MAURY USCG vessel records Sign in
← All vessels

MS EMELIE ROSE

MS EMELIE ROSE is a 2001 offshore supply vessel. The Coast Guard has recorded 37 inspections since 2000, most recently in March 2026, along with 31 deficiencies and 1 casualty investigation in 2013.

Records from 2000 to 2026. Most recent: inspection, 24 March 2026.

Built
2001
Last inspected
24 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9260794 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG8877
Flag
UNITED STATES
367581980
Maury page id
psix-16797

Inspections, by type

…with no type recorded2
Years with a record 23 calendar years (2000–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)130.8 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 90 / net 50
ITC dimensions (L × B × D)130.8 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 423 / net 136
BuilderBOLLINGER MARINE FABRICAT · AMELIA, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 July 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
423 - Convention (Subpart B), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
136 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG8877MMSI 367581980 · active · compulsorily equipped · granted 23 May 2023, expires 4 July 2033
WDD6899MMSI 367179190 · expired · compulsorily equipped · granted 10 April 2007, cancelled 10 June 2017
WDC7740MMSI 367076050 · expired · compulsorily equipped · granted 10 November 2005, cancelled 16 January 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 37

24 March 2026 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8308866
9 March 2026 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8306793
30 April 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8094866
1 May 2024 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7904405
9 April 2024 Internal Structural Exam · Examination of Repairs · Deficiency Check · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7891844
15 July 2023 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7744393
15 May 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7688555
1 February 2023 Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 7630961
25 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7457299
8 October 2021 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7335188
7 October 2021 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7328303
8 March 2021 Drydock Exam · Cargo Tank Internal · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7152300
1 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6946659
8 February 2019 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6622259
17 May 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6417232
23 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6153078
29 February 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5823720
18 February 2016 Cargo Tank Internal · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5817879
12 June 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4340699
18 February 2011 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3947879
26 March 2009 Internal Structural Exam · Re-Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3426373
9 June 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3231540
2 July 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2980905
22 September 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2784807
10 March 2006 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2578946
17 June 2005 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2393416
17 March 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2312541
4 October 2004 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2212834
5 August 2004 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2156749
22 March 2004 Cargo Tank Internal · Internal Structural Exam · Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2029219
18 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2008539
13 February 2004 MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2006218
17 April 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1775318
20 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1600655
15 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 59485
16 March 2001 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418883
7 February 2000 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373313

