire detection system installed. 46 CFR 175.100(c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 February 2025
Resolution: Witnessed installation of interconnected fire detection system.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 December 2023 Resolved
(a) Each vessel certificated to operate on an oceans route in cold water must (2) be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel is currently servicing a life float found during the annual inspection that was in need of servicing. Vessel currently has 01 other life float on board that has a max of 10 individuals. Vessel may continue to operate with no more than 10 indiviudals on the vessel at a time. This will remain in effect until the second life float is properly repaired to the satisfaction of the Marine Inspector. 46CFR180.202(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 19 December 2023
Resolution: Vessel completed repairs to the lifefloat and sent over photos for proof. Def has been cleared.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 October 2023 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel was unable to provide their service records for their fire-boy system. Obtain service records from the fire technician to show vessel has tested and maintained their fire system to the satisfaction of the Marine Inspector. 46 CFR 176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2023
Resolved 17 October 2023
Resolution: Submitted emailed copy of service report.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 5 October 2023 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (3) The pump is permanently mounted. Pumps and high level alarm were found not mounted. Mount all pumps to the satisfaction of the Marine Inspector. 46 CFR 183.520(e)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 17 October 2023
Resolution: submitted photo of bilge pump mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 October 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was found with 3 life jackets that were not serviceable. Vessel must procure 3 new life jackets to reach their passenger count. 46 CFR 180.71(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 21 October 2023
Resolution: Submitted photos of replaced lifejackets, all satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 5 October 2023 Resolved
(1) Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI. (i) The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred. Vessel's alcohol swabs were expired. Vessel must procure new alcohol swabs to the satisfaction of the Marine Inspector. 46CFR4.06-3(a)(1)(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 17 October 2023
Resolution: Submitted photo of newly purchased alcohol swabs that are current.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 October 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Vessel’s life float has tears in the flotation ring creating a negative effect in the seaworthiness of the survival craft. Must repair lifeboat to the satisfaction of the attending Marine Inspector. 46 CFR 180.175(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 19 December 2023
Resolution: Vessel completed repairs to the lifefloat and sent over photos for proof. Def has been cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 October 2023 Resolved
Each ring life buoy on a vessel must: (2) Be readily accessible. Vessel's ring life buoy was zip tied not allowing it to be readily accessible during man overboard drills. Vessel removed the zip tie and wont place another one on, corrected on the spot. 46 CFR 180.70(b)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
Resolution: Corrected on the spot.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 5 October 2023 Resolved
The operator must secure each Type III device in a manner which prevents discharge of sewage. Vessel had no means of securing sewage from being discharge into the ocean. Vessel installed a securing mechanism to the system. Corrected on the spot. 33 CFR 159.7(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have installed detectors in required spaces by 27Dec2022. Vessel has been limited to a Limited Coastwise route until detector installation has been verified by a Marine Inspector. 46 CFR 181.405(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2022
Resolved 3 February 2023
Resolution: Repaired with Marelon Forespar hull fittings.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 December 2022 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. No fire buckets were onboard; operator made three buckets during inspection, but they were not 2.5 gallons. Procure 3 fire buckets of 2.5 gallons to the satisfaction of the attending Marine Inspector
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2022
Resolved 19 December 2022
Resolution: Purchased/created new fire buckets of correct size.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 December 2022 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. 1 Life jacket light was inoperable. Vessel is limited to 24 personnel for Coastwise routes until life jacket is repaired to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2022
Resolved 19 December 2022
Resolution: Repaired life jacket light
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 December 2022 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Alcohol test strips were expired. Replace alcohol test strips to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2022
Resolved 19 December 2022
Resolution: Purchased new alcohol test strips
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 December 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Burn dressing was expired. Replace burn dressing to the the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2022
Resolved 19 December 2022
Resolution: Replaced burn dressing
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 December 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including... Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system. Operator had ineffective method for securing ventilation during activation of pre-engineered fire protection system. Create way to secure ventilation to the engine room during activation of pre-engineered system to the satisfaction of the attending Marine Inspector. 46 CFR 176.810(a)(2)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2022
