MAURY USCG vessel records
← All vessels

PERSEUS STAR

PERSEUS STAR is a 2021 tank ship. The Coast Guard has recorded 8 inspections since 2023, most recently in February 2026, along with 2 deficiencies.

Records from 2023 to 2026. Most recent: inspection, 17 February 2026.

Built
2021
Last inspected
17 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2023–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9891684
V7A4501
1702390
Flag
MARSHALL ISLANDS
Maury page id
psix-1702390

Documentation record

Tonnage as PSIX records it64305 - Convention (Subpart B), Gross Ton
35248 - Convention (Subpart B), Net Ton
116027 - Dead Weight, Metric Ton
137088 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

17 February 2026 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8311625
18 July 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8189052
18 December 2024 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8048850
26 September 2024 COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8006209
18 July 2024 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7965313
21 March 2024 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7882761
7 November 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7821605
2 September 2023 PSC A · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7777412

Deficiency record · 2

04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 September 2023 Resolved
Fire drills should be planned in such a way the due consideration is given to regular practice in the various emergency(s)that may occur depending on the type of ship and the cargo. Crew had not had a drill recorded in the laundry room, resulting in failure twice of a fire drill. Rectify deficiency prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2023
Resolved 3 September 2023
Resolution: Received DNV report. Drills were completed successfully as witnessed by class surveyor, who additionally issued PR17 to report failure of vessel's SMS to address the laundry room in fire drill rotation.
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 2 September 2023 Resolved
The alarms required in paragraphs 2.2.4.5.1.1, 2.2.4.5.1.3, and 2.2.4.5.1.5 shall be fitted in the machinery and cargo control room. Inert gas alarms did not sound as required in the cargo control room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 September 2023
Resolved 2 September 2023

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.