SALACIA is a freight ship. The Coast Guard has recorded 2 inspections since 2021, most recently in September 2025, along with 3 deficiencies — 1 with no resolution recorded —.
Records from 2021 to 2025. Most recent: inspection, 15 September 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it27331 - Convention (Subpart B), Net Ton 81094 - Dead Weight, Metric Ton 94796 - Displacement, Metric Ton 44015 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
15 September 2025PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8234495
5 October 2021PSC A · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7327621
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 15 September 2025Resolved
When transporting a solid bulk cargo which is liable to emit a toxic or flammable gas, or cause oxygen depletion in the cargo space, an appropriate instrument for measuring the concentration of gas or oxygen in the air shall be provided together with detailed instructions for its use. Such instrument shall be to the satisfaction of the administration. Manufacturer's requirements for the vessel's portable gas meters are required to be bump-checked with the recommended calibration gas prior to each use. The vessel has not have calibration gas on board the vessel since March 2025. Vessel is currently loaded with coal requiring gas detection and has loaded cargoes requiring gas detection since March 2025. Vessels safety management system does not list the meter found on board the vessel.
74SOLAS(24)VI/3.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 September 2025
Resolution: Received class report attesting to proper span gas being provided on board.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 September 2025No resolution recorded
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. The technical and/or operational nature of the deficiencies noted in deficiencies 01 and 03 provide objective evidence of a failure of the implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency.
74SOLAS(24)IX/3.1
ISM Code 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 September 2025Resolved
Where a solid bulk cargo is specifically listed in appendix 1 to this Code, it shall be transported in accordance with the provisions in its schedule in its schedule. All electrical cables and components situated in cargo spaces and adjacent enclosed spaces are free from defects. Such cables and electrical components are safe for use in an explosive atmosphere or positively isolated. The vessel's safety management system (4.1.3.10) states "It is essential that any fixed hold lightning system are isolated, or the fuses removed when the holds contain cargo." PSCO observed on the deck walk that the cargo hold lighting was not isolated. Crew isolated after being made aware of the situation. PSCO additionally observed that the securing of electricity to the holds is not addressed in Vessel Form Manual Section 7.
74SOLAS(24)VI/1-2
IMSBC 1.3.1
Action required: 10 - Deficiency Rectified
Resolved 16 September 2025