Resolved 19 December 2022
Resolution: Created new method to secure ventilation to engine room
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following:...Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. Port engine was leaking coolant. Repair leak to the satisfaction of the attending marine inspector. Rectify deficiency by January 31, 2023 46 CFR 176.804(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 26 January 2023
Resolution: Owner refitted O-ring on coolant line and operational test witnessed by MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 December 2022 Resolved
Through hull fittings and shutoff valves shall be metal. In the case of nonmetallic hulls, materials which will afford an equal degree of safety and heat resistivity as that afforded by the hull may be approved. 2 vent pipes did not have proper through hull fittings. Submit repair proposal prior to starting work. Once proposal is approved, repair to the satisfaction of the attending Marine Inspector. Rectify deficiency during next drydock. 46 CFR 182.40-1(a)(3) "OLD T"
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 January 2024
Resolved 26 January 2023
Resolution: Verified installation of monel fittings on hull.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 December 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Stern light did not work. Vessel repaired light during inspection. No further action is needed. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 December 2022
Resolved 6 December 2022
Resolution: Vessel repaired light during inspection. No further action is needed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 March 2022 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The EPIRB hydrostatic release unit is expired. The vessel is restricted in operations to no more than 3 nautical miles from shore until the hydrostatic release unit is replaced. 46CFR180.64
Action required: 705 - Other - as specified
Resolved 22 March 2022
Resolution: Operator replaced hydrostatic release to the satisfaction of the MI.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 March 2022 Resolved
A vessel must comply with the applicable requirements for any radio installation as set forth in 47 CFR part 80. The vessel's DSC-VHF radio did not display the vessel's MMSI number or GPS Lat/Long coordinates. Provide proof of proper DSC functionality to the satisfaction of the Marine Inspector. 46CFR184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 22 March 2022
Resolution: Operator provided proof MMSI and LAT/LONG programmed into VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 March 2022 Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of life buoy of not less than 24 inches in diameter. The vessel's life buoy was not maintained. Service life buoy IAW manufacturer's instructions or replace in kind. 46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 22 March 2022
Resolution: Operator provided proof of ring life buoy maintenance to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2022 Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard satisfactory to the cognizant OCMI. The vessel's fire buckets did not have the attached lanyards. The operator installed lanyards to the three 2.5 gallon fire buckets.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 March 2022
Resolution: Operator installed lanyards to the fire buckets in the presence of the attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 December 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts, U.S. Coast Pilot or similar publication, Coast Guard Light list, Tide tables, & Current tables. Vessel did not have up-to-date the above reference items.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 1 January 2021
Resolved 31 December 2020
Resolution: Picture provided with updated charts, light list and Coast pilot.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 December 2020 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each buoyant apparatus. The number of persons capacity must be marked or painted in clearly legible letters and numbers on each buoyant apparatus. Vessel had 02 BA without the vessel's name and capacity.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 January 2021
Resolved 31 December 2020
Resolution: Provided picture with stenciled vessel's name and capacity on buyant apparatus.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 December 2020 Resolved
Each ring life buoy on a vessel must: Be readily accessible;Be stowed in a way that it can be rapidly cast loose. Vessel ring life buoy was not readily accessible and could not be rapidly cast loose.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 1 January 2021
Resolved 31 December 2020
Resolution: Provided picture of relocated ring buoy and stenciled vessel name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 December 2020 Resolved
Shutoff valves installed so as to close against the fuel flow. The valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Vessel's remote valve connection needs to be made with referenced connections.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 1 January 2021
Resolved 31 December 2020
Resolution: Picture provided of proper connection of the remote fuel shutoff valve.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 December 2020 Resolved
Licenses for ship stations in the maritime services will normally be issued for a term of ten years from the date of original issuance, or renewal. Vessel's FCC license was expired.*Note* Inform USCG if call sign changes
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 1 January 2021
Resolved 20 January 2021
Resolution: Vessel owner renewed FCC license.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 January 2020 Resolved
Portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. One (01) 40-B:C fire extinguisher was not charged. A licensed servicing agency must recharge the fire extinguisher in accordance with NFPA 10. The vessel is prohibited from carrying passengers for hire until this is completed. 46 CFR 176.810(b)(1)(i)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2020
Resolved 31 January 2020
Resolution: Operator provided pictures of the recharged fire extinguisher with the corresponding service tag showing a recharge of 31JAN2020.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 January 2019 Resolved
Vessel's EPIRB hydrostatic release expired this year and requires replacement IAW 46 CFR 180.46.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 29 January 2019
Resolution: Owner replaced hydrostatic release unit for EPIRB. New expiration date is February 2021.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 January 2019 Resolved
Vessel's first aid kit had expired items. Replace items IAW 46 CFR 184.710.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 29 January 2019
Resolution: Owner provided proof of requisition for replacement of expired medical kit items.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 January 2019 Resolved
Vessel's copy of the Coast Guard Light List was not up-to-date. Update Light List IAW 46 CFR 184.420.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 29 January 2019
Resolution: Owner provided proof of updated Light List.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 January 2019 Resolved
Vessel's submersible electric bilge pump located in the engine room does not have a positive shutoff valve installed at the hull penetration. Install positive shutoff valve IAW 46 CFR 182.520.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 7 February 2019
Resolution: Recieved photo of skin valve installed. Deficiency cleared to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2019 Resolved
Vessel's battery installation in the engine room does not have a cover. Batteries shall be effectively screened by a cage or similiar structure to minimize danger of accidental spark across terminals. 46 CFR 183.05-20 "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 29 January 2019
Resolution: Owner provided proof of installation of cover for Engine Room battery bank.
Lifesaving › Hand Flares › Expired
Issued 6 December 2017 Resolved
Vessel's hand flares expired this year and require replacement IAW 46 CFR 180.68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 14 December 2017
Resolution: Operator provided photographic proof of corrective action.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 December 2017 Resolved
Operator did not have records of random test results and requires such documents IAW 46 CFR 16.210.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 7 December 2017
Resolution: Operator provided copies of missing documentation via email.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 December 2017 Resolved
Vessel had wing-nut type fasterners on battery terminals and requires mechanical fasteners IAW 46 CFR 183.05-20(c) (Old T).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 14 December 2017
Resolution: Operator provided photographic proof of corrective action.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 6 December 2017 Resolved
FCC Safety Radiotelephony Certificate expired and requires renewal IAW 47 CFR 80.59.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 24 January 2019
Resolution: FCC Safety Radiotelephone Certificate is renewed, and verified during Annual COI Inspection.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 10 December 2015 Resolved
Install VHR Radio with DDSC capabilities. Have certified FCC technician test equipment and update the FCC safety certificate. 47CFR80.905
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 18 February 2016
Resolution: VHF-DSC Deficiency cleared due to uncertaininy regarding the required class of VHF Radio. Awaiting guidance from Headquarters / FCC.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 December 2015 Resolved
Procure 2016 Light List and Coast Pilot publications. 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 18 February 2016
Resolution: Owner procured Light List and Coast Pilot.
Lifesaving › Hand Flares › Expired
Issued 17 March 2014 Resolved
Provide proper amount of flares as per 46 CFR 180.68.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 23 March 2014
Resolution: Own purchased 6 red and 6 orange hand held flares.
Lifesaving › Lifejacket/PFD (Type IV) › Lights
Issued 17 March 2014 Resolved
Replace batteries in all water lights as per 46 CFR 180.30-1(b).
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 23 March 2014
Resolution: Batteries were replaced in all water lights on vsl.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 March 2014 Resolved
Provide current coast pilot and light list as per 46 CFR 185.20-35.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 23 March 2014
Resolution: Owner provided a 2014 Coast Pilot and Light List.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2014 Resolved
Provide machinery guards on port and STBD engines as per 46 CFR 177.35-15.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 23 March 2014
Resolution: Owner placed a guard plate in front of the vessel''s engines where the belts were exposed, port and STBD.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 February 2010 Resolved
Properly label lifejacket stowage compartment in fwd accomodation space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 17 February 2010
Resolution: Properly labeled lifejacket stowage compartment
Stability › Freeing Ports › General
Issued 9 February 2010 Resolved
Remove or prove proper operation of freeing port covers
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 16 March 2010
Resolution: Proved proper operation of freeing port covers.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 February 2010 Resolved
Properly label topside lifering buoy with the vessel's name.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 February 2010
Resolution: Labeled life ring buoy with the name of the vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 January 2007 Resolved
Properly dead end identified exposed wiring in engine room.
