MAURY USCG vessel records
← All vessels

ISLAND 5

ISLAND 5 is a public freight. The Coast Guard has recorded 1 inspection in 2021, along with 4 deficiencies — 4 with no resolution recorded —.

Records in 2021. Most recent: inspection, 21 September 2021.

Built
Not recorded
Last inspected
21 September 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 September 2021
…past their stated due date4
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9900590
J8B6176
1696938
Flag
SAINT VINCENT AND THE GRENADINES
Maury page id
psix-1696938

Documentation record

Tonnage as PSIX records it2277 - Convention (Subpart B), Gross Ton
683 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

21 September 2021 PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7317153

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 September 2021 No resolution recorded
(74 SOLAS (20) II-2/9.4.1.1.2)The construction of doors and door frames "A" class divisions, with the means of securing them when closed, shall provide resistance to0 fire as well as to the passage of smoke and flame equivalant to that of the bulkheads in which the doors are situatred. All doors to emergency exits in the engine room did not fully self-close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 21 September 2021 No resolution recorded
(74 SOLAS (20) III/18) A line-throwing appliance complying with the requirements of section 7.1 of the code shall be provided. No line-throwing devices were found on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 September 2021 No resolution recorded
(74 SOLAS (20) II-2/10.3.1 & FSS Code 4.2) Portable fire extinguishers shall comply with the requirements of the Fire Safety Sytems Code. All fire extinguishers shall be of approved types and designs based on the guidelines developed by the organization in Res.A.951(23). Records of inspection should be maintained. Portable fire extinguishers had no record of maintenance on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2021 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 21 September 2021 No resolution recorded
(74 SOLAS (20) III/19.3.6.1) Enclosed space entry and rescue drills should be planned and conducted in a safe manner, taking into account, as appropriate, the guidance provided in the recommendations developed by the Organization. No records of enclosed space drills on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2021 — due date passed with no resolution recorded

Ownership record