MAURY USCG vessel records
← All vessels

BALEEN

BALEEN is a 2020 tank ship. The Coast Guard has recorded 6 inspections since 2022, most recently in March 2026, along with 3 deficiencies and 1 operational control.

Records from 2022 to 2026. Most recent: inspection, 15 March 2026.

Built
2020
Last inspected
15 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9855367
V7A2740
1698627
Flag
MARSHALL ISLANDS
Maury page id
psix-1698627

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2022–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it54043 - Simplified, Gross Ton
54043 - Convention (Subpart B), Gross Ton
21124 - Simplified, Net Ton
82374 - Dead Weight, Ton
21124 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 6

15 March 2026 Deficiency Check · COC-CHEM Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8325618
2 November 2024 PSC B · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8028424
31 July 2023 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7756769
22 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7749312
6 March 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7646533
2 August 2022 PSC A · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7523044

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 15 March 2026 Resolved
Audible and visual alarms are to be initiated in the cargo control room, Navigation bridge and at the analyzing unit when vapor concentration in a given space reaches a pre-set value, which shall not be higher than the equivalent of 30% of the lower flammable limit. PSCO observed the crew unable to demonstrate an alarm above 5% LEL from any sample point tested. 74 Solas 20 II-2/4.5.7.3.1 FSS 16.2.2.3.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2026
Resolved 16 March 2026
Resolution: Submitted class report and videos demonstrating proper operation of the fixed gas detection cabinet.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 August 2022 Resolved
The high level alarm required must be identified with the legend "High-Level Alarm" in black letters at least 50.8 mm (2") on a white background. The "High level Alarm" was not marked appropriately.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 15 August 2022
Resolved 9 August 2022
Resolution: Provided pictures attesting to the completion of required marking.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 August 2022 Resolved
The tank overfill alarm required must be identified with the legend "Tank Overfill Alarm" in black letters at least 50.8 mm (2") on a white background. The "Tank Overfill Alarm" was not marked appropriately.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 15 August 2022
Resolved 9 August 2022
Resolution: Provided pictures attesting to the completion of required marking.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.