Action required: 705 - Other - as specified
Due 18 January 2007
Resolved 18 January 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 January 2007 Resolved
Replace one child PFD with bad clasp.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 9 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 January 2007 Resolved
Replace expired items in the first aid kit to include apirin and eye wash.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 9 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 18 January 2006 Resolved
Provide globe for port engine room light fixture.
Due 18 January 2006
Resolved 18 January 2006
Lifesaving › Lifefloat › Paddle
Issued 18 January 2006 Resolved
Lable paddles and attach to lifefloats.
Due 18 January 2006
Resolved 18 January 2006
Fire Fighting › Fire Bucket › Stenciling
Issued 18 January 2006 Resolved
Stencil vessel name and attach lanyard to the three 2.5 gallon fire buckets.
Due 18 January 2006
Resolved 18 January 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 December 2005 Resolved
Fold back & tape dead-ended elctrical wire in way of sewage tank compartment.
Due 6 January 2006
Resolved 6 December 2005
Stability › Watertight Integrity › General
Issued 6 December 2005 Resolved
Properly seal PVC pipe penetration coming from bait tank in way of forward Lazarette bulkhead.
Due 6 January 2006
Resolved 6 December 2005
Documentation › Logs/Records › Drug Test Records
Issued 3 March 2005 Resolved
Provide proof of crew enrollment in the random drug testing program.
Due 3 April 2005
Resolved 6 March 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 March 2005 Resolved
Remove expired first aid kit supplies and add Ammonia Inhalants to the first aid kit supplies.
Due 3 April 2005
Resolved 6 March 2005
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 3 March 2005 Resolved
Renew the weak link for the 15 passenger buoy apparatus.
Due 3 April 2005
Resolved 6 March 2005
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 3 March 2005 Resolved
Install a waterlight for the 10 passenger buoy apparatus.
Due 3 April 2005
Resolved 6 March 2005
Stability › Watertight Integrity › General
Issued 3 March 2005 Resolved
Make all penetrations in the bulkhead watertight.
Due 3 April 2005
Resolved 6 March 2005
Lifesaving › Lifebuoys › Quantity
Issued 3 March 2005 Resolved
Renew the life ring and properly label the life ring IAW 46 CFR 604(b)
Due 3 April 2005
Resolved 6 March 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 3 March 2005 Resolved
Replace plastic clip (ITW Nexus Fastex #SR1) on 9 KAPOK Type I Adult PFDs IAW 46 CFR 160.060-3a. Vessel is restricted in carrying 14 passengers for hire until this requirement is resolved.
Due 3 April 2005
Resolved 12 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 March 2005 Resolved
Properly label 3 Adult PFDs with the ship's name.
Due 3 April 2005
Resolved 3 March 2005
Documentation › Logs/Records › Logbook (official)
Issued 3 March 2005 Resolved
Provide proof of senior designation letter.
Due 3 April 2005
Resolved 3 March 2005
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 February 2004 Resolved
Provide non-expired medication for First Aid Kit. LEGACY COMPONENT DESC: Medicine Chest
Due 6 March 2004
Resolved 17 February 2004
Resolution: Provided.
Navigation › Piloting/Steering
Issued 6 February 2004 Resolved
Re-new all navigation publications per 46 CFR 184.420. LEGACY COMPONENT DESC: Coast Guard Light List
Due 6 March 2004
Resolved 17 February 2004
Resolution: renewed.
Lifesaving › Lifebuoys
Issued 6 February 2004 Resolved
Provide 3-6 foot lanyard with quick release devise for life ring water light per 46 CFR 180.70. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 17 February 2004
Resolution: Provided.
Lifesaving › Lifebuoys
Issued 6 February 2004 Resolved
Provide & install non-expired batteries for all water lights. LEGACY COMPONENT DESC: Water light
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 17 February 2004
Resolution: provided.
