← All vessels
ALAM BITARA
ALAM BITARA is a 1999 tank ship. The Coast Guard has recorded 26 inspections since 2000, most recently in November 2008, along with 18 deficiencies and 2 operational controls.
Records from 2000 to 2008. Most recent: inspection, 29 November 2008.
- Built
- 1999
- Last inspected
- 29 November 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9181003 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9MEA7
16810
Flag
MALAYSIA
—
Maury page id
psix-16810
Inspections, by type
…with no type recorded7
Years with a record
8 calendar years (2000–2008)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28932 - Convention (Subpart B), Gross Ton
11802 - Convention (Subpart B), Net Ton
45513 - Dead Weight, Ton
54649 - Displacement, Ton
11802 - Convention (Subpart B), Net Ton
45513 - Dead Weight, Ton
54649 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
29 November 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3371132
16 October 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3346003
7 October 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CHEM Renew · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3339948
7 June 2008
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3229512
19 September 2007
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3061151
14 September 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3057858
23 September 2006
COC-TVE Renew · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2783084
15 April 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2625546
7 September 2005
MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2486041
23 September 2004
Ballast Water Examination · COC-TVE Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2203393
23 August 2004
PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2174494
24 July 2004
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2142922
11 June 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2095293
4 April 2004
MTSA/ISPS Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2035561
31 March 2004
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2034647
24 February 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2011980
4 February 2004
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2000432
11 December 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1962285
3 December 2003
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1958271
3 December 2003
Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1958638
5 November 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1942780
13 August 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1874810
14 April 2003
Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1773727
12 August 2002
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1660063
11 October 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 282957
11 October 2000
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1055362
Deficiency record · 18
Engineering › Fuel Oil Service System › Pump
Issued 7 October 2008
Resolved
Vessel's number two fuel oil circulation pump mechanical seal is leaking excessively, additionally rags and threads were wrapped around area, vessel is to remove temporary rag containments and repair seal to satisfaction of classification society.
Engineering › Steering Gear System › Valve
Issued 7 October 2008
Resolved
Threaded fitting located between #2 steering gear hydraulic oil filter and hydraulic oil distribution box exhibited a leak with a rate of 25 drips per minute when the system was energized. Remove temporary bonding material on fitting and ensure seal is repaired to prevent hydraulic oil leakage to the satisfaction of the Coast Guard.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 19 September 2007
Resolved
VCS starboard side aft flange did not have one inch stud. Vessel is required to repair flange to met 46 CFR 39.20-1 prior to using the starboard aft VCS flange in the US.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 24 July 2004
Resolved
Provide clarification of audit completion date for the ship's SMC. The ship was issued a short term certificate by ABS on 08JUL04. The certificate states that the audit upon which the certificate is based was conducted on 06SEP04. The master provided documentation that a renewal audit was conducted on 08JUL04 with one outstanding non-conformity to be due by 06SEP04.
Construction/Loadline › Structures
Issued 11 December 2003
Resolved
The vessel may not conduct cargo operations in the US until permanent repairs are carried out to the satisfaction of the class society and a survey report attesting to the satisfactory repairs to cargo tank tops are provided to both the COTP NY and the first port where cargo ops will be conducted.
Engineering
Issued 3 December 2003
Resolved
Make repairs to number two boiler safety relief valve prior to departure from St. Croix.
Deck/Cargo
Issued 3 December 2003
Resolved
Make repairs to cargo tank five starboard prior to departure from St. Croix.
Operations/Management
Issued 3 December 2003
Resolved
Submit for review classification society or flag state approved casulaty analysis for cargo tank overpressurization discovered 3 Dec. 03.
Operations/Management
Issued 3 December 2003
Resolved
Provide statement from Master, Chief Mate and A.B. Vilis regarding over pressurization discovered 3 Dec. 03.
Deck/Cargo
Issued 3 December 2003
Resolved
Provide evidence of approval for cargo tank pressure/relief valve.
Deck/Cargo
Issued 3 December 2003
Resolved
Submit for review cargo/voyage plan prior to departure from St. Croix.
Deck/Cargo
Issued 3 December 2003
Resolved
Provide loading/discharge operational insturctions for multigrade cargoe's. Vessel permitted cargo operations for homogenous cargoes only until corrected.
Operations/Management
Issued 3 December 2003
Resolved
All void, ballast, and cargo tanks located within the cargo tank block should be monitored to check that no leakage has occurred from adjacent tanks. Monitoring shall include regular atmosphere checks for hydrocarbon content and soundings/ullaging of the tanks and deck condition.(continued it.#9)
Operations/Management
Issued 3 December 2003
Resolved
(continued from item 9) Monitoring required in item 8 to be completed at a minimum every three hours. Soundings, ullaging and atmosphere test results to be logged.
Personnel › Certificates/Documents/Licenses
Issued 13 August 2003
Resolved
Malysian endorsement for Philippine license # E1-0028073 is missing and shall be obtained prior to vessel departing the port of New York. LEGACY COMPONENT DESC: License, Second Assistant Engineer
Deck/Cargo › Vapor Control Systems
Issued 13 August 2003
Resolved
All ballast tank vent head flame screens destroyed by paint contamination and to be replaced to satisfaction of Lloyds prior to Sept 13, 2003. LEGACY COMPONENT DESC: Detonation Arresters
Deck/Cargo › Vapor Control Systems
Issued 13 August 2003
Resolved
1200 position locating studs found missing on all manifold vapor connection flange fittings and must be installed to Lloyds satisfaction prior to Sept 13, 2003. LEGACY COMPONENT DESC: Piping/Hoses
Fire Fighting › Firemans Outfit
Issued 13 August 2003
Resolved
One BA set found with ionoperative air valve and low air alarm. This to be repaired to Lloyds satisfaction prior to departing the port of NY. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.