BARRACUDA

BARRACUDA is a 1979 offshore supply vessel. The Coast Guard has recorded 59 inspections since 1988, most recently in September 2026, along with 40 deficiencies and 1 casualty investigation in 2015.

Records from 1988 to 2026. Most recent: inspection, 9 September 2026.

Built
1979
Last inspected
9 September 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7942776 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDQ3962
168506
Flag
UNITED STATES
367627460
Maury page id
psix-168506

Inspections, by type

…with no type recorded4
Years with a record 31 calendar years (1988–2026)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)71.3 ft × 50.0 ft × 7.0 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)71.3 ft × 50.0 ft × 7.0 ft
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHARVEY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 July 2025 · expires 31 July 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Regulatory (Subpart C or D), Net Ton
92 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3962MMSI 367627460 · active · compulsorily equipped · granted 29 May 2025, expires 29 May 2035
WDH5387MMSI 367627460 · expired · compulsorily equipped · granted 14 June 2014, cancelled 17 August 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDC4900MMSI 367032520 · expired · compulsorily equipped · granted 9 April 2005, cancelled 13 June 2015
WDB7766MMSI 366947720 · expired · compulsorily equipped · granted 14 May 2004, cancelled 19 July 2014
WCP7374MMSI not assigned · cancelled · compulsorily equipped · granted 24 January 1995, cancelled 19 April 2001 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 59

9 September 2026 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8487612
4 September 2024 COI Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8016051
11 January 2023 Examination of Repairs · Internal Structural Exam · Welding Related Inspections Qualification Testing
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7627039
9 May 2022 Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7446580
6 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7191251
24 October 2019 Drydock Exam · COI Inspection · Internal Structural Exam · In-Service Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6838549
10 October 2019 Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6836691
20 December 2018 Annual Inspection · MTSA Verification · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6603601
17 October 2017 Annual Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6290983
9 December 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6053912
1 December 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5772898
9 November 2015 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5760498
8 November 2015 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5775403
15 June 2012 Inclining Experiment
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4352347
7 June 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4335582
9 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4307059
2 March 2010 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3687810
1 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3642413
16 December 2008 Re-Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3381974
21 November 2007 Hull Examination · Examination of Repairs · Ballast Water Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3120888
15 November 2007 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3099306
3 January 2007 Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2849292
23 November 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539846
8 November 2005 Ballast Water Examination · Hull Examination · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2530648
13 January 2005 Ballast Water Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2276538
15 December 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2260087
30 January 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1998912
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972239
15 October 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1689885
23 January 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1482465
4 October 2000 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369868
31 May 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049995
19 March 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 708668
14 February 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465534
12 February 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 153094
10 February 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212452
9 February 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464910
5 November 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404645
26 September 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364420
16 October 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448817
30 September 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 830636
14 September 1995 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355516
16 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1176385
6 December 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870219
3 November 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 864999
29 September 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456201
13 December 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1159635
10 November 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465119
11 September 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357960
2 September 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1270482
30 September 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934800
4 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905219
29 November 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1299864
20 September 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241270
16 February 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931666
4 January 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927865
5 December 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215292
27 December 1988 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 896644
27 December 1988 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1214547

