MAURY USCG vessel records Sign in
← All vessels

ALAM BITARA

ALAM BITARA is a 1999 tank ship. The Coast Guard has recorded 26 inspections since 2000, most recently in November 2008, along with 18 deficiencies and 2 operational controls.

Records from 2000 to 2008. Most recent: inspection, 29 November 2008.

Built
1999
Last inspected
29 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9181003 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MALAYSIA
—
Maury page id
psix-16810

Inspections, by type

…with no type recorded7
Years with a record 8 calendar years (2000–2008)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28932 - Convention (Subpart B), Gross Ton
11802 - Convention (Subpart B), Net Ton
45513 - Dead Weight, Ton
54649 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

29 November 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3371132
16 October 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3346003
7 October 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CHEM Renew · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3339948
7 June 2008 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3229512
19 September 2007 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3061151
14 September 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3057858
23 September 2006 COC-TVE Renew · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2783084
15 April 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2625546
7 September 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2486041
23 September 2004 Ballast Water Examination · COC-TVE Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2203393
23 August 2004 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2174494
24 July 2004 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2142922
11 June 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2095293
4 April 2004 MTSA/ISPS Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2035561
31 March 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2034647
24 February 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2011980
4 February 2004 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2000432
11 December 2003 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1962285
3 December 2003 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1958271
3 December 2003 Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1958638
5 November 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1942780
13 August 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1874810
14 April 2003 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1773727
12 August 2002 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1660063
11 October 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 282957
11 October 2000 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1055362

Deficiency record · 18

Engineering › Fuel Oil Service System › Pump
Issued 7 October 2008 Resolved
Vessel's number two fuel oil circulation pump mechanical seal is leaking excessively, additionally rags and threads were wrapped around area, vessel is to remove temporary rag containments and repair seal to satisfaction of classification society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 November 2008
Resolved 16 October 2008
Resolution: Received class report attesting to satisfactory repair of #2 fuel oil circulation pump. Deficiency cleared.
Engineering › Steering Gear System › Valve
Issued 7 October 2008 Resolved
Threaded fitting located between #2 steering gear hydraulic oil filter and hydraulic oil distribution box exhibited a leak with a rate of 25 drips per minute when the system was energized. Remove temporary bonding material on fitting and ensure seal is repaired to prevent hydraulic oil leakage to the satisfaction of the Coast Guard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 October 2008
Resolved 7 October 2008
Resolution: Before the inspection was complete the chief engineer showed us the fitting and energized the system, we witnessed no leakage while the system was under pressure.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 19 September 2007 Resolved
VCS starboard side aft flange did not have one inch stud. Vessel is required to repair flange to met 46 CFR 39.20-1 prior to using the starboard aft VCS flange in the US.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 7 June 2008
Resolution: Deficiency Cleared.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 24 July 2004 Resolved
Provide clarification of audit completion date for the ship's SMC. The ship was issued a short term certificate by ABS on 08JUL04. The certificate states that the audit upon which the certificate is based was conducted on 06SEP04. The master provided documentation that a renewal audit was conducted on 08JUL04 with one outstanding non-conformity to be due by 06SEP04.
Action required: 705 - Other - as specified
Due 24 August 2004
Resolved 23 August 2004
Resolution: Received proper documentation from ABS satisfying requirement.
Construction/Loadline › Structures
Issued 11 December 2003 Resolved
The vessel may not conduct cargo operations in the US until permanent repairs are carried out to the satisfaction of the class society and a survey report attesting to the satisfactory repairs to cargo tank tops are provided to both the COTP NY and the first port where cargo ops will be conducted.
Action required: 15 - Rectify deficiencies by next port
Due 31 December 2003
Resolved 31 March 2004
Resolution: RECEIVED CLASS DOCUMENTS ATTESTING TO THE REPAIRS OF THE NO.5 (p/s) CARGO TANKS.
Engineering
Issued 3 December 2003 Resolved
Make repairs to number two boiler safety relief valve prior to departure from St. Croix.
Action required: 705 - Other - as specified
Resolved 3 December 2003
Deck/Cargo
Issued 3 December 2003 Resolved
Make repairs to cargo tank five starboard prior to departure from St. Croix.
Action required: 705 - Other - as specified
Resolved 11 December 2003
Resolution: See Activities New York item RS01.
Operations/Management
Issued 3 December 2003 Resolved
Submit for review classification society or flag state approved casulaty analysis for cargo tank overpressurization discovered 3 Dec. 03.
Action required: 705 - Other - as specified
Resolved 3 December 2003
Operations/Management
Issued 3 December 2003 Resolved
Provide statement from Master, Chief Mate and A.B. Vilis regarding over pressurization discovered 3 Dec. 03.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2003
Deck/Cargo
Issued 3 December 2003 Resolved
Provide evidence of approval for cargo tank pressure/relief valve.
Action required: 705 - Other - as specified
Resolved 11 December 2003
Resolution: Class approved
Deck/Cargo
Issued 3 December 2003 Resolved
Submit for review cargo/voyage plan prior to departure from St. Croix.
Action required: 705 - Other - as specified
Resolved 11 December 2003
Deck/Cargo
Issued 3 December 2003 Resolved
Provide loading/discharge operational insturctions for multigrade cargoe's. Vessel permitted cargo operations for homogenous cargoes only until corrected.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2003
Operations/Management
Issued 3 December 2003 Resolved
All void, ballast, and cargo tanks located within the cargo tank block should be monitored to check that no leakage has occurred from adjacent tanks. Monitoring shall include regular atmosphere checks for hydrocarbon content and soundings/ullaging of the tanks and deck condition.(continued it.#9)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2003
Operations/Management
Issued 3 December 2003 Resolved
(continued from item 9) Monitoring required in item 8 to be completed at a minimum every three hours. Soundings, ullaging and atmosphere test results to be logged.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2003
Personnel › Certificates/Documents/Licenses
Issued 13 August 2003 Resolved
Malysian endorsement for Philippine license # E1-0028073 is missing and shall be obtained prior to vessel departing the port of New York. LEGACY COMPONENT DESC: License, Second Assistant Engineer
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2003
Resolved 14 August 2003
Resolution: Faxed receipt for COR received this unit this date.
Deck/Cargo › Vapor Control Systems
Issued 13 August 2003 Resolved
All ballast tank vent head flame screens destroyed by paint contamination and to be replaced to satisfaction of Lloyds prior to Sept 13, 2003. LEGACY COMPONENT DESC: Detonation Arresters
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2003
Resolved 5 November 2003
Resolution: Received report from Lloyd''s.
Deck/Cargo › Vapor Control Systems
Issued 13 August 2003 Resolved
1200 position locating studs found missing on all manifold vapor connection flange fittings and must be installed to Lloyds satisfaction prior to Sept 13, 2003. LEGACY COMPONENT DESC: Piping/Hoses
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2003
Resolved 5 November 2003
Resolution: Received report from Lloyd''s
Fire Fighting › Firemans Outfit
Issued 13 August 2003 Resolved
One BA set found with ionoperative air valve and low air alarm. This to be repaired to Lloyds satisfaction prior to departing the port of NY. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Resolution: Lloyds report received this date, all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.