Records from 1989 to 2000. Most recent: inspection, 25 January 2000.
Documentation record
Registered dimensions (L × B × D)63.5 ft × 34.0 ft × 6.8 ft
Registered tonnagegross 69 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHALTER MARINE INC · CHICKASAW, AL, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 January 1992 · expires 31 January 2001
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Net Ton
69 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
25 January 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070627
18 October 1999
Initial Construction-Excluding Oversight
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1464885
2 December 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1375578
19 December 1997
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436012
1 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778037
16 December 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413095
7 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764979
24 June 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1083978
25 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 197684
30 November 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442323
13 December 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448605
13 September 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1176667
14 July 1994
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 455097
30 June 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 827095
30 November 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359673
18 November 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467828
14 January 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1266991
9 December 1991
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952572
22 November 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 951447
20 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910559
9 November 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919767
13 March 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922770
19 January 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925310
16 November 1989
Inclining Experiment · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240516
11 August 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1195613
Documentation
Issued 16 November 1989
Resolved
VESSEL TO BE READMEASURED TO LESS THAN 100 GROSS TON. IF OVER 100 GROSS TON, ADDITIONAL REQUIREMENTS WILL BE NEEDED AND MANNING INCREASED. MAIL NEW COPY OF CERTIFICATE OF DOCUMENTATION TO [name withheld].
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Documentation
Issued 16 November 1989
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Lifesaving
Issued 16 November 1989
Resolved
INSTALL A SUITABLE MEANS OF ESCAPE.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Fire Fighting
Issued 16 November 1989
Resolved
INSTALL OR REPAIR FIRE MAIN SYSTEM TO INCREASE PRESSURE.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Engineering
Issued 16 November 1989
Resolved
INSTALL AND TEST ENGINE ROOM BILGE ALARM(S) TO TO THE SATISFACTION OF A COAST GUARD INSPECTOR. ALARMS SHALL ACTIVATE ON BRIDGE AND BE MARKED AS APPROPRIATE.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Unknown
Issued 16 November 1989
Resolved
PROVIDE A MEANS ON THE BRIDGE, TO DETERMINE LOW PRESSURE OR LOSS OF HYDRAULIC PRESSURE TO JACKING MECHANISM.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Unknown
Issued 16 November 1989
Resolved
FINISH STENCILING ALL VENTS, ELECTRICAL PANELS, ETC.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Documentation
Issued 16 November 1989
Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Documentation
Issued 16 November 1989
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, FIRE CONTROL PLAN (IF VESSEL IS TO BE OVER 100 GROSS TON) AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989