Records in 2021. Most recent: inspection, 26 October 2021.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 28 September 2021
Resolved
Considering the deficiencies identified on the PSC Form B dated 28 September 2021 as objective evidence, the company has not established and carried out procedures as to ensure the ship’s material condition is in conformance with the provisions of the relevant rules and requirements. Concur with the Flag requirement for an external audit of the vessel’s SMS.
74SOLAS(20)IX/3.1
ISM 10.1-10.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 28 September 2021
Resolved 20 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 September 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The rescue boat forward compartment hatch was found cracked and improperly repaired with silicone. This inadequate repair enabled water to fill the entire forward compartment, directly effecting the seaworthiness and rescue capability of the rescue boat.
74SOLAS(20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 28 September 2021
Resolved 20 October 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2021
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. The electrical distribution power station located on the aft deck was found with internal electrical components falling out of the enclosure, feeder cables improperly secured, a severely wasted enclosure, and duct tape painted over in contrasting color to cover exposed wastage. In addition, the station was not properly locked-out/tagged out from its breaker. The tag was removed and no lock was installed. The existing condition of the power station poses an immediate threat to crewmember safety.
74SOLAS(04) II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 28 September 2021
Resolved 20 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 September 2021
Resolved
A Class divisions shall be so constructed as to be capable of preventing the passage of smoke and flame to the end of a standard one hour fire test. The identified A-0 boundary between the ROV Winch Room and the ROV Workshop has insulation removed and cables removed from the bulkhead penetration; leaving open gaps in the A-0 boundary.
74SOLAS(04)II-2/3.2.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2021
Resolved 20 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 September 2021
Resolved
Satisfactory means shall be provided for the protection of the crew in getting to and from their quarters and all other parts used in the necessary work of the ship. Elevated deck aft of the ship's house is missing deck grating and railings, presenting a significant fall hazard.
ICLL 66 1/25-41
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2021
Resolved 20 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2021
Resolved
Code: 09130
Machinery and associated piping systems and fittings shall be adequate for the service for which they are intended. Sewage tank vent pipe has a temporary soft-patch that is actively leaking.
74SOLAS(04)II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2021
Resolved 20 October 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 September 2021
Resolved
The condition of the ship and its equipment shall be maintained. Bilge alarms in vessel’s lower cargo space were found inoperable during testing.
74SOLAS(04)1/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2021
Resolved 20 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2021
Resolved
Code: 09130
No change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without the sanction of the Administration. A quick connect pipe coupling is installed on the AC chiller coolant line with a soft patch.
74SOLAS(04)1/11(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 20 October 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2021
Resolved
Code: 09110
Installation shall be such that electrical services essential for safety will be ensured under various conditions. The engine room watertight door proximity switch is missing and the cable servicing the switch was found coiled with bare wires exposed,not properly secured.
74SOLAS(04)II-1/40.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 20 October 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2021
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Multiple cables in ROV winch room and throughout main deck are not properly supported; held in place by temporary plastic zip-ties and rope installed without protection from mechanical damage, sharp bends around structures subject to chafing from vibration.
74SOLAS(04)II-1/45.5.5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 20 October 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2021
Resolved
Code: 021708
Electrical installations shall be such that the safety of crew and ship from electrical hazards shall be ensured. Vessel’s flow meter gen2 junction box not properly mounted. Plug Box 2-6 /1 internal components severely corroded. Engine room forward bulkhead outlet not properly mounted. L8.8F5 230.Vac junction box has cables pulled out.
74SOLAS(04)II-1/40.1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 20 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 September 2021
Resolved
Fittings shall be adequate for the service for which they are intended. The low level indicator sensor for a port side diesel tank was not properly mounted and the sight glass was held in place to the bracket with a cloth rag.
74SOLAS(04)II-1/26.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 20 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 September 2021
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Two of the six generator’s exhaust temperature sensors are disconnected rendering them inoperable.
74SOLAS(04)II-1/26.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 20 October 2021
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 28 September 2021
No resolution recorded
Code: 99101
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must: Remove fouling organisms from the vessels hull on a regular basis and dispose of any removed substances in accordance with local, State, and Federal regulations. Excessive marine growth on the vessels hull. Additionally, there is no record of anti-fouling coating from the last drydock. Current Antifouling certificate indicates that bottom paint has not been applied since 02 MARCH 2012.
33CFR151.2050(f)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 October 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 28 September 2021
Resolved
An annual survey within three months before or after each anniversary date of the IAPP shall be conducted. IAPP certificate has not been endorsed since March 14, 2020.
MARPOL 73/78 6/5.1.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 28 September 2021
Resolution: Provided IAPP with previous survey certified