SOLAR SUSIE

SOLAR SUSIE is a 2021 tank ship. The Coast Guard has recorded 6 inspections since 2021, most recently in August 2024, along with 4 deficiencies.

Records from 2021 to 2024. Most recent: inspection, 8 August 2024.

Built
2021
Last inspected
8 August 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 August 2024
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2021–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9898515
1704941
Flag
LIBERIA
Maury page id
psix-1704941

Documentation record

Tonnage as PSIX records it30259 - Convention (Subpart B), Gross Ton
49360 - Dead Weight, Ton
13566 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

8 August 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7971297
17 May 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7686780
16 April 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7432180
30 March 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7421588
13 November 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7350255
1 November 2021 Administrative Inspection · COC-CHEM & TVE Renew
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7343421

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2023 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with IEC 60092-502. Found 24V DC valve position indicator (forward double block and bleed valve on N2 line) to not be gastight. 74 SOLAS (2020) II-1/45.11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 31 May 2023
Resolution: Received Class report attesting to the satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2023 Resolved
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with IEC 60092-502. Found 24V DC pressure sensors (2 located downstream from N2 double block and bleed) to not be appropriately in the cable connection gland. 74 SOLAS (2020) II-1/45.11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 31 May 2023
Resolution: Received class report satisfactory to clear the deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 November 2021 Resolved
Acceptable types of water seals includes the wet & semi-wet type. Other types of seals may be accepted as a case by case basis if approval is given by the Marine Safety Center. Vessel is equipped with a double block & bleed type non return device that is not approved by the USCG Marine Safety Center. 46CFR32.53-10(b)(1) Action: 50c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 14 December 2021
Resolution: Vsl recieved type approval from MSC.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 November 2021 Resolved
A fixed fire detection and fire alarm system shall be installed in periodically unattended machinery spaces. The vessel's fire detection system is displaying an error for Loop 3, rendering the vessel's reliability on fire detection inadequate for an unmanned engine space. 74 SOLAS (20)II-2/7.4.1 Action: 50abc
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 14 December 2021
Resolution: Technician repaired;class attestation of system operation.