MAURY USCG vessel records
← All vessels

PRISM COURAGE

PRISM COURAGE is a 2021 tank ship. The Coast Guard has recorded 5 inspections since 2021, most recently in September 2025, along with 2 deficiencies.

Records from 2021 to 2025. Most recent: inspection, 3 September 2025.

Built
2021
Last inspected
3 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 September 2025
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2021–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9888481
3E3945
1704946
Flag
PANAMA
Maury page id
psix-1704946

Documentation record

Tonnage as PSIX records it97494 - Dead Weight, Metric Ton
133516 - Displacement, Metric Ton
122166 - Convention (Subpart B), Gross Ton
122166 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

3 September 2025 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8214923
5 September 2024 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7987711
17 September 2023 Administrative Inspection · COC-GAS Renew
Administrative · Liquefied Gas Carrier National Center of Expertise · Activity 7789309
21 November 2022 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7593209
4 December 2021 Deficiency Check · COC-GAS Renew · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7353727

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2021 Resolved
Where electrical equipment is installed in hazardous areas as provided in 10.2.3, it shall be selected, installed and maintained in accordance with standards not inferior to those acceptable to the organization. PSCO observed the certified safe electrical distrubution cabinets for the low duty and high duty compressor systems in the cargo compressor room are missing several approved blanks that have the same explosive protection rating of the equipment. CITE: 74 SOLAS (20) VII 13.1 IGC Code 10.2.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2022
Resolved 5 December 2021
Resolution: Onboard EX rated spare blanks were installed in place of the required stop glands with approval from the manufacturer and satisfactory installation was witnessed by class. A purchased order request for the required stop glands were placed on order.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2021 Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO observed the lighting fixture in GVU #2 has exposed wires where electrical cable connects to cable gland and GVU electrical terminal boxes in GVU #1 and GVU #2 are missing several blanks or stop glands with the required explosive protection rating. CITE: 74 SOLAS(20) VII 13.1 IGC Code 10.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2022
Resolved 5 December 2021
Resolution: Approved heat shrink wrap was installed and approved by class. Spare EX rated blanks were installed in place of the required stop glands with approval from the manufacturer and class. A purchased order request for the required stop glands were placed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.