Navigation › Piloting/Steering
Issued 6 February 2004 Resolved
Update charts per Notice to Mariners. LEGACY COMPONENT DESC: Marine Charts
Due 6 March 2004
Resolved 17 February 2004
Resolution: Chart updated.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 February 2004 Resolved
Place V-belt protective shrouds back on both engines. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 17 February 2004
Resolution: Provided.
Lifesaving › Lifejacket/PFD (Type III)
Issued 6 February 2004 Resolved
Provide retro-reflective material on front right shoulder area for one adult PFD. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Affixed retro-reflective tape.
Documentation › Logs/Records
Issued 6 February 2004 Resolved
Provide a description for training. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Provided description.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 6 February 2004 Resolved
Provide tide and current tables.
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Provided tables.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 February 2004 Resolved
Provide securing mechanism for overboard sewage discharge valve.
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Secured valve with lock and chain.
Stability › Unintentional Flooding
Issued 6 February 2004 Resolved
Double clamp hose connected to sewage overboard discharge through hull fitting. LEGACY COMPONENT DESC: Sewage overboard discharge hose
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Double clamped hose.
Stability › Unintentional Flooding
Issued 6 February 2004 Resolved
Provide securing mechanism for both engine space hatches. LEGACY COMPONENT DESC: Engine space hatches
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Provided securing mechanisms.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 6 February 2004 Resolved
Make engine space forward and aft bulkheads fume tight. LEGACY COMPONENT DESC: Engine space
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Made engine space bulkheads fume tight.
Lifesaving › Buoyant Apparatus
Issued 4 February 2002 Resolved
Install waterlight for 10 person lifefloat IAW 46 CFR 180.175 LEGACY COMPONENT DESC: Waterlight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 8 February 2002
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 4 February 2002 Resolved
Add retro-reflective tape to back of one lifejacket found during inspection. IAW 46 CFR 185.604 (h)
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 February 2002 Resolved
Replace expired items in first aid kit with new IAW 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 4 February 2002 Resolved
Remove paint blocking fuel vent. IAW 46 CFR 182.450
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Stability › Watertight Integrity
Issued 4 February 2002 Resolved
Install securing device to lazarette hatch. IAW 46 CFR 171.124
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Stability › Watertight Integrity
Issued 4 February 2002 Resolved
Plug two holes in aft engineroom bulkhead, port side and make conduit for wire run on starboard side watertight. IAW 46 CFR 179.360
Due 5 February 2002
Resolved 5 February 2002
Documentation
Issued 11 July 2000 Resolved
PROVIDE A VALID RADIOTELEPHONY CERTIFICATE PRIOR TO 11 AUG 00.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Fire Fighting
Issued 30 March 1999 Resolved
SUBMIT PLANS FOR APPROVAL OF FIXED FIREFIGHTING SYSTEM. UPON APPROVAL OF_x001C_ PLANS, COMPLETE INSTALLATION OF SYSTEM AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE ADEQUATE FIRST AID KIT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE PROPERLY OPERATING EPIRB PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
RENEW AND PROPERLY INSTALL PAINTER TO BUOYANT APPARATUS PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE PROPER LINE TO WATER LIGHT/RINGBUOY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 5 September 1996 Resolved
COMPLETE 6-YEAR MAINTENANCE ON B-I EXTINGUISHER AND B-II EXTINGUISHER WITH 1990 DATE OF MANUFACTURE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
PROPERLY LINE BATTERY BOXES WITH SUITABLE MATERIAL.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Lifesaving
Issued 5 September 1996 Resolved
PROPERLY ATTACH WATERLIGHT TO LIFE FLOAT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Lifesaving
Issued 5 September 1996 Resolved
MODIFY OR REPLACE RESCUE LADDER TO INCLUDE SATISFACTORY PLATFORM TO RECOVERHELPLESS PERSON FROM THE WATER.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Lifesaving
