MAURY USCG vessel records
← All vessels

BBG GUILIN

BBG GUILIN is a 2021 freight ship. The Coast Guard has recorded 2 inspections since 2021, most recently in January 2024, along with 1 deficiency.

Records from 2021 to 2024. Most recent: inspection, 11 January 2024.

Built
2021
Last inspected
11 January 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 January 2024
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2021–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9922249
1705573
Flag
LIBERIA
Maury page id
psix-1705573

Documentation record

Tonnage as PSIX records it20155 - Convention (Subpart B), Net Ton
61189 - Dead Weight, Metric Ton
34584 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

11 January 2024 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7843025
23 December 2021 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7371906

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 December 2021 Resolved
74 SOLAS(20)II-2/14.2.2.1 Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of firefighting systems and appliances PSCO observed that crew was not able to open door to CO2 room. After several attempts resulting in breaking the lock, access was obtained.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 23 December 2021
Resolution: PSCO verified crew obtained access to CO2 room

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.