Records from 2021 to 2026. Most recent: inspection, 26 May 2026.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2025
Resolved
Port and stbd vapor detectors are inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2025
Resolution: Ensured proper operation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2025
Resolved
Aft stbd high water alarm is not funtioning properly. There is no light and a faint audible alarm. Ensure there is an audible and visual alarm for high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2025
Resolution: Ensured proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2025
Resolved
There are no child PFDs onboard. Vessel is required 03 child PFDs. Vessel cannot carry persons weighing less than 90 lbs until 03 PFDs are onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 13 June 2025
Resolution: Ensured 03 life preservers onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2025
Resolved
Stbd main emergency fuel shutoff remote has a broken bracket and is not allowing remote to close valve. Repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2025
Resolution: Ensured proper operation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 June 2025
Resolved
Ensure there is a portable light at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 14 June 2025
Resolution: Flashlight confirmed at op station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2024
Resolved
Prove proper operation of stbd laz electric bilge pump. Automatic funtion is not operational.
Action required: 10 - Deficiency Rectified
Resolved 3 June 2024
Resolution: vsl crew was able to get automatic pump operational
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 June 2024
Resolved
Ensure battery terminal on Hypu is covered.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 3 July 2024
Resolution: covered
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 3 June 2024
Resolved
Provide waste management plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 3 July 2024
Resolution: provided
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 3 June 2024
Resolved
Label sewage discharge valve "Do not open within 3 NM of shore."
Action required: 10 - Deficiency Rectified
Due 3 July 2024
Resolved 3 June 2024
Resolution: corrected onsite
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 3 June 2024
Resolved
Provide valid wave height table at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 3 July 2024
Resolution: provided
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 16 November 2023
Resolved
The lightship and full load displacements of the vessel as determined by the stability test exceeed the values by which the structural adequacy of the design was calculated. Submit revised structural calculations reflecting the change in displacements to the Marine Safety Center in acoordance with 46 CFR 177.340.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2023
Resolved 22 January 2024
Resolution: received updated restrictions table, updated COI
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2023
Resolved
Place in J-box or remove dead end wire in stbd fresh water tank space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 6 June 2023
Resolution: removed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 May 2023
Resolved
Install interconnected fire detection that meets UL217.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 6 June 2023
Resolution: installed and tested sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 May 2023
Resolved
Develop crew firefighting and emergency egress training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 6 June 2023
Resolution: provided
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 May 2023
Resolved
Ensure crew firefighting and emergency egress drills are logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 6 June 2023
Resolution: logged
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 May 2022
Resolved
Master of the vessel is to show proof of holding a valid FCC radio operators permit.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 13 May 2022
Resolution: Master showed proof of having a valid FCC radio operator permit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2022
Resolved
Provide proper labeling of fuel shutoff valve for the starboard forward heater tank.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 31 May 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 May 2022
Resolved
Provide proper markings of "DO NOT BLOCK" at both the port and starboard side emergency escape hatch locations.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 31 May 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 May 2022
Resolved
Provide proper posting of the EAP hotline numbers on or accessible within the vessel.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 31 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 12 May 2022
Resolved
Post the significant wave height and speed chart from the COI at the operating station.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 31 May 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 31 March 2021
Resolved
FCC Operators permit now available for inspection. Provide FCC operators permit. 47 CFR 13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2022
Resolved 13 May 2022
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 31 March 2021
Resolved
Fuel shut off valve for the heating oil tank forward is not marked. Properly mark location of this valve. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2022
Resolved 31 May 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 March 2021
Resolved
Escape hatch markings missing words "KEEP CLEAR". Provide additional markings "KEEP CLEAR" for emergency escape scuttles. 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2022
Resolved 31 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021
Resolved
PFD stowage locations not properly marked. Properly mark PFD stowage locations. 46 CFR 185.604(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2022
Resolved 12 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 March 2021
Resolved
Employee Assistance Program (EAP) phone number not provided/posted. Provide/post EAP phone number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2022
Resolved 31 May 2022