Records from 2022 to 2025. Most recent: inspection, 1 December 2025.
Documentation record
Registered dimensions (L × B × D)40.7 ft × 13.8 ft × 5.8 ft
Registered tonnagegross 21 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOAST GUARD YARD · BALTIMORE, MD, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT SCHUYLER, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
1 December 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8274877
10 September 2025
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8231029
27 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8070024
26 November 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8040041
28 March 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886529
16 January 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7850056
7 November 2023
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7806946
8 November 2022
Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7597822
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 December 2025
No resolution recorded
ON A VESSEL OF AT LEAST 7.9 METERS IN LENGTH, A VISUAL AND AUDIBLE ALARM MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE A HIGH WATER LEVEL IN EACH OF THE FOLLOWING SPACES: A MACHINERY SPACE BILGE, BILGE WELL, SHAFT ALLEY BILGE, OR OTHER SPACES SUBJECT TO FLOODING FROM SEAWATER PIPING WITHIN THE SPACE. MI OBSERVED ENGINE ROOM BILGE ALARM WIRED INCORRECTLY. COMPLETE REPAIRS PRIOR TO PAX.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 November 2024
Resolved
"A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years." Vessel will be passed due for Drydock & ISE (30NOV2024). Ensure DDX & ISE are completed.
46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2025
Resolution: Vessel began Dry Dock & ISE on 27JAN
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 November 2024
Resolved
"An existing vessel must comply with the requirements of this part except as otherwise specified by this section." Vessel is missing the 8-person IBA as dictated on the COI. Ensure vessel meets the required lifesaving.
46 CFR 180.15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 November 2024
Resolved
"(b) The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: (iv) The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted." Vessel did not have any records of service for portable fire extinguishers or fixed fire fighting system. Ensure servicing of the above is completed.
46 CFR 176.810(b)(1)(iv)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2025
Resolution: Verified onboard
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 26 November 2024
Resolved
"The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire." Vessel did not complete the required fire drills and crew trainings within the appropriate intervals. Ensure satisfactory drills and training are conducted with crew members
46 CFR 185.524(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2025
Resolution: Received record of Fire drill conducted onboard 27NOV24.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 November 2024
Resolved
"The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative." Vessel did not conduct monthly tests of EPIRB. Ensure monthly tests are completed.
46 CFR 185.728(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2025
Resolution: Vessel provided proof of monthly testing
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 November 2024
Resolved
"To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date." Vessel's registration with NOAA expired in OCT2024. Ensure EPIRB Test is properly registered.
47 CFR 80.1061(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2025
Resolution: Received records of EPIRB registration.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 March 2024
Resolved
A VESSEL CERTIFICATED TO OPERATE ON LAKES, BAYS, AND SOUNDS ROUTE WITHIN ONE MILE OF LAND IS NOT REQUIRED TO CARRY SURVIVAL CRAFT. DURING THE COLD WATER PERIOD, WHEN OPERATING BETWEEN NOVEMBER 01 TO THE FRIDAY PRIOR TO MEMORIAL DAY WEEKEND, VESSEL OPERATIONS ARE RESTRICTED TO LAKES, BAYS, AND SOUNDS WITHIN ONE (01) MILE OF LAND WHEN CARRYING GREATER THAN SIXTEEN (16) TOTAL PERSONS ON BOARD. ALL OTHER CONDITIONS OF VESSEL COI SHALL CONTINUE TO BE STRICTLY ADHERED TO.
705-C - RESTRICTING OPERATIONS - ROUTE DEPENDENT ON POB
46CFR180.207(d)
Action required: 705 - Other - as specified
Resolved 8 April 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 November 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must: ....... (3) Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and (4) Be installed in accordance with the manufacturer's instructions.
Vessels pre-engineered fixed gas extinguishing system failed to shut down engines and power ventilation. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2023
Resolution: RE-INSPECTED PRE-ENGINEERED FIREBOY SYSTEM SAT - MDE & MECH. VENTILATION SHUT-DOWNS & OVER-RIDE / RESTART ALL TESTED SAT.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 November 2023
Resolved
Vapor barriers. Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers.
Vessel has multiple penetrations located aft of the engine room through the bulkhead. 46 CFR 177.405(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 November 2023
Resolution: FIREPROOFING IN AFT BLKHD E/R INSPECTED SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023
Resolved
At each initial and subsequent inspection for certification .... make available for inspection all items in the ship's outfit, such as ground tackle, ... and equipment, markings, and placards, w...., as necessary to determine that they are fit for the service intended.
Prior to the use of the A-Frame davit, the vessel must
conduct a weight test. 46 CFR 176.816
Action required: 705 - Other - as specified
Resolved 11 September 2025
Resolution: Vessel provided weight test documentation.