Issued 5 September 1996 Resolved
PROVIDE 2 ADDITIONAL ADULT LIFE PRESERVERS TO BRING TOTAL TO 24. VESSEL ISLIMITED TO 20 PASSENGERS UNTIL COMPLETED.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Navigation
Issued 7 September 1994 Resolved
PROVE PROPER OPERATION OF ELECTRONIC NAVIGATION EQUIPMENT, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Lifesaving
Issued 7 September 1994 Resolved
POST AN EMERGENCY CHECK-OFF LIST VISIBLE TO PASSENGERS AND CREW.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Documentation
Issued 7 September 1994 Resolved
PROVIDE FCC OPERATOR'S LICENSE, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Documentation
Issued 7 September 1994 Resolved
PROVIDE VALID FCC RADIOTELEPHONY SAFETY CERTIFICATE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Documentation
Issued 7 September 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE ENROLLMENT IN AN APPROVED DRUGTESTING PROGRAM.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Engineering
Issued 7 September 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF MAIN PROPULSION ENGINES.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Lifesaving
Issued 7 September 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE VALID EPIRB BATTERY.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Construction/Loadline
Issued 7 September 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF BILGE PUMPS.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Construction/Loadline
Issued 9 January 1992 Resolved
PROVIDE SECURING DEVICE FOR ENGINE ROOM CENTER HATCH.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Lifesaving
Issued 9 January 1992 Resolved
PROVIDE 7 ADDITIONAL PFD LIGHTS.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Navigation
Issued 9 January 1992 Resolved
REPAIR MASTHEAD LIGHT.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Lifesaving
Issued 9 January 1992 Resolved
PROVIDE CLASS "A" OR 406 EPIRB.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Lifesaving
Issued 9 January 1992 Resolved
REPAIR CRACKS IN BUOYANT APPARATUS.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Lifesaving
Issued 9 January 1992 Resolved
REPAINT VESSEL NAME AND CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Navigation
Issued 23 January 1991 Resolved
PROVE SATISFACTORY OPERATION OF MASTHEAD LIGHT.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Fire Fighting
Issued 23 January 1991 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE TWO SATISFACTORY B-II_x001C_ FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Construction/Loadline
Issued 23 January 1991 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPLACE GASKETS ON ENGINEROOM_x001C_ HATCHES AND PROVE WATERTIGHTNESS IN FRONT OF USCG INSPECTOR.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Lifesaving
Issued 10 July 1987 Resolved
VESSEL RESTRICTED TO CARRYING 22 TOTAL PERSONS UNIL 8 ADDITIONAL ACCEPTABLE ADULT LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 10 July 1987
Resolved 10 July 1987
Fire Fighting
Issued 21 May 1987 Resolved
PROVIDE AN ADDITIONAL B-II FIRE EXTINGUISHER FOR THE GALLEY AREA ( A TOTAL OF 3 B-II EXTINGUISHERS ARE REQUIRED.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Engineering
Issued 21 May 1987 Resolved
PROVIDE CHECK VALVE IN DISCHARGE LINE FOR ELECTRIC BILGE PUMP (IN ACCORDANCE WITH 46 CFR 182.25-5(C)).
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Documentation
Issued 21 May 1987 Resolved
PROVIDE AN EMERGENCY CHECK-OFF LIST FOR VESSEL (IN ACCORDANCE WITH 46 CFR 185.25).
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Navigation
Issued 21 May 1987 Resolved
MAKE HORN OPERATIONAL.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Lifesaving
Issued 21 May 1987 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, RENEW PADDLES FOR BUOYANT APPARATUS AND RENEW THE LINE AROUND THE INSIDE OF THE BUOYANT APPARATUS AND THE LINE ATTACHING THE WATERLIGHT TO THE BUOYANT APPARATUS.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Lifesaving
Issued 21 May 1987 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, RENEW ALL LINES ON RING BUOY.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Lifesaving
Issued 21 May 1987 Resolved
VESSEL RESTRICTED TO CARRYING A MAXIMUM OF 18 TOTAL PERSONS UNTIL 4 MORE ACCEPTABLE ADULT LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Engineering
Issued 25 April 1985 Resolved
PROVE PROPER OPERATION OF THE PILOT HOUSE ENGINE CONTROLS.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.