EL KRAKEN

EL KRAKEN is a 2022 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2021, most recently in April 2026, along with 27 deficiencies and 1 casualty investigation in 2023.

Records from 2021 to 2026. Most recent: inspection, 22 April 2026.

Built
2022
Last inspected
22 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2021–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM8759
1683959
Flag
UNITED STATES
Maury page id
psix-1683959

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 8.0 ft
Registered tonnagegross 39 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS LLC · SLIDELL, LA, UNITED STATES · built 2022
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

22 April 2026 In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8354053
4 December 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8275373
22 October 2025 Drydock Exam · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8257209
3 August 2025 Type not recorded
No type recorded · Station San Juan · USCG Southeast District (CGD-SE) · Activity 8203590
18 February 2025 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8081076
28 January 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7856779
24 January 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7850347
25 October 2023 Administrative Inspection · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7811271
2 February 2023 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7618336
16 January 2023 Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7622188
16 January 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7628989
16 March 2022 In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7404255
6 April 2021 Construction Oversight · Internal Structural Exam · Plan Review "T" Boat · Drydock Exam · Simplified Stability Test · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7374979

Deficiency record · 27

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 December 2025 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. The port side fire damper did not create a vapor tight seal. Adjust and repair fire damper and make it vapor/gas tight.
Action required: 10 - Deficiency Rectified
Resolved 4 December 2025
Resolution: 17c. Corrected the day of the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 December 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2.5 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. The three fire buckets were 5 gallons each and were not labeled. Obtain the correct size fire buckets and label them.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2025
Resolved 11 December 2025
Resolution: Sent photographic evidence of fire buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The visual indicator for the bilge pump in the aft compartment was inoperable. Repair the indicator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2025
Resolved 23 December 2025
Resolution: A new visual indicator was installed and tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 December 2025 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. 01 life float had fractures on the top surface. Repair the fractures with an approved repair kit or product according to [name withheld] manufacturer instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2026
Resolved 17 December 2025
Resolution: An approved [name withheld] Brand repair kit was applied and fractures have been repaired.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 October 2025 Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel is constructed with general purpose resin. The under deck of the engine room was found lacking of non-conbustible panels or materials. Install fire retardant insulation or similar. Provide the specs of the materials to be used to the USCG for approval, and prior installation in the under deck of the engine room compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2025
Resolved 28 April 2026
Resolution: South East District granted an appeal letter for not having non-combustible panels dated April 2026. Letter is in MISLE documents.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 February 2025 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The engine room ventilation on port and starboard side closed but did not stay shut. Repair to make sure the ventilation can remain shut on both sides. 46 CFR 182.465(h) 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2025
Resolution: Vessel sent videos and pictures of repairs to SSJ Duty Phone. Repairs show starboard and port side ventilation closed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 February 2025 Resolved
Each life jacket kept in a stowage container must be readily available. The life jackets were kept in zipped stowage bags that had to be ripped open to gain access to the life jackets. Rectified on the spot by vessel crew tearing open all bags. 46 CFR 180.78(a)(2) 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2025
Resolution: Rectified on the spot by vessel crew tearing open all bags. Vessel additionally sent pictures to SSJ Duty Phone of new lifejacket stowage without bags on 19Feb25.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 18 February 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessel Captain was unable to show inspection team how electronic chart receives updates. Demonstrate that the electronic chart receives updates and is up-to-date. 46 CFR 184.420(a)(1) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 10 March 2025
Resolution: Received a letter from Schafer & Brown certifying that EL KRAKEN's GPS has the latest update of nautical charts. Uploaded into documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 February 2025 Resolved
A vessel of more than 26 feet must carry a minimum of one life buoy. The life buoy on board was waterlogged and needs to be replaced. Replace with new life buoy. 46 CFR 180.70(a)(2) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 4 March 2025
Resolution: SSJ Duty Marine Inspector phone received image of new ring buoy. Found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 January 2024 Resolved
Vessel made contact with an object has suffered bent propellers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2024
Resolved 29 January 2024
Resolution: Both propellers were replaced. underwater survey conducted and no damages were found.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 January 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Provide a nautical chart with current updates. 46 CFR 184.420(a) 16C.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 7 February 2024
Resolution: Nautical chart was updated witrh notice to mariners current updates.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 January 2024 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Replace (01) portable flashlight that was found inoperative. 46 CFR 183.430 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 7 February 2024
Resolution: A new flashlight was purchased and put into service on board the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Master and crew were found not to be completely familiar with current emergency instructions that needs to be updated in accordance with 46 CFR 185.512 recommended emergency instructions format, adapting it to what the current vessel's arrangements and equipment. 46 CFR 185.510 16C.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 7 February 2024
Resolution: Emergency instructions format have been updated with current vessel's configuration and equipment available.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2024 Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following: (1) The location of emergency exits, survival craft embarkation areas, and ring life buoys; (2) The stowage location(s) of life jackets; (3) The proper method of donning and adjusting life jackets including a demonstration of the proper donning of a lifejacket, or (4) The location of the instruction placards for life jackets and other lifesaving devices; (5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master or crew. Crew members didn't met the requirements of the safety orientation when asked. Demonstrate proficiency in providing safety orientation complying with the requirements of 46 CFR 185.506 (above) and in presence of an attending USCG Marine Inspector. 46CFR185.512 16C.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 7 February 2024
Resolution: A new and updated passenger vessel safety briefing has been updated to comply with the requirements of 46CFR185.512, and will be read to the passengers prior going underway.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 January 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel was pushed onto the beach while anchoring and damage was reportedly sustained to propellers and rudder. Vessel to be hauled out and inspected for further damage by marine inspectors. Repairs to be conducted to attending marine inspector satisfaction prior to returning to service. 46 CFR 176.840
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2023
Resolution: Shaft repairs were satisfactorily made and a successful sea trial was completed in the presence of a marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 March 2022 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. COI was not posted. 46cfr176.302
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2022 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Letter was not posted. 46cfr176.306
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 March 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel missing FCC inspection.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 March 2022 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. 46cfr185.510
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
Resolution: Emergency instruction provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 March 2022 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Not posted at operating station. 46cfr184.506
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 March 2022 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Life Floats had no spacers. 46cfr180.137(f)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2022 Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces. Each stowage container for life jackets must not be capable of being locked. If practicable, the container must be designed to allow the life jackets to float free. Each life jacket kept in a stowage container must be readily available. Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Life jackets required proper stowage area so marked. 46cfr180.78
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 March 2022 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Battery installation was not secured to prevent movements but instead rested on top of aft steering space bilge pump. Mount properly. 46cfr183.350
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
Resolution: Battery inverter was properly mounted.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 16 March 2022 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel requires inspectors to observe fire and man overboard drills. 46cfr176.840
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 March 2022 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Container lacked labeling. 46cfr185.614
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2022
Resolution: Container marked distress signals.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 16 March 2022 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. Plan not in place. 33cfr151.57
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2022
Resolution: Garbage management plan submitted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 January 2022 Resolved
Contact cognizant OCMI to conduct new to zone inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2022

Casualty record · 1

16 January 2023Routine · role: Involved in a Marine Casualty · activity 7628989
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.