Deficiency record · 40

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 June 2025 Resolved
...as appropriate for the intended voyage, each vessel must carry adequate and up-to-date...Charts of large enough scale to make safe navigation possible. During review of the vessel's Rose Point electronic navigational chart system, it was discovered that the program did not have a declaration of conformity required to verify compliance with electronic chart carriage standards. Vessel shall, within 30 days, ensure that if not properly maintaining paper charts and relying on electronic, the electronic chart system meets Radio Technical Commission for Maritime Services (RTCM) 1 class ‘A’.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2025
Resolved 7 July 2025
Resolution: Vessel updated electronic chart subscription of Coastal Explorer and showed evidence of Declaration of Conformity.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 9 May 2022 Resolved
VESSEL MUST BE IN SAFE AND SEAWORTHY CONDITION. FOUND POSSIBLE LEAKING THROUGH BOTTOM PLATE HULL IN ENGINE ROOMS / HOLE IN WATERTIGHT BULKHEAD SEPARATING ENGINE ROOMS. SUBMIT REPAIR PROPOSAL FOR BOTH AREAS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 May 2022 Resolved
RESCUE BOAT MUST BE IN PROPER CONDITION FOR OPERATION. FOUND CRACKS IN FUEL TANK; REPAIR / REPLACE ACCORDINGLY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2022
Resolution: Replaced fuel tank.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 May 2022 Resolved
VESSELS MUST PROVIDE ADEQUATE FIREFIGHTING WHEN LIFTING PORTABLE TANKS ON/OFF VESSEL. EDUCTOR WAS FOUND INOPERABLE; REPLACE ACCORDINGLY BEFORE CONDUCTING ANY OPERATIONS WITH PORTABLE TANKS ONBOARD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 May 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 May 2022 Resolved
EMERGENCY LIGHTING MUST ACTUATE UPON MAIN LIGHTING FAILURE. FOUND 01 E-LIGHT ON (02) DECK INOPERABLE; REPAIR / REPLACE ACCORDINGLY.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 16 May 2022
Resolution: Replaced light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 May 2022 Resolved
TWIST ON WIRE CONNECTIONS MUST BE IN AN ENCLOSURE / NOT BE USED TO SPLICE/EXTEND LENGTH OF CABLE. FOUND NUMEROUS CONNECTIONS NOT ENCLOSED, AS WELL AS DEAD END WIRING UNDER HELM CONSOLE. REMOVE / REPAIR ACCORDINGLY.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 18 May 2022
Resolution: Cleaned out and made permanent connections and wiring under helm console.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2022 Resolved
EACH BATTERY MARKED WITH AN EXPIRATION DATE USED IN AN ITEM OF SURVIVAL EQUIPMENT MUST BE REPLACED IF THE DATE HAS PASSED. PROVE ALL BATTERY DATES OF LIFERING LIGHTS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 16 May 2022
Resolution: Replaced batteries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2022 Resolved
MATERIALS IN PIPING SYSTEMS MUST CONFORM WITH ASTM-F 1201. FOUND NON-METALLIC FUEL STRAINERS ON ALL MDE AND GENERATORS. REPLACE ACCORDINGLY.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 16 May 2022
Resolution: Replaced filter bowls with metal conforming to ANSI standards.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 May 2021 Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition: shaft packing for port and starboard shafts must be adjusted to prevent excessive drop in engine rooms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
Resolution: Reattended the vessel and confirmed that shaft seals were tightened to prevent excessive leaking.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to provide services for safety under normal conditions; light bulb was missing in starboard engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
Resolution: Reattended the vessel and confirmed that a new light bulb was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew members from electrical hazards; dead end wires were found off of the starter for the starboard main propulsion prime mover.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2021
Resolution: Dead end wires were properly contained prior to the completion of the inspsection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
Each battery must be free from exposure to splash or spray of water; battery boxes for port generator and port main propulsion prime mover were filled with 02 inches of water.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2021
Resolution: Battery boxes were clear of water prior to the completion of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021 Resolved
If your vessel’s COI is renewed less often than annually, the Marine inspector must check the settings of relief valves on all pressure vessels twice every 5 years; proof of servicing relief device was not present on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
Resolution: Reattended the vessel and confirmed that newly installed relief devices had been installed with current servicing information.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 May 2021 Resolved
A vessel equipped with fixed pitch propellers must have on the navigating bridge and at the engine room control station a propeller speed and direction indicator for each shaft; port main engine tachometer was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
Resolution: Reattended the vessel and confirmed that shaft tachometer operated properly during propulsion check.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 May 2021 Resolved
Each vessel must be fitted with a compass suitable for the intended service of the vessel. Except aboard a vessel limited to daytime operation, the compass must be illuminated; compass light was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
Resolution: Reattended the vessel and confirmed that the magnetic compass light was operable.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 February 2020 Resolved
During operational testing of the fire pump, fire pump only had a pressure of 32 psi. Vessel was at the pier at minimum air gap. Vessel shall not sail until fire pump pressure can be verified by a attending Marine Inspector. 46cfr132.120(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 February 2020
Resolution: Fire Pump output was 60PSI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 February 2020 Resolved
