Records from 1985 to 2000. Most recent: inspection, 23 August 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
23 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821017
1 September 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 229595
28 July 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 69343
28 July 1999
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424788
25 June 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436224
5 October 1998
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 801666
2 September 1998
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 796862
6 August 1998
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1423063
3 July 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411503
13 June 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1453366
8 August 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357690
18 July 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430238
21 July 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380252
23 August 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1177919
2 August 1994
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1470395
2 November 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840640
5 August 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423802
22 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 827110
6 May 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944589
23 January 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1262209
22 February 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 907853
23 August 1990
Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 903972
11 June 1990
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232453
23 February 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1227159
5 January 1990
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233773
28 February 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887656
27 September 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1044720
2 June 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1201811
1 March 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1029750
6 January 1988
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1015805
16 March 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327030
21 August 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963230
14 March 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306764
15 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287596
Construction/Loadline
Issued 28 July 1999
Resolved
REPAIR AND PROVE OPERATION OF PORT GENERATOR ROOM VENT AND VENT CLOSURE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. SEE 46 CFR 176.700.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Construction/Loadline
Issued 28 July 1999
Resolved
REPAIR OR RENEW DAMAGED DECK RAILING LOCATED ON PORT SIDE OF VESSEL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. SEE 46 CFR 176.700.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Construction/Loadline
Issued 28 July 1999
Resolved
REPAIR CRACK LOCATED ON STARBOARD DECKHOUSE IN WAY OF MAIN DECK JUNCTURE ATSTEPS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Construction/Loadline
Issued 28 July 1999
Resolved
REPAIR HULL PLATING IN WAY OF 12" CRACK LOCATED ON THE PORT STERN WRAPPER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. SEE 46 CFR 176.700.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Lifesaving
Issued 25 June 1999
Resolved
04. STENCIL ENGINE ROOM EMERGENCY ESCAPES.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Engineering
Issued 25 June 1999
Resolved
05. MAKE STARTING AIR RECIEVERS AVAILABLE FOR CREDIT EXAMINATION.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Engineering
Issued 25 June 1999
Resolved
01. REPAIR OR REPLACE ALL MAIN ENGINE PILOT HOUSE GAGES.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Electrical
Issued 25 June 1999
Resolved
02. REPAIR A/C UNIT THERMOSTAT WIRING.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Fire Fighting
Issued 25 June 1999
Resolved
03. REPAIR ENGINE ROOM VENT CLOSURES.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Lifesaving
Issued 2 September 1998
Resolved
CONDUCT MAN OVERBOARD DRILL TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Lifesaving
Issued 6 August 1998
Resolved
SUPPLY PROOF OF A RESCUE PLATFORM BEING PUT ON BOARD AND A MANOVER BOARD DRILL BEING CONDUCTED TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Lifesaving
Issued 13 June 1997
Resolved
PROVIDE PROOF EPIRB IS REGISTERED WITH NOAA.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Accommodation/Occupational Safety
Issued 13 June 1997
Resolved
REPAIR GLASS IN AFT WHEELHOUSE.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Engineering
Issued 13 June 1997
Resolved
LOCATE & REPAIR EXHAUST LEAK IN PORT MAIN DIESEL ENGINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1997
Resolved 17 June 1997
Fire Fighting
Issued 13 June 1997
Resolved
REPAIR/REPLACE HANDLE TO FIRE MAIN IN GEN SET ROOM.
Condition: Unknown
Due 13 June 1997
Resolved 17 June 1997
Lifesaving
Issued 13 June 1997
Resolved
PROVIDE 5 LIGHTS FOR PFD'S; TOTAL PERSONS ON BOARD REDUCED TO 51 UNTIL REPAIRED.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Lifesaving
Issued 13 June 1997
Resolved
SECURE LIFE FLOATS TO COMMON PAINTER.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Lifesaving
Issued 13 June 1997
Resolved
PROVIDE 1 OAR FOR LIFE FLOAT.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Construction/Loadline
Issued 18 July 1996
Resolved
Weld various fractures in way of stanchion on potable water tank in engine room
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Engineering
Issued 18 July 1996
Resolved
Provide/make permanant repairs to salt water ejection piping to the inboardexhaust of port main deisel engine where erroded
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Construction/Loadline
Issued 18 July 1996
Resolved
Weld various fractures in forepeak
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Construction/Loadline
Issued 18 July 1996
Resolved
Properly mount bilge pump in engineroom
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Electrical
Issued 18 July 1996
Resolved
Provide blank for switchboard where open
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Construction/Loadline
Issued 18 July 1996
Resolved
Properly repack/seal wire penetration on starboard, forward engineroom bulkhead
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Engineering
Issued 2 August 1994
Resolved
FUEL TRANSFER HOSE MUST HAVE A STATEMENT OF THE HYDRO-TEST DATE.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Electrical
Issued 2 August 1994
Resolved
REROUTE PHONE AND EXTENSION CORD GOING THROUGH WATERTIGHT DOOR.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Fire Fighting
Issued 2 August 1994
Resolved
HAVE PORTABLE FIRE EXTINGUISHERS PROPERLY SERVICED.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Engineering
Issued 2 August 1994
Resolved
INSTALL PROPER FLAME SCREENS ON FORWARD FUEL VENTS.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Engineering
Issued 2 August 1994
Resolved
TIGHTEN VENT HOUSING ON PORT AFT FUEL VENT GOOSENECK.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Construction/Loadline
Issued 2 August 1994
Resolved
REPAIR HATCH DOOR HINGE TO GENERATOR ROOM.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Construction/Loadline
Issued 2 August 1994
Resolved
Install window on starboard side aft. Temporary water tight repair must be installed prior to vessel sailing
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Accommodation/Occupational Safety
Issued 5 August 1993
Resolved
RENEW SEWAGE HOLDING TANK DUE TO WASTEAGE.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Documentation
Issued 5 August 1993
Resolved
PROVIDE ONBOARD A VALID RADIO TELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Electrical
Issued 1 March 1988
Resolved
RENEW MAIN SWITCH BOARD AMMETER TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988
Documentation
Issued 1 March 1988
Resolved
PROVIDE PROOF OF A VALID CERTIFICATE OF DOCUMENTATION TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988
Fire Fighting
Issued 1 March 1988
Resolved
INSTALL AND TEST FIRE MONITOR ON NO. 1 GENERATOR ENSURING ALL GUARDS AND SAFETY DEVICES ARE IN PLACE TO THE STAISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988