BUTLER

BUTLER is a towing vessel. The Coast Guard has recorded 7 inspections since 2021, most recently in May 2026, along with 16 deficiencies.

Records from 2021 to 2026. Most recent: inspection, 7 May 2026.

Built
Not recorded
Last inspected
7 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 7 May 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2021–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1704990
Flag
UNITED STATES
Maury page id
psix-1704990

Documentation record

Tonnage as PSIX records it105 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

7 May 2026 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8368840
17 July 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8188898
18 June 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7939675
26 January 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7856068
3 August 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7759400
19 May 2022 Deficiency Check · Initial Certification
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7447442
18 October 2021 Initial Certification
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7337072

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 July 2025 Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in table 46 CFR 141.370 for specified areas where the vessel operates. RIVERS: 3 day / 3 night. Vessel missing 03 flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 21 July 2025
Resolution: Flares placed into service. 3day/3night
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 June 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided... Alarms must: have a means to test actuation at each operating station or have a coninuous self-monitoring alarm system which actuates if an alarm point fails or becomes disabled; (1) main engine RPM. RPM gauge in the pilot house was not functioning. Replace, or repair gauge, and show proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 31 July 2024
Resolution: RPM Gauge replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2023 Resolved
SWITCHBOARD HAS A BROKEN OFF CIRCUIT BREAKER LABEL. REPAIR OR REPLACE LABEL.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 8 August 2023
Resolution: SWBD circuit breaker has been relabeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2023 Resolved
ENGINE ROOM ELECTICAL PANEL NEEDS LABEL SHOWING ITS CURRENT AND VOLTAGE RATING.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 8 August 2023
Resolution: Engine room electrical panel as been labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2023 Resolved
2ND DECK ROOM, THE ELECTRICAL BOXES FOR THE "SEARCH [name withheld]" AND "32/12 VOLT BOX" HAVE UNUSED AND EXPOSED HOLES REQUIRING PLUGS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 8 August 2023
Resolution: Knock-out plugs have been inserted.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 August 2023 Resolved
VESSEL FIRE PUMP MUST BE SELF-PRIMING.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 18 September 2023
Resolution: Pump renewed with self priming pump.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 August 2023 Resolved
PROVIDE EVIDENCE THAT FIXED CO2 SYSTEM FLEXIBLE HOSES WERE TESTED DURING THE LAST MARKED CYLINDER TESTS. IF TEST WERE NOT COMPLETE, RETEST HOSES IN ACCORADENCE WITH REGULATION CITE OR REPLACE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 31 August 2023
Resolution: CO2 system hoses have been serviced.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 August 2023 Resolved
VESSEL HIGH BILGE ALARM HAS NO AUDIBLE SOUND AT OPERATING STATION.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 8 August 2023
Resolution: Witnessed video evidence of alarm working properly with visual and audio.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 August 2023 Resolved
FIRE DETECTION PANEL HAS NOT BEEN INSPECTED OR TESTED IN THE LAST 12 MONTHS. HAVE SYSTEM INSPECTED OR TESTED AS PER MANUFACTURERS MANUAL.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 24 August 2023
Resolution: Fire Detection System has been serviced by Cintas.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2023 Resolved
ELECTRICAL PANEL IN OPERATING STATION HAS OPEN CIRCUIT BREAKER SLOTS THAT REQUIRE BLANK COVERS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 8 August 2023
Resolution: Blank covers have been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2023 Resolved
A/C OUTLET IN OPERATING STATION NEEDS A COVER/FACE PLATE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 8 August 2023
Resolution: Face plate has been installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 August 2023 Resolved
VESSEL IS NOT RECORDING ALL REQUIRED ITEMS LISTED IN CITE FOR THEIR TVR. SEE 46 CFR 140.915(a) FOR LIST OF ALL REQUIRED ITEMS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 26 January 2024
Resolution: Vessel has started recording required TVR items.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 August 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 23 August 2023
Resolution: Vessel has replaced entire first aid industrial kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 August 2023 Resolved
VESSEL HAS NO LIFE JACKETS. PROVIDE FOR EACH PERSONS ONBOARD AS PER COI. INCLUDE LIGHT, WHISTLE, VESSEL NAME STENCILED ON JACKETS.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 August 2023
Resolution: Vessel now has required number of approved life jackets as per COI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 August 2023 Resolved
VESSEL HAS NO VISUAL DISTRESS SIGNALS WITH RIVERS ROUTE, VESSEL REQUIRES 3 DAY AND 3 NIGHT DISTRESS SIGNALS AS APPROVED UNDER 46 CFR 141.375 PARAGRAPHS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 7 August 2023
Resolution: Vessel now has distress signals for route on COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2023 Resolved
BOTH RING BUOYS WITH WATERLIGHTS HAVE TOO SHORT OF LANYARDS. ENSURE BOTH WATERLIGHTS ARE SECURED AROUND THE BODY OF THE LIFE RING BUOYS WITH LANYARDS AT LEAST 3 FEET BUT NO MORE THAN 6 FEET.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 8 August 2023
Resolution: Waterlight lanyards are now 3-6 feet long.