SOLAR SUSIE
SOLAR SUSIE is a 2021 tank ship. The Coast Guard has recorded 6 inspections since 2021, most recently in August 2024, along with 4 deficiencies.
Records from 2021 to 2024. Most recent: inspection, 8 August 2024.
- Built
- 2021
- Last inspected
- 8 August 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9898515 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5XD2
1704941
Flag
LIBERIA
—
Maury page id
psix-1704941
Inspections, by type
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it30259 - Convention (Subpart B), Gross Ton
49360 - Dead Weight, Ton
13566 - Convention (Subpart B), Net Ton
49360 - Dead Weight, Ton
13566 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
8 August 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7971297
17 May 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7686780
16 April 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7432180
30 March 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7421588
13 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7350255
1 November 2021
Administrative Inspection · COC-CHEM & TVE Renew
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7343421
Deficiency record · 4
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2023
Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with IEC 60092-502. Found 24V DC valve position indicator (forward double block and bleed valve on N2 line) to not be gastight.
74 SOLAS (2020) II-1/45.11
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2023
Resolved
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with IEC 60092-502. Found 24V DC pressure sensors (2 located downstream from N2 double block and bleed) to not be appropriately in the cable connection gland.
74 SOLAS (2020) II-1/45.11
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 November 2021
Resolved
Acceptable types of water seals includes the wet & semi-wet type. Other types of seals may be accepted as a case by case basis if approval is given by the Marine Safety Center. Vessel is equipped with a double block & bleed type non return device that is not approved by the USCG Marine Safety Center.
46CFR32.53-10(b)(1) Action: 50c
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 November 2021
Resolved
A fixed fire detection and fire alarm system shall be installed in periodically unattended machinery spaces. The vessel's fire detection system is displaying an error for Loop 3, rendering the vessel's reliability on fire detection inadequate for an unmanned engine space.
74 SOLAS (20)II-2/7.4.1 Action: 50abc
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.