Records from 2021 to 2026. Most recent: inspection, 1 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
1 May 2026
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8358841
3 November 2025
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8259749
4 May 2025
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8123911
30 October 2024
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8027137
2 June 2024
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7925042
19 May 2024
Deficiency Check · COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7913063
29 April 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7905734
5 November 2023
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7820277
21 May 2023
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7690327
28 March 2023
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7798952
13 November 2022
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7591507
22 February 2022
COC-CVE Initial · Ballast Water Examination · PSC A · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7398694
11 August 2021
COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 7311796
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 May 2026
Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. The aft, port side Royal Promenade glass doors serving as the primary emergency escape route were incapable of opening. Impeding the ability to safely escape to the embarkation deck.
74SOLAS(20)II-2/13.1.2
15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 1 May 2026
Resolution: Crew rectified prior to USCG debarkation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 May 2026
Resolved
Doors and door frames in “B” class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. The B-15 door leading into the Hospital was not able to close and latch, compromising the structural fire integrity of the boundary.
74SOLAS(20)II-2/9.4.1.2.1
15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 1 May 2026
Resolution: Crew rectified prior to USCG debarkation.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 May 2026
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The markings must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be photoluminescent material or marked by lighting. The low location lighting was blocked in portions of the Hospital by emergency go-carts and furniture.
74SOLAS(20)II-2/13.3.2.5.1
15ac
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 1 May 2026
Resolution: Crew rectified prior to USCG debarkation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 May 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Stowage of combustibles to include cardboard boxes and wooden crates were discovered in the port, central, and stbd steering gear rooms as well as the steering gear converter rooms (category 10 spaces).
74SOLAS(20)II-2/9.2.2.3.2.2
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 1 May 2026
Resolution: Crew rectified prior to USCG debarkation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 November 2024
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO discovered an emergency MGO storage tank with a capacity of 41.4 m3 in the emergency diesel generator room actively leaking. Approximately 2 oz of fuel was found on deck as a result of the leak. Corrected on the spot by tightening the bolts on the manhole cover.
74 Solas 20 II-2/4.1.1
Code 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 3 November 2024
Resolution: Tightened bolts to stop leak.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 May 2024
Resolved
04109 - Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. Crew assigned to the Solarium, Windjammer, and Giovanni galleys were unfamiliar with firefighting systems in to include suppression at the deep fat fryer, ducting, and securing of ventilation.
74 SOLAS 20 II-2/15.2.2.1
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2024
Resolved 2 June 2024
Resolution: PSCO attended the vessel, and verified vessel conducted training with all galley staff members for fire fighting systems. Questioned galley staff members and all found to be incompliance.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 19 May 2024
Resolved
04110 - Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. The commander from Life boat #9 could not demonstrate or explain the operation of the VHF radio, PA system, start up proceedures, nor launching equipment. Additionally, MES team #22 could not properly explain launching proceedures.
74 SOLAS 20 III/19.2.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 May 2024
Resolved 19 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 November 2023
Resolved
In addition to complying with the specific provision for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Structural fire protection missing in the A-60 deck above the theatre.
74 SOLAS 20 II-2/9.2.2.3.1
07101
10c
Action required: 10 - Deficiency Rectified
Due 6 November 2023
Resolved 6 November 2023
Resolution: Vessel installed new lagging in area, Class and CG were satisfied.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 5 November 2023
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. The second commander of LB #12 could not identify location or operation of the lifeboat batteries, nor basic operations of lifeboat engines.
74 SOLAS 20 III/19.2.1
04110
10c
Action required: 10 - Deficiency Rectified
Due 6 November 2023
Resolved 6 November 2023
Resolution: Crewmember was trained and demonstrated proper procedure for his duties to the satisfaction of Class and CG.