CRUDE LEVANTE
CRUDE LEVANTE is a 2021 tank ship. The Coast Guard has recorded 11 inspections since 2022, most recently in May 2025, along with 4 deficiencies — 3 with no resolution recorded — and 3 operational controls.
Records from 2022 to 2025. Most recent: operational control imposed, 12 May 2025.
- Built
- 2021
- Last inspected
- 12 May 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 3 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9899363 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5LAG4
1683543
Flag
LIBERIA
—
Maury page id
psix-1683543
Inspections, by type
…with no type recorded3
Years with a record
3 calendar years (2022–2025)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it82477 - Convention (Subpart B), Gross Ton
52007 - Convention (Subpart B), Net Ton
156828 - Dead Weight, Metric Ton
183750 - Displacement, Metric Ton
52007 - Convention (Subpart B), Net Ton
156828 - Dead Weight, Metric Ton
183750 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
12 May 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8133644
2 May 2025
COC-TVE Renew
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8127515
17 April 2023
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7670596
31 March 2023
COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7659953
15 February 2023
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7634008
7 February 2023
COE-Offshore
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7633510
12 December 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7608339
10 December 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7607128
23 May 2022
PSC A · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7457494
20 May 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7455520
16 May 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7451884
Deficiency record · 4
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 May 2025
No resolution recorded
Maintenance, testing and inspections shall be carried out bases on the guidelines developed by the organization. PSCO's found the fire dection system, foam applicators, EEBDs, fire extinguishers, local water mist for E/R, fixed CO2, SCBA Sets & Compressor are overdue for servicing. Vessel has an active dispensation letter from flag state valid till 10MAY2025.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 May 2025
No resolution recorded
Maintenance, testing and inspections of life saving appliances shall be carried out...PSCO's found immersion suits and life-jackets were overdue for servicing. Vessel has an active dispensation from flag state valid until 10MAY2025.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 May 2025
No resolution recorded
Oil tankers 20,000 DWT and above shall be provided with fixed hydrocarbon gas detection. Ship's fixed gas tests for O2, but sensor is not working. Dispensation valid until 12MAY25.
14 - Pollution Prevention › 141 - MARPOL Annex I › Cow operations and equipment manual
Issued 31 March 2023
Resolved
Every crude oil tanker of 20,000 tonnes deadweight and above delivered after 1 JUNE 1982, as defined in regulation 1.28.4, shall be fitted with a cargo tank cleaning system using crude oil washing. The administration shall ensure that the system fully complies with the requirements of this regulation within one year after the tanker was first engaged in the trade of carrying crude oil suitable for crude oil washing, whichever occurs later. Vessel has exceeded the time requirements and carriage requirements for the effectiveness of the crude oil washing system to be verified as indicted on the vessel's IOPP Certificate. Prior to carrying crude oil, the Administration shall ensure the effectiveness of the crude oil washing system. 16bc
MARPOL 2022 Annex I/33.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.