Deficiency record · 31

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2025 Resolved
Standby vessels must have, Coast Guard approved life preservers for 50 percent of the number of persons on the most populated facility that the standby vessel is designated to assist. Vessel's COI states approved for standby service of 75 persons. Provide sufficient number of life jackets prior to operating as a standby vessel but no later then 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 2 May 2025
Resolution: Appropriate number of life jackets with vessel name marked and appropriate light attached are onboard vessel.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 April 2025 Resolved
Standby vessels must have a fire monitor with a minimum flow rate of, at least, 500 gallons per minute. Prove proper operation of vessel's installed fire monitor prior to operating as a standby vessel but no later then 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 2 May 2025
Resolution: Objective evidence provided showing the fire monitor operates satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2023 Resolved
The installation and inspection of materials, machinery, and piping must comply with Subchapter F. Nonmetallic flexible hoses must be in accordance with SAE J1942 and may be installed in lube oil and fuel systems. A nonmetallic fuel hose on the port generator was found to be severely chaffed. The crew satisfactorily replaced the fuel hose. - 46 CFR Part 128.110(a) / 46 CFR Part 56.60-25(b)(1)
Action required: 10 - Deficiency Rectified
Due 15 May 2023
Resolved 15 May 2023
Resolution: The crew replaced the fuel hose to the satisfaction of the attending MArine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2023 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. The watertight door leading to the engine room space was observed to have air passing through and was not watertight. The crew reworked the doors gasket, and the door was made watertight. - 46 CFR Part 127.230
Action required: 10 - Deficiency Rectified
Due 15 May 2023
Resolved 15 May 2023
Resolution: The crew reworked the doors gasket, and the door was made watertight to the satisfaction of the attending Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 May 2023 Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. An emergency light near the aft engine room escape hatch extinguished during testing of emergency lighting. The crew replaced the lights battery and proved satisfactory operation of the light. - 46 CFR Part 129.440(a)
Action required: 10 - Deficiency Rectified
Due 15 May 2023
Resolved 15 May 2023
Resolution: The crew replaced the lights battery and proved operation of the light to the satisfaction of the attending USCG Marine Inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 May 2022 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Captain of the vessel was unable to provide proof he holds a valid medical certificate. Captain must obtain a valid medical certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2023
Resolution: The Master of the vessel held a valid medical certificate satisfactory to the attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2021 Resolved
Except in an emergency, no repairs or alterations to the hull or machinery, or to equipment that affects the safety of the OSV, may be made without notice to the cognizant OCMI in the inspection zone where the repairs or alterations are to be made. When the repairs or alterations have been made, notice must be given to this OCMI as soon as practicable. Vessel is permitted to transit to Superior Shipyard in Golden Meadow, LA to conduct repairs. Vessel may not conduct any other movements or be in service until repairs are completed. 46 CFR 126.150(a)
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 18 October 2021
Resolved 18 October 2021
Resolution: Repairs completed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 March 2009 Resolved
Replace eyewash solution on the main deck.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 1 April 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 March 2009 Resolved
Conduct man overboard drill to the satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2009
Stability › Watertight Integrity › Weathertight Enclosure
Issued 26 March 2009 Resolved
Stencil engine room doors with proper markings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 9 June 2008 Resolved
Vessel had deck freezer installed within 10 feet of P/V vent for Methanol. Resolve by the following. 1) Remove Deck freezer, or 2) Install explosion proof conduit and electrical box and install intrinsically safe motors and controllers, or 3) Move Deck freezer with all electrical connections more than 10 feet from P/V Vent. Correct within 30 days or prior to using Methanol Cargo System.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2008
Resolved 31 March 2009
Communications › Radio Communications › EPIRB
Issued 9 June 2008 Resolved
Replace EPIRB antenna and have EPIRB reflect acurate battery replacement date, or Replace EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 June 2008 Resolved
Fwd Bilge alarm light does not work, show proper operation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 9 June 2008 Resolved
Label Emergency Shut-down for the following: 1) Ventillation 2) Mud-Pump 3) F/O txfr pump 4) Methanol Cargo Pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 July 2007 Resolved
Paint Running side lights background matte black.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2007
Resolution: COMPLETED
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 2 July 2007 Resolved
Provide Fuel Oil Transfer Procedures.
Due 17 July 2007
Resolved 3 July 2007
Resolution: COMPLETED
Fire Fighting › Means of Escape › Doorways
Issued 2 July 2007 Resolved
Demonstrate proper operation of engine room escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2007
Resolution: COMPLETED
Electrical › Lighting (service) › Lighting Fixture
Issued 2 July 2007 Resolved
Renew engine room hallway light cover
Due 15 July 2007
Resolved 3 July 2007
Resolution: COMPLETED
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 July 2007 Resolved
Label starboard breaker panel
Due 17 July 2007
Resolved 3 July 2007
Resolution: COMPLETED
Engineering › Bilge Water Management System › Manifold
Issued 2 July 2007 Resolved
Label bilge valve, that was not labeled
Due 17 July 2007
Resolved 3 July 2007
Resolution: COMPLETED
Navigation › Piloting/Steering › Gyro Compass
Issued 22 March 2004 Resolved
Repair compass light, vessel restricted to day light operation until repaired.
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 5 August 2004
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 22 March 2004 Resolved
Provide third party certificate for main engine over speed devices prior to 22 April 2004.
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 5 August 2004
Communications › Internal Communications System › Sound-powered Telephone
Issued 22 March 2004 Resolved
Demonstrate proper operation of sound powered phone visual indication and general alarm visual indication and emergency power to the satisfaction of attending Coast Guard Marine Inspector prior to 22 April 2004.
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 5 August 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 March 2004 Resolved
Provide and install additional emergency lighting to illuminate engine room emergency escape hatch to the satisfaction of attending Coast Guard Marine Inspector prior to 22 April 2004.
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 5 August 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 March 2004 Resolved
Demonstrate proper operation of both liquid mud engine driven pump to the satisfaction of an attending Coast Guard Marine Inspector prior to 22 April 2004.
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 5 August 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 22 March 2004 Resolved
Provide two twenty-pound dry chemical fire extinguishers prior to carriage of methanol and DOT potable tanks.
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 5 August 2004
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2004 Resolved
SEE NARRATIVE FOR SUMMARY OF HULL REPAIRS
Condition: Unknown
Due 22 April 2004
Resolved 22 April 2004
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 13 February 2004 Resolved
Failure to submit vessel security assessment report.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Vessel provided Vessel Security Assessment Report and Vessel Security Plan.
Stability › Watertight Integrity
Issued 17 April 2003 Resolved
Engine Room escape hatch in need of adjustment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2003
Resolution: Escape hatch was adjusted and lubricated.
Fire Fighting › Nozzles › Condition
Issued 17 April 2003 Resolved
Repair or replace forward main deck fire station nozzle.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2003
Resolution: Nozzle was soaked and freed up and made usable.
Lifesaving › Buoyant Apparatus
Issued 17 April 2003 Resolved
Untangle sea-painter and re-tie bites on lifelines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2003
Resolution: Discrepancies resolved.

Casualty record · 1

14 June 2013Major Marine Casualty · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · activity 4620193
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ODYSSEA ENDEAVOR (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.