Records from 2022 to 2026. Most recent: inspection, 23 April 2026.
Inspection history · 6
23 April 2026
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8354435
15 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8111959
30 April 2024
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7903781
20 April 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7668789
4 May 2022
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7442709
21 March 2022
Internal Structural Exam · Construction Oversight · COI Inspection · Hull Examination · Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7294680
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguisher brackets found in disrepair. Ensure portable extinguishers are safely mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 24 April 2025
Resolution: Bracket replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 April 2025
Resolved
The emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Confirm instructions match the specific configuration of the vessel and update as appropriate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 8 May 2025
Resolution: Received updated emergency instructions
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 May 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Instructions for fire were not specific to the vessel's configuration. Adjust instructions to match vessel arrangement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2024
Resolved 12 July 2024
Resolution: Vessel updated emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly portable fire extinguisher inspections are not being conducted nor recorded. Conduct and record monthly inspections.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2024
Resolved 1 May 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 20 April 2023
Resolved
At each inspection, the marine inspector may require that an abandon ship or man overboard drill be held. Unable to perform drills due to lack of crew. Drills must be completed prior to carrying passengers.
CITE
46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2023
Resolution: Completed satisfactory drills.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 April 2023
Resolved
Abandon ship, man overboard, and fire fighting drills and training shall be logged. The drill entry shall include the following information: General description of the drill scenario and training topics. Drills were logged but no details were provided. Vessel to update logs moving forward.
CITE
46 CFR 185.520(f)(2)
46 CFR 185.524(d)(2)
Action required: 10 - Deficiency Rectified
Resolved 20 April 2023
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 4 May 2022
Resolved
THE REGION OF THE VESSEL AFT OF THE SIDE DOORS, INCLUDING THE ENTIRETY OF THE AFT BENCH, SHALL BE BLOCKED OFF FROM PASSENGERS TO THE SATISFACTION OF THE [name withheld] THE AREA FOR ANOTHER VESSEL IT WAS OBSERVED THAT THE CHAINS USED TO BLOCK OFF THE AREA FROM PASSENGERS HAD BEEN CHANGED FROM THE ORIGINAL ACCEPTANCE. VESSEL SHALL SECURE THE CHAINS IN A SATISFACTORY CONDITION TO THE OCMI AND MAKE PERMANENT.
THIS MEASURE IS ALLOWED FOR THE PERIOD OF 3 MONTHS (SET TO EXPIRE 04 AUG 22) TO PERMIT SUFFICIENT TIME TO ADDRESS DEFICIENCY 02.
CITE: 46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2022
Resolution: Area is satisfactorily blocked off and in correct location.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 4 May 2022
Resolved
SUBMIT WEIGHT MOMENT CALCULATIONS SHOWING THE LIGHTSHIP CHANGES RELATIVE TO THE ISLAND VIBES (SISTER VESSEL)CONSIDERING ANY CHANGES RELATIVE. SUBMIT ALSO A REVISED GENERAL ARRANGEMENT AND STABILITY CALCULATIONS AS OUTLINED BY MARINE SAFETY CENTER TO THE VESSEL MANUFACTURER.
CITE:46 CFR 176.840
Action required: 705 - Other - as specified
Due 18 August 2022
Resolved 8 August 2022
Resolution: Calculations were submitted. Vessel has updated stabilty letter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022
Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects.
CITE: 46 CFR 183.354 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 20 May 2022