Oily windings were found on the starboard generator and dusty/dirty windings were found on the port side generator. Clean both generator's windings and identify the source of the oil on the starboard generator and report findings to the attending USCG Marine Inspector. 46CFR127.220(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 February 2020
Resolution: Gens were cleaned and oil was from crank case breather(corrected).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 February 2020 Resolved
MI observed a power strip, open junctions boxes, and wire nuts that were not secure under the helm. On the STBD switch board MI observed a stuffing tube with an opening at the bottom of the switch board. Also in the STBD engine room the 36 Volt battery charger amp meter was not operating correctly. In the port engine room the DCV electrical connection on top were exposed.Vessel has 14 days to make repair to the attending MI. 46CFR129.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 18 February 2020
Resolution: electrical was in compliance
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2020 Resolved
MI inspector observed hydraulic leaks coming from the jacking system. Vessel has 14 days to make repairs to the attending USCG MI. 46CFR134.150(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 18 February 2020
Resolution: Leaks were fixed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 February 2020 Resolved
MI's identified wasted gasket on the 02 deck weathertight door. In addition, holes were found on the engine room watertight bulkhead. Make necessary repairs to the satisfaction of the attending USCG Marine Inspector. Vessel has 14 days to make repairs to the attending USCG MI. 46CFR127.230(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 18 February 2020
Resolution: new gasket was installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 February 2020 Resolved
Air Receiver has a MAWP of 200, a relief valve set at 150, and the pressure gauge is maxed out at 200. Gauge is required to be 1.2-2 times the setting of the relief valve. Replace gauge with a range of 300. Vessel has 14 days to make repairs to the attending USCG MI. 46CFR126.470 46CFR54.15-5(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 18 February 2020
Resolution: New gauge (300psi) was installed.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 20 December 2018 Resolved
Radios did not have reserve power when ship's power was secured. 46 CFR 80.860
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2019
Resolution: Reserved power 12v batteries were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 December 2018 Resolved
Excessive oil build up on starboard generator caused by missing blow by hose. Crew to clean engine, radiator, and install hose to bed pan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Engine cleaned and blow by hose routed to bilge area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 December 2018 Resolved
Starboard generator exhaust piping was leaking exhaust soot onto lagging. Crew to repair leak and clean lagging. 46 CFR 129.340
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Cleaned and exhaust piping clamp retightened.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 December 2018 Resolved
Electrical junction box in fiddley space bulkhead was covered with duct tape. Crew to repair. 46 CFR 129.340
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Obsolete junction box removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 December 2018 Resolved
Starboard generator switchboard hertz gauge was loose and hanging out of switchboard. Crew to repair. 46 CFR 129.330
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Switchboard gauge was installed correctly.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 20 December 2018 Resolved
Port rudder angle indicator was inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Rudder angle indicator was repaired.
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 January 2002 Resolved
Radar image unsat.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2002
Resolution: Serviced by technician.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 January 2002 Resolved
Port rudder room bilge alarm inop.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2002
Resolution: Repaired and retested.
Lifesaving › Hand Flares
Issued 23 January 2002 Resolved
Three orange smoke and four red flairs missing.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2002
Resolution: Replaced.
Construction/Loadline
Issued 14 February 2000 Resolved
Vessel is authorized to proceed under its own power from the Global dock atthe Port of Iberia tothe dock at MIF to affect permanent repairs to the vessel. Vessel may not operate until the renovation of the vessel has met to the satisfactionof the attending marine inspector.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Documentation
Issued 29 September 1994 Resolved
PROVIDE INDIVIDUAL VESSEL FCC STATION LICENSE AND CALL SIGN
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Unknown
Issued 5 December 1989 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL AND PROVIDE ON BOARD A COAST GUARDISSUED STABILITY LETTER.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Unknown
Issued 5 December 1989 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD/OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Unknown
Issued 27 December 1988 Resolved
INSTALL MONENTARY SWITCH FOR JACKING GEAR SYSTEM.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Unknown
Issued 27 December 1988 Resolved
PROVIDE APPROVED STABILITY/OPERATION MANUAL.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Unknown
Issued 27 December 1988 Resolved
PROVIDE RESCUE BOAR.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Unknown
Issued 27 December 1988 Resolved
PROVIDE ANCHOR AND LINE.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Unknown
Issued 27 December 1988 Resolved
INSTALL COAST GUARD APPROVED EPRIB.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Unknown
Issued 27 December 1988 Resolved
PROVIDE COASTR GUARD APPROVED PLANS FOR HULL STRUCTURE AND LEG STRUCTURES.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988

Casualty record · 1

8 November 2015Routine · role: Involved in a Marine Casualty · activity